An experiment was carried out evaluate the performance of RAU combined equipment under three levels of practical speed, (V1) 4.06 km. h-1, (V2) 4.43 km. hr-1 and (V3) 5.76 km. hr-1, and three levels of depth with 10,20and 30 cm. It is denoted by D1, D2, D3 respectively. A split plot design was used within the RCBD design with three replications. The experiment results showed that the first practical speed 4.06 km.hr-1 achieved the lowest slippage percentage from 9.61%, lowest traction power 14.65hp, lowest soil penetration resistance to1.34 kg.cm-2, and the highest total operating costs (40803.4 ID.ha-1, while the third speed achieved the opposite results. The first treatment depth achieved the lowest results for slippage percentage 8.52%, traction power 15.34hp, soil penetration resistance 1.17 kg. cm-2, and total operating costs 37215.0ID. ha-1, while the third depth achieved the opposite results. Interaction between treatment depth and practical speed showed that the first treatment depth with the first practical speed has the lowest average of slippage percentage 7.63%, the lowest value of the traction power 13.77 hp, and the lowest average of soil resistance to penetration 1.03 kg.cm-2, while the first treatment depth and third practical speed has lowest average of the operating costs 34533.4 ID.ha-1.
This research aims to study the performance of operations to provide nursing services, which included dimensions (quality, timeliness, leadership skills, behavioral manifestations, relationships with others, problem-solving and decision-making, job performance) and its effects in nursing performance. The research to prove the value of the performance of service delivery processes dimensions by nursing staffs working in Iraqi hospitals, nursing and measuring performance. To find out the nature of nursing services, and a comparison between hospitals to measure the extent of the application dimensional among themselves, and that by relying on the dimensions of a global study, which was measu
... Show MoreAn experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show MoreNowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari
... Show MoreIschemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc99m MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo