Background: different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of bacteria and histological examination revealed less inflammatory cells than Group 2. Group 2 show significant differences in plaque and gingival indices between the visits. Though scalpel remains the gold standard choice in gingivectomy but Diode laser may have some advantages over it.
BaTiO3 thin films have been deposited on Si (111) and glass substrates by using pulsed laser deposition technique. The films were characterized by using X-ray diffraction, atomic force microscope and optical transmission spectra. The films growth on Si after annealing at 873K showed a polycrystalline nature, and exhibited tetragonal structure, while on glass substrate no growth was noticed at that temperature. UV-VIS transmittance measurements showed that the films are highly transparent in the visible wavelength region and near-infrared region for sample annealing on glass substrate. The optical gap of the film were calculated from the curve of absorption coefficient (αhν) 2 vs. hν and was found tobe 3.6 eV at substrate temperature 5
... Show MoreThis study aims to evaluate the effect of low power a semi-conductor He-Ne laser 4 mw power with 635 nm length on the growth and cell viability of dermatophyte Trichophyton mentagophytes. For this study, skin samples of 22 patents were collecting; those patients were suffering from dematophytsis caused by the dermatophytes, three isolates were diagnosed in dermatophytes group were T. mentagophytes. Results showed that rays of semi-conductor laser with 635 nm wavelength of 4 mn power have affected the fungal growth T. mentagophytes (the ideal isolates) in sold media when exposed to laser radiation in different periods of 10-20 second duration, but the other two isolates gave negative results. The effects of He-Ne laser rays in dry w
... Show MoreIn this study, the plasma formed by the preparation of Se and Tin (Sn) using a Nd: YAG laser with a wavelength of 1064 nm in air, which was then studied using the technique of optical emission spectrum, was presented (OES).The laser-induced plasma parameters such an electron temperature (Te) were identified using two-ratio methods, using Stark broadening methods to determine the density of electrons (ne). According to the findings, there is a correlation between the amount of laser energy that is applied and the increase in the emission intensity of the spectral lines. In the case of Se plasma, an increase in laser energy causes a rise in the temperature of the electrons. While increasing the temperature of the elec
... Show MoreSummary
On one hand, laser medical systems are very useful in several medical fields. They are used for diagnosis and treatment. In addition, they are used in medical researches.
On the other hand, laser hazards may cause irreversible injuries, especially eye injuries. Therefore the safe use of medical laser systems is very important to protect the laser
operators who are always exposed to laser hazards, and also to protect patients treated by medical laser. This academic research was designed to achieve the safe use of laser medical systems in Iraqi hospitals by:
a- Knowing the basic laser concepts.
b- Concentrating on the responsibilities of the medical st
Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an
... Show MoreBackground: Carpal tunnel syndrome (CTS) is one of common peripheral nerve disorder which involves an entrapment neuropathy of the median nerve at the wrist which occurs either due to primary idiopathic cause or secondary to systemic causes. The diagnosis of CTS is clinical and supported by neurophysiological analysis. Surgical intervention is the main treatment modality.
Objective: The aim of the present study is to evaluate the effectiveness of low level laser therapy (LLLT) to treat mild – moderate CTS cases.
Pateients and methods: The study involves 60 symptomatic patients complaining of CTS were divided into two groups. Group A was subjected to real LLLT by Gallium – Arsenide (Ga-As) laser (904 nm), whereas group B was sub
A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account the power temporal variation throughout an incident laser pulse, (i.e. pulse shape, or simply: pulse profile).
Three proposed profiles are employed and results are compared with the square pulse approximation of a constant power.
In this paper, ferric oxide nanoparticles) Fe2O3 NPs( were synthesized directly on a quartz substrate in vacuum by pulse laser deposition technique using Nd:YAG laser at different energies (171, 201,363 mJ/pulse). The slides were then heated to 700o C for 1 hour. The structural, optical, morphological, and electrical properties were studied. The optical properties indicated that the prepared thin films have an energy gap ranging from 2.28 to 2.04 eV. The XRD results showed no lattice impurities for other iron oxide phases, confirming that all particles were transformed into the α-Fe2O3 phase during the heating process. The AFM results indicated the dependence of nanoparticles size o
... Show MoreIn this study, the effect of grafting with magnesium (Mg) ratios (0.1, 0.3, 0.5) on the structural and optical properties of cadmium oxide films (CdO) was studied, as these films were prepared on glass bases using the method of pulse laser deposition (PLD). The crystallization nature of the prepared membranes was examined by X-ray diffraction technique (XRD), which showed that the synthesis of the prepared membranes is polycrystalline, and (AFM) images also showed that the increased deformation with magnesium led to an increase in the grain size ratio and a decrease in surface roughness, as well as the absorption coefficient was calculated. And the optical energy gap for the prepared membranes, where it was found that the absorption coef
... Show MoreIn this work, lead oxide nanoparticles were prepared by laser ablation of lead target immersed in deionized water by using pulsed Nd:YAG laser with laser energy 400 mJ/pulse and different laser pulses. The chemical bonding of lead oxide nps was investigated by Fourier Transform Infrared (FTIR); surface morphology and optical properties were investigated by Scanning Electron Microscope (SEM) and UV-Visible spectroscopy respectively, and the size effect of lead oxide nanoparticles was studied on its antibacterial action against two types of bacteria Gram-negitive (Escherichia coli) and Gram-positive (Staphylococcusaurus) by diffusion method. The antibacterial property results show that the antibacterial activity of the Lead oxide NPs was
... Show More