Preferred Language
Articles
/
KBdUoo0BVTCNdQwCdRfo
Effect of surface treatment of zirconia-ceramic dental restorations
...Show More Authors

The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 150 zirconia specimens (discs, rods and crowns) were divided according to the type of surface treatments; Group M1 designated unsintered zirconia specimens coated with a mixture of glaze porcelain powder and partially-sintered zirconia powder prepared at 1100 °C with two particle sizes; A (26 ± 0.3 μm) and size B (47 ± 0.5 μm), group M2 was coated with mixture of ceramic liner paste and same selected particle sizes of partially-sintered zirconia powders. The coated groups (M1 and M2) subdivided according to powder sizes into M1A, M1B, M2A and M2B. APA group (as control) of sintered zirconia specimens abraded with 50 μm aluminium oxide powder. Surface area roughness (Sa) was measured by surface texture analyser. Surface morphology and elemental composition were analysed by scanning electron microscope (SEM). Crystallographic phases were identified by X-ray diffraction (XRD). The coefficient of thermal expansion (CTE) was assessed by a thermomechanical analyser. For shear bond strength (SBS) test was evaluated by a universal testing machine (UTM). The fracture strength (FS) test prepared and measured by Cercon CAD/CAM system and UTM. Fractographic analysis for SBS and FS were examined by a stereomicroscope and SEM. For each test and measurement, 10 specimens were used per group. Finite element analysis (FEA) was used to simulate and predict the iv stress distributions of the static oblique load in coated and non-coated zirconia crown models. The collected data were analysed by one-way ANOVA and Tukey HSD test at (P<0.05). Surface roughness results showed significant differences among all groups (P<0.000). The M1B group exhibited a higher Sa value (10.33 ± 0.59 μm) among the tested groups. XRD analysis showed tetragonal and monoclinic phases in the control group while only tetragonal was detected in the coated groups. The SBS values for coated groups were higher than the control group. The M1B group showed higher and significant differences in SBS value (37.54 ± 4.38 MPa) among other tested groups (P<0.05). The FS test indicated that coated M1B group (647.92 ± 97.33 N) higher than the other groups (P<0.00). FEA showed the coated crown models have lower stress level than the non-coated model. The new coating (M1B) by airbrush spray technique considered as an alternative way to APA treatment to improve the bond strength of zirconia substrate to veneering ceramic and indicating as an applicable surface treatment for improving the clinical performance of the coated ZCR.

Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Effect of Cryogenic Treatment on the Properties of Low Carbon A858 Steel
...Show More Authors

This study is concerned with the effect of Deep Cryogenic Treatment (DCT) at liquid nitrogen temperature (-196 o C) on the mechanical properties and performance of low carbon steel (A858). The tests specimens were divided in to two groups, the first group was subjected to the conventional heat treatment of normalizing, and the second group was also normalized then subjected to (DCT). The results have shown that after (DCT), the Hardness, Tensile properties and the impact energy absorbed were all slightly increased. However the fatigue test showed some positive improvement in fatigue limit by 20(N/mm2 ), and the volume wear rates at different loads were significantly decreased after (DCT). The changes in microstructure due to (DCT) were c

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technolog
Effect Of heat Treatment On The Optical Properties Of CuInSe2 Thin Films
...Show More Authors

CuInSe2(CIS) thin films have been prepared by use vacuum thermal evaporation technique, of thickness750 nm with rate of deposition 1.8±0.1 nm/sec on glass substrate at room temperature and pressure (10-5) mbar. Heat treatment has been carried out in the range (400-600) K for all samples. The optical properties of the CIS thin films are been studied such as (absorption coefficient, refractive index, extinction coefficient, real and imaginary dielectric constant) by determined using Measurement absorption and transmission spectra. Results showed that through the optical constants we can make to control it are wide applications as an optoelectronic devices and photovoltaic applications.

View Publication
Publication Date
Thu Jan 07 2016
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect Of heat Treatment On The Optical Properties Of CuInSe2 Thin Films
...Show More Authors

CuInSe2 (CIS)thin films have been prepared by use vacuum thermal evaporation technique, of 750 nm thickness, with rate of deposition 1.8±0.1 nm/sec on glass substrate at room temperature and pressure (10-5) mbar. Heat treatment has been carried out in the range (400-600) K for all samples. The optical properties of the CIS thin films are been studied such as (absorption coefficient, refractive index, extinction coefficient, real and imaginary dielectric constant)by determined using Measurement absorption and transmission spectra. Results showed that through the optical constants we can made to control it is wide applications as an optoelectronic devices and photovoltaic applications.

Preview PDF
Publication Date
Sat Jun 07 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Oral Health Status and Treatment Needed in Relation to Dental Knowledge, Among a Group of Children Attending Preventive Department, College of Dentistry, University of Baghdad
...Show More Authors

Background: Oral health represents an important base for human well-being; the heath of the body begins from oral cavity. Great deal has been applied to increase knowledge in the field of oral health in order to develop appropriate preventive program. This study was conducted in order to estimate the percentage and severity of dental caries and gingivitis among children attending Preventive Department in Collage of Dentistry, University of Baghdad and to determine dental treatment need for those patients, further more to study the relation of these variables with dental knowledge. Materials and Methods: The study group consists of 163 children with an age ranged from 6 to 14 years, who attended the preventive clinic for the first time to be

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
The impact of histopathological celiac disease activity on dental enamel defects and dental caries
...Show More Authors

Background: Celiac disease is an autoimmune chronic disease that affects the human’s intestine and subsequently reflects its effect on the entire body health by retardation the absorption and immune mediated complications cause the involvement of oral health. The present study intended to evaluate the impact of the histopathological disease activity upon dental enamel defects and dental caries.

Subjects and methods: Forty celiac-diseased patients aged 7-11 years were collected from 3 different teaching hospitals in Baghdad classified by means of the histopathological activity of the intestinal disease according to modified Marsh-Ros

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Research Journal Of Pharmacy And Technology
Electro-polymerization of poly eugenol on ti and ti alloy dental implant treatment by micro arc oxidation using as anti-corrosion and anti-microbial
...Show More Authors

In this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at

... Show More
View Publication
Scopus (25)
Crossref (10)
Scopus Crossref
Publication Date
Sat Jun 07 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Caries-Experiences and Dental Treatment Needs among (16-18 Years Old) in High School Girls in Al-Mussayb City, Babylon Governorate
...Show More Authors

Background: Numerous epidemiological studies were conducted in Iraq, concerning dental caries and related etiological factors however; most of these studies were concerned with pre-and primary school children and/or those at index ages (12-15years old). At the time studies regarding older ages are very limited. This study was done to determine the prevalence and severity of dental caries and treatment need among high schools girls (16-18 years old) in Al-Mussayb city, Babylon Governorate. Thus, it can be considered as a base line data that allows studying dental caries among permanent dentition, also allows the comparison with other studies in other parts of the world. Material and Method: A total number of 900 high school girls were examin

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival microleakage of composite restorations with different bonding protocol in class II cavity treated with chlorhexidine (an in-vitro study)
...Show More Authors

ABSTRACT Background: One of the challenges to use chlorhexidine is its effect on the amount of microleakage after restoration; however, use of the materials with antibacterial properties after tooth preparation and before restoration has been widespread. The objective of this, in-vitro, study was to evaluate the influence of consepsis (chlorhexidine gloconate disinfectant) application on microleakage in class II cavities restored with light cured composite using universal adhesive system; etch and rinse technique –self etch technique. Materials and Methods: Forty class II cavities were prepared on mesial and distal surfaces of 20 non-carious mandibular third molars. The cavities were divided into four groups; (n =10 for each group).

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Current Medical Science
Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias
...Show More Authors

View Publication
Crossref (16)
Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The effect of disinfectants on the surface quality of irreversible hydrocolloid impression material and gypsum cast
...Show More Authors

Objective: To evaluate the changes in the surface quality of irreversible hydrocolloid impression material
hydrogum following disinfection with 0.525% sodium hypochlorite, 0.2% Chlorehexidine Gluconate, and 4%
Povidone Iodine.
Methodology: Forty specimens of alginate impression materials hydrogum were fabricated according to the
ISO 1563 and were divided into four groups according to the method of solution dipping: group 1: Dip in
0.525% sodium hypochlorite, group 2: Dip in 0.2% chlorhexidine gluconate, Group 3: Dip in 4% Povidone Iodine,
Group 4: No treatment with any solution (control group). Then the specimens were poured in type II stone.
Surface detail was determined using a stainless steel block in accordance w

... Show More
View Publication Preview PDF