Preferred Language
Articles
/
KRbSQ4cBVTCNdQwClD_N
Gingival tissue samples from periodontitis patients demonstrate epithelial–mesenchymal transition phenotype
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Sep 01 2026
Journal Name
Molecular Genetics And Metabolism Reports
Acid sphingomyelinase deficiency: Phenotypic, biochemical, and molecular heterogeneity in a series of 47 Iraqi patients from a single center
...Show More Authors

Objectives Acid sphingomyelinase deficiency (ASMD) is an inherited autosomal recessive disease caused by pathogenic variants in the sphingomyelin phosphodiesterase-1 (SMPD1) gene, which encodes acid sphingomyelinase (ASM). ASMD has 3 broad phenotypes (type A, type A/B, and type B) characterized by the age of onset, symptomatology, and the rapidity of disease progression. The diagnosis of ASMD can be delayed or missed because of the wide spectrum of severity and its variable manifestations. Analysis of genotype-phenotype correlations can help to determine ASMD disease type and inform management. Here, we describe the clinical presentation of 47 patients with ASMD referred to a single center in Iraq since 2007, whose diagnosis was confirmed b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 12 2017
Journal Name
Iraqi Journal Of Laser
A Comparative Evaluation of Post-Operative Pain and Function after Gingival Depigmentation Using 940 Nm Diode Laser And Conventional Bur Method: 6 Months Study
...Show More Authors

The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
Effect of isovalent substitution and Quenching on the Transition Temperature of (Bi1-xPbx)2(Sr1-yBay)2Ca2Cu3O10+δ
...Show More Authors

A high Tc superconductor with a nominal composition
(Bi1-xPbx)2(Sr1-yBay)2Ca2Cu3O10+δ for (0 £ x £ 0.5) and (0 £ y £ 0.5) was prepared by
a solid state reaction method. The effect of the substitution of Pb for Bi and Ba for Sr and
quenching temperature on the superconductivity has been investigated to obtain the
optimum conditions for the formation and stabilization of the high Tc phase (2223).
The results showed that the optimum sintering temperature for the pure composition is
equal to 875°C and the sintering time is equal to 240h with heating and cooling rate of
60°C/h . Our results indicated that a small amount of (Ba = 0.1) could raise the transition
temperature (Tc), but enhancing Ba to 0.4 has raised

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2026
Journal Name
Journal Of Global Pharma Technology
Synthesis, Physiochemical and Thermal Study of Some Transition Metal Complexes with Chelating Ligand and Study their Theoretical Treatments
...Show More Authors

Complexes of Cr+3, Ni+2 and Cu+2 with the ligand 2-(p- nitrobenzoyl) thiobenzimidazol) (L) were prepared and characterized by FT-IR ,UV-Visible, TG analysis ,Atomic absorption spectroscopy , Molar conductivity and magnetic moments measurements .The general formula has been suggested for all the prepared complexes [Cr(L)2Cl2]Cl.4H2O, [Ni(L)2(H2O)2]Cl2.2H2O and [Cu(L)2(H2O)2]Cl2.2C2H5OH to be an octahedral geometry. A theoretical treatment of these compounds in gas phase was done using HyperChem.8.7 program. Semi –empirical PM3 method was performed to evaluate the ∆H° ƒ, ∆ Eb and ∆ET for all compounds, also vibration frequencies, electronic spectra and electrostatic potential HOMO and LUMO energies for the ligand was estimated to de

... Show More
Publication Date
Tue Sep 29 2026
Journal Name
Journal Of Kufa For Chemical Sciences
Evaluation of Oxidative Stress and Liver Function Parameters in the Sera Samples of Kufa Cement Factory Workers
...Show More Authors

AbstractThe objective of the present study was measured of several oxidative stresses and liver function parameters in workers occupationally exposed to cement dust in Kufa Cement Factory, in order to test the hypothesis that cement dust exposure may perturb these parameters. Assessment of oxidative stress and liver function parameters were performed in 63 workers occupationally, in different departments of Kufa Cement Factory, exposed to cement dust (range of the exposure time was 5-38 years) and 36 matched unexposed controls. The study results illustrated an increasing in the oxidative stress parameters, moreover; liver function parameters showed abnormal results in the exposed workers compared to the unexposed. An increase in theses para

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Engineering And Technology Journal
Kinetic Study and Determination of Some Insecticides in Soil Samples by Ultrasonic Extraction Followed by Gradient HPLC
...Show More Authors

Ultrasonic Extraction method followed by gradient HPLC was carried out for the simultaneous determination of four insecticides are [imidacloprid (Imi), thiamethoxam (Thi), indoxacarb (Ind) and abamectin (Aba)] used to combat the major insect pests in Iraq, whitefly, Dubas Bug, worms fruits as well as to combat the spiders – dream respectively in eco-soil samples. The extraction recovery was in the range of 99.77 to 109.1 %. The dissipation kinetics and residual levels of these insecticides in soil sample was studied under field ecosystem. The half-life of the mix insecticides was determined. The half-life was in range of 0.38 to 4.06 days with the soil samples were brought from the Agricultural Land called Nahrawan located in th

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Exposure and etching time effects on the fission track density in CR-39 detectors using teeth samples
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Effect of etching time on the track density of fission fragments human teeth samples with Lexan detector
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref