Background: This study aimed to determine the amount of fluoride in commercially available bottled drinking water in Al-Basra city, Iraq Materials and Methods: Eleven brands of bottled drinking water were obtained from supermarkets in Al-Basra city, Iraq. Five samples of 10 ml. were taking from each one of brands and the fluoride was determined by using fluoride ion selective electrode. Results: The highest fluoride concentration was present in BADIOT brand (1.174 mg/L) while the lowest was in Barakat brand (0.038 mg/L). One way ANOVA test showed a highley significant difference among different commercially branded types. Coclusions: Bottled water available in Al-Basra city contains less concentration of fluoride ion than normal values
... Show MoreThe presnty study included physical , chemical and phycological study of choosen one station in Habbaniya lake to investigat the diurnal variation at each hour along the 24 hours . Water temperature showed clear variations and coincided with the air temperature of study , Habbaniya Water was alkaline with pH more than 7 without clear diurnal variations . Conductivity , Total hardness , Calcium and Magnesium values showed no clear varitions . Chloride and Salinity values appeared relatively stable . The data showed a relative increasing in Dissolve oxygen values during the night hours.On the other hand the alkalinity and acidity values were unstable during the 24 hours of the study. According to the quantitative s
... Show MoreAbstract A descriptive study was conducted in Al-Bashir teaching hospital in Amman city from 15th May 2004 to 15th August 2004 , in order to "Assess the adult asthmatic patients’ quality of life (QOL). Objective: This study aimed at identifying the domains of (Environmental, Physical, Daily Living Activity, Drug and Medication, Psychological , and Social), Methodology : A Purposive (Non-Probability) sample of (100) adult asthmatic patients visited the emergency department and outpatient clinic of chest department in Al-bashir hospital .A Questionnaire was constructed for the purpose of the study, and compris
Abstract. In this research, the uranium concentration in (16) water samples collected from some agricultural areas surrounded with AlTuwitha nuclear site in Baghdad-Iraq was measured by using a CR-39 detector. The concentration of uranium in this study was from (0.6 ± 0.33mg/l) to (2.51 ± 0.49 mg/l), and the weighted average for the concentrations (1.262 ± 0.402 mg/l). The results showed it is a concentration of uranium level in water samples studied is higher than the allowed limit recommended by WHO and ICRP.
Water supply and distribution networks play an important role in our daily activities. They make a substantial contribution to public health by providing potable water for public consumption and non-potable applications such as firefighters and other purposes such as irrigation. This study used ArcMap 10.8 and WaterGEMS CONNECT Edition update 1 version to create a hydraulic network model to simulate the pipes’ network. Detailed network information, including pipe lengths, layouts, and diameters, was given by the Baghdad Water Department. The TUF-2000H Handheld digital ultrasonic flow meter has been used to measure the water flows in the network’s source nodes. In eight junctions,
Polyimide/polyaniline nanofiber composites were prepared by in situ polymerization with various weight percentages of polyaniline (PANI) nanofibers. X-ray diffraction (XRD) and Fourier transform infrared spectra (FT-IR), proved the successful preparation of PANI nanofiber composite films. In addition, thermal stability of PI/PANI nanofiber composites was superior relative to PI, having 10 % gravimetric loss in the range of 623 °C to 671 °C and glass transition temperature of 289 °C to 297 °C. Furthermore, the values of the loss tangent tanδ and AC conductivity σAC of the nanocomposite films were notably higher than those of pure polyimide. The addition of 5 wt.% to 15 wt.% PANI
This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagno
... Show MoreThis study was done to find the effect of Tigris-Therthar channel on the water quality of Tigris River to face the climate change which causes decreasing in water resources, in addition to decreasing in its quality. Nine stations were chosen located on Tigris River, Tigris-Therthar channel, Groundwater, and Therthar lake. The results indicated that the TDS increased in summer season, and the effect of Tigris-Therthar cannel was limited, also the effect of groundwater was limited, but there was an indication refers of possibility of increasing these effects on the quality of water. The study recommends observing the Tigris River through a programme to identify any change in water in future.