Preferred Language
Articles
/
Khbi5okBVTCNdQwCKY5c
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystals when their optic axes were fixed in the opposite direction relative to the optic axis of the original BBO crysta

View Publication
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Sensing and differentiation between normal flora and pathogenic of E.coli Bacteria using 410 nm diode laser
...Show More Authors

Abstract: Background: Optical biosensors offer excellent properties and methods for detecting bacteria when compared to traditional analytical techniques.  It allows direct detection of many biological and chemical materials.  Bacteria are found in the human body naturally non-pathogenic and pathologically, as they are found in other living organisms.  One of these bacteria is Escherichia coli (E. coli) which are found in the human body in its natural and pathogenic form. E.coli bacteria cause many diseases, including Stomach, intestines, urinary system infections, and others. The aim of this study: is sensing and differentiation between normal flora and pathogenic E.coli. Material and method:

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 28 2012
Journal Name
Rafidain Journal Of Science
Photodynamic Effect on Photosensitized Candida albicans with Hematoporphyrin Derivative Using Low Power Diode Laser In Vitro
...Show More Authors

View Publication
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Effects of 650 nm Diode Laser and 532 nm Frequency-Doubled Q-Switched Nd:YAG Laser on The Growth of Candida albicans, With and Without Photosensitizers
...Show More Authors

This work describes an experimental setup to evaluate the photodynamictoxicity of 650 nm diode laser and 532 nm Frequency-doubled Q-Switched Nd:YAG laser on the growth of Candida albicans as well as the potential fungicidal effect when combining the laser irradiation with specific photosensitizers namely methylene blue, toluidine blue, acridine orange and safranin O. In this study the findings showed that the number of colony-forming units per millilitre (CFU/ml) of C. albicans decreased with increasing exposure time. In particular in the case of the frequency doubled Nd:YAG laser combined with safranin O, the best lethal effect occurred at 11 minutes exposure time with 2.26 J/cm² energy density (89.18% reduction) in comparison with the

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 30 2021
Journal Name
Iraqi Journal Of Science
The Effects of Optical Power of Semiconductor Laser on the Characteristics of Si-diode in an Exposed Device
...Show More Authors

     In this paper, we experimentally studied the effects of optical power of semiconductor laser on the electrical properties of silicon diode of an exposed device. The experimental results showed that the laser diode light of different optical powers (2, 3, and 4 mW) had effects on the silicon diode that are somewhat similar to those of thermal treatment. A shift in the current-voltage curve to the left side was also noticed, which led to a non-linear decrease of the barrier voltage of the diode by the effect of laser light. We also reveal a decrease by 344.8 nA/mW in the reverse saturation current of the silicon diode as a result of exposure to laser light. The forward resistance of the silicon diode decreased with

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Influence of 805 nm Diode Laser on Plasmid Content of Some Locally Isolated Escherichia coli and Proteus Mirabilis
...Show More Authors

This work aimed to investigate the effect of Diode laser 805 nm on plasmid DNA and RNA
contents of some Gram negative bacteria represented by Escherichia coli and Proteus mirabilis isolates
.Plasmid extraction was done using two methods (Salting out and CTAB method).Different powers and
pulse repetition rates for 805 nm Diode Laser were used to study this effect. Results revealed that the
plasmid profile of the two species were highly affected using (2, 3) W at different frequencies including
5and 10 kHz as compared with 1 kHz while plasmids were gradually disappeared at 1W, 10 kHz. In the
same time the shining of RNA was also decreased gradually then disappeared with increasing powers
especially at 2W and 10 kHz cau

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Congenital Club Foot Treated By Of Ponseti Method : A Short-Term Results
...Show More Authors

Background: Congenital club foot is a complex deformity of foot .It is a collection of different abnormalities, with different etiologies. Consequently, Severity varies with   difficulties in evaluating treatment strategies with outcome results. The treatment of congenital club foot remains controversial. Usually, the orthopedist's goal is to obtain anatomically and functionally normal feet in all patients.                                Objective: To asses short term follow up result of conservatively treated club feet in relation to the age of initial casting by Ponseti technique.           Methods :A cross sectional observational study with some comparative content done in Al-kindy

... Show More
Preview PDF
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Congenital Club Foot Treated By Of Ponseti Method : A Short-Term Results
...Show More Authors

Background: Congenital club foot is a complex deformity of foot .It is a collection of different abnormalities, with different etiologies. Consequently, Severity varies with   difficulties in evaluating treatment strategies with outcome results. The treatment of congenital club foot remains controversial. Usually, the orthopedist's goal is to obtain anatomically and functionally normal feet in all patients.                                Objective: To asses short term follow up result of conservatively treated club feet in relation to the age

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The effect of triggering on the output performance of diode direct face pumping for disc laser in pulse mode
...Show More Authors

The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.

View Publication Preview PDF
Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Energy Generation from Static Water Head Developed By Forward Osmosis
...Show More Authors

In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po

... Show More
View Publication Preview PDF