Preferred Language
Articles
/
KBfZbo8BVTCNdQwC7Xg3
Evaluating the Performance of Combined Equipment (RAU) and Field Tested
...Show More Authors
Abstract<p>An experiment was carried out evaluate the performance of RAU combined equipment under three levels of practical speed, (V1) 4.06 km. h<sup>-1</sup>, (V2) 4.43 km. hr<sup>-1</sup> and (V3) 5.76 km. hr<sup>-1</sup>, and three levels of depth with 10,20and 30 cm. It is denoted by D1, D2, D3 respectively. A split plot design was used within the RCBD design with three replications. The experiment results showed that the first practical speed 4.06 km.hr<sup>-1</sup> achieved the lowest slippage percentage from 9.61%, lowest traction power 14.65hp, lowest soil penetration resistance to1.34 kg.cm<sup>-2</sup>, and the highest total operating costs (40803.4 ID.ha<sup>-1</sup>, while the third speed achieved the opposite results. The first treatment depth achieved the lowest results for slippage percentage 8.52%, traction power 15.34hp, soil penetration resistance 1.17 kg. cm<sup>-2</sup>, and total operating costs 37215.0ID. ha<sup>-1</sup>, while the third depth achieved the opposite results. Interaction between treatment depth and practical speed showed that the first treatment depth with the first practical speed has the lowest average of slippage percentage 7.63%, the lowest value of the traction power 13.77 hp, and the lowest average of soil resistance to penetration 1.03 kg.cm<sup>-2</sup>, while the first treatment depth and third practical speed has lowest average of the operating costs 34533.4 ID.ha<sup>-1</sup>.</p>
Scopus Crossref
View Publication
Publication Date
Thu Jan 16 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Security and confidentiality of information and its impact on the competitive performance of insurance companies: A prospective study for the Iraq insurance company and ALhamraa Insurance company (private)
...Show More Authors

The security of information represent the available  protection of  information and its component and guaranty the its safety and confidentiality. The absent or lack or stop of security of information and without maximum benefit may lead to lose confidence and make it burden on the company. So we must protect the company and information from the damages which may lead to the frailer of performance and loses of the company and its workers. So the security of information considered one of the potential  and controlling basis to protect individuals and companies from the damages. To insure the security  and confidentiality of information there are delicate,  proper and trusted ways, like FIRE WALL, PASS WORD, SYPHAR

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 21 2025
Journal Name
Modern Sport
An analytical study of some of the deterministic variables of the stage of advancement and its relation to the accuracy of the performance of the skill of high jump correction
...Show More Authors

View Publication
Publication Date
Thu Jun 15 2017
Journal Name
Arab World English Journal
An Assessment of Iraqi EFL Learners’ Performance in Using Synonymy and Antonymy
...Show More Authors

The knowledge related with lexical items can be realized as including relations of meaning a cross words. Words that share a similarity of meaning are called to be synonymous, and words that share a contrary of meaning are called to be antonymous. Both of them are universal linguistic phenomenon that exist in terms of linguistic system of every language. The present study aims at finding out areas of difficulty that Iraqi EFL learners encounter in the use of synonymy and antonymy, both on the recognition and production levels. Also tries to detect the main reasons behind such difficulties. A diagnostic test of two parts, namely, recognition and production, is designed. The test is built to include two linguistic phenomenon which are: synony

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Optics
Performance analysis of optical communication networks utilizing optical fibers and OFDM technology
...Show More Authors

This document provides an examination of research, on combining orthogonal frequency division multiplexing (OFDM) and optical fibers in communication networks. With the increasing need for data speeds and efficient use of bandwidth experts have been exploring the connection between OFDM, valued for its ability to handle multipath interference and optimize spectral usage and optical fiber technology which provides superior data transmission capabilities with low signal loss and strong protection, against electromagnetic disturbances. The review summarizes discoveries from studies examining the pros and cons of using OFDM, in optical communication networks. It discusses obstacles like fiber nonlinearity, chromatic dispersion and the effects o

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Tue Sep 24 2019
Journal Name
Journal Of Engineering
Flexural Performance of Laced Reinforced Concrete Beams under Static and Fatigue Loads
...Show More Authors

This paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections ( ) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of them are casted with vertical shear reinforcement used as control beams) are tested under four points bending loading with displacement control technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to horizontal , and lacing steel rat

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 16 2017
Journal Name
Computers
Enhancing BER Performance Limit of BCH and RS Codes Using Multipath Diversity
...Show More Authors

View Publication
Scopus (11)
Crossref (7)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Influence of design anode and cathode channel on (PEMFC) fuel cell performance
...Show More Authors

View Publication
Scopus (16)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Study of Collector Geometry Effect on Solar Chimney Performance
...Show More Authors

There have been many advances in the solar chimney power plant  since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated  to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve go

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Civil Engineering Journal
Marshall Performance and Volumetric Properties of Styrene-Butadiene-Styrene Modified Asphalt Mixtures
...Show More Authors

The durability of asphalt pavement is associated with the properties and performance of the binder. This work-study intended to understand the impact of blending Styrene-Butadiene-Styrene (SBS) to conventional asphalt concrete mixtures and calculating the Optimum Asphalt Content (OAC) for conventional mixture also; compare the performance between SBS modified with the conventional mixture. Two different kinds of asphalt penetration grades, A.C. (40-50) and A.C. (60-70), were improved with 2.5 and 3.5% SBS polymer, respectively. Marshall properties were determined in this work. Optimum Asphalt Content (OAC) was 4.93 and 5.1% by weight of mixture for A.C. (40-50) and (60-70), respectively. Marshall properties results show an increasem

... Show More
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref