Preferred Language
Articles
/
KRdvSY8BVTCNdQwCh2mV
Estimating total dissolved solids and total suspended solids in Mosul dam lake in situ and using remote sensing technique
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Tue May 01 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Evaluation of Electromagnetic Near-Field Measurement Technique as Non-Destructive Testing for Composite Structures
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Nov 01 2012
Journal Name
Ijcsi International Journal Of Computer Science
Implementing a novel approach an convert audio compression to text coding via hybrid technique
...Show More Authors

Compression is the reduction in size of data in order to save space or transmission time. For data transmission, compression can be performed on just the data content or on the entire transmission unit (including header data) depending on a number of factors. In this study, we considered the application of an audio compression method by using text coding where audio compression represented via convert audio file to text file for reducing the time to data transfer by communication channel. Approach: we proposed two coding methods are applied to optimizing the solution by using CFG. Results: we test our application by using 4-bit coding algorithm the results of this method show not satisfy then we proposed a new approach to compress audio fil

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Iraqi Journal Of Applied Physics
Highly-Pure Nanostructured Metal Oxide Multilayer Structure Prepared by DC Reactive Magnetron Sputtering Technique
...Show More Authors

In this work, metal oxides nanostructures, mainly, copper oxide (CuO), nickel oxide (NiO), titanium dioxide (TiO2), and multilayer structure were synthesized by dc reactive magnetron sputtering technique. The structural purity and nanoparticle size of the prepared nanostructures were determined. The individual metal oxide samples (CuO, NiO and TiO2) showed high structural purity and minimum particle sizes of 34, 44, 61 nm, respectively. As well, the multilayer structure showed high structural purity as no elements or compounds other than the three oxides were founds in the final sample while the minimum particle size was 18 nm. This reduction in nanoparticle size can be considered as an advantage for the dc reactive magnetron sputtering tec

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
A Case Report -Bilateral Giant Achilles Tendon Xanthomas Resection with a Tendon transverse Technique
...Show More Authors

Background : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition.

Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected.

There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficultie

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Al-kindy College Medical Journal
A Case Report -Bilateral Giant Achilles Tendon Xanthomas Resection with a Tendon transverse Technique
...Show More Authors

Background : Xanthomatosis is a disease in which large tendon tumors can occur, especially in the Achilles tendon. This disease is a rare interesting orthopaedic condition. Case Report:A case of a twenty eight year old girl patient with giant bilateral Achilles tendon xanthomas in which both tumors were resected. There was no ulceration on the both sides. The patient was treated by total resection of the lesion and reconstruction using tendon transfer of the Peroneus brevis and Flexor hallusis longus. Postoperative treatment consisted of six weeks lower leg cast immobilization followed by partial weight bearing. After 4 months the patient was able to walk pain free without any difficulties. It has been suggested that total resection with au

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
The optical properties of C\Mg, nano-rods produced by the explosion wire technique
...Show More Authors
Abstract<p>The aim of this research is to study the optical properties of carbon-magnesium plasma resulting from arc discharge with explosive wire technique, where the energy gap of each of carbon and magnesium and the carbon-magnesium bond for three values of the wire exploding current (50,75,100 amperes) was studied. It was found that the energy gap for each of carbon and magnesium decreases with increasing the current, the X-ray diffraction of magnesium and the carbon-magnesium suspension was studied, and FTIR of the carbon-magnesium suspended carbon was studied for three values of the exploding current (50, 75, 100 amperes) and the type of bonds for carbon and magnesium was determined. To ob</p> ... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Solution of 2nd Order Nonlinear Three-Point Boundary Value Problems By Semi-Analytic Technique
...Show More Authors

    In this paper, we present new algorithm for the solution of the second order nonlinear three-point boundary value problem with suitable multi boundary conditions. The algorithm is based on the semi-analytic technique and the solutions which are calculated in the form of a rapid convergent series. It is observed that the method gives more realistic series solution that converges very rapidly in physical problems. Illustrative examples are provided to demonstrate the efficiency and simplicity of the proposed method in solving this type of three point boundary value problems.

View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Solution of Nonlinear High Order Multi-Point Boundary Value Problems By Semi-Analytic Technique
...Show More Authors

In this paper, we present new algorithm for the solution of the nonlinear high order multi-point boundary value problem with suitable multi boundary conditions. The algorithm is based on the semi-analytic technique and the solutions are calculated in the form of a rapid convergent series. It is observed that the method gives more realistic series solution that converges very rapidly in physical problems. Illustrative examples are provided to demonstrate the efficiency and simplicity of the proposed method in solving this type of multi- point boundary value problems.

View Publication Preview PDF
Crossref
Publication Date
Thu Nov 01 2012
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Direct melanocytes transplant from normal donor area into vitiliginous recipient area by dermabrasion technique
...Show More Authors

KE Sharquie, AA Noaimi, HA Al-Mudaris, Journal of Cosmetics, Dermatological Sciences and Applications, 2012 - Cited by 6

View Publication
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
‘Peacock tail’ Clipping Technique for a Giant Middle Cerebral Artery Aneurysm: A Technical Note
...Show More Authors

Background: Giant middle cerebral artery (MCA) aneurysms are surgically challenging lesions. Because of the complexity and variability of these aneurysms, a customized surgical technique is often needed for each case. In this article, we present a modified clip reconstruction technique of a ruptured complex giant partially thrombosed middle cerebral artery aneurysm.

Case description: The aneurysm was exposed using the pterional approach. Following proximal control, the aneurysm sac was decompressed. Then, we applied permanent clips to reconstruct the aneurysm neck. The configuration of the aneurysm mandated a tailored clipping pattern to account for resi

... Show More
View Publication Preview PDF
Scopus Crossref