At atmospheric pressure and at a frequency of 9.1 kHz, a constructed magnetically stabilized tornado gliding arc discharge (MSGAD) system was utilized in this study to generate a non-thermal plasma with an alternating voltage source from 2,4,6,8 to 10 kV. Argon gas was used to generate the arc plasma with an adjustable flow rate using a flow meter regulator to stabilize the gas flow rate to 2 L/min. A gliding plasma discharge is achieved by a magnetic field for the purpose of a planned investigation. The influence of the magnetically stabilized tornado gliding arc discharge parameters such as magnetic field and applied voltage on microscopic tornado plasma parameters was studied. The electron temperature1was measured using a Boltzmann plot and the electron1density was1determined by the Stark1broadening method. The electron temperature ranged from 0.818 eV to 1.495 eV, and the electron density varied from 1.37 × 1018 cm−3 to 2.49 × 10 18 cm−3 at a magnetic coil with 350 turns. Subsequently, the electron temperature increased to a range of 1.029 eV–1.794 eV, and the electron density reached a range of 1.53 × 1018 cm−3 to 2.89 × 1018 cm−3 at a magnetic coil with 500 turns. It can be observed that the plasma properties exhibit a rise as the number of turns of the coil and the applied voltage increase. © 2023
The ability of microorganisms to attach to living and non-living surfaces and create a biofilm is the cause of numerous long-lasting illnesses, as well as their strong resistance to drugs. Bacterial biofilms consist of intricate assemblies of immobile bacteria. These are located in an extracellular matrix and adhere to various surfaces for a long period. The present study evaluated the antibacterial effectiveness of Plantago major extract against Staphylococcus aureus biofilm. The specimens analyzed in this investigation were skin infections of clinical origin. The current study was not previously studied, particularly in terms of S. aureus biofilm breakdown and inhibition. The disc diffusion method was used to test the antimicrobial activi
... Show MoreElbow stiffness is hard to treat and commonly resulted from trauma or degenerative arthritis. This study aimed to demonstrate the effectiveness of using ultrasound therapy in management of stiff elbow joint resulted from several etiological factors. A total number of 42 patients (35 male and 7 female) allocated randomly from the Department of Physiotherapy at Al-yarmouk Teaching Hospital during 2013. Each patient examined physically by physiotherapist taking in consideration the measurement of the joint movement angle using goniometer in flexion and the extension, and the pain score using visual analogue scale (VAS). Ultrasound therapy initiated thrice weekly for two weeks. At the time of entry, the means degree of flexion and extension
... Show MoreBetween October and December 2018, 27wounds and burn swab specimens were collected by laboratories at Al-Yarmook hospital, and cultured on Mannitol salt agar. the isolate was subjected to Nd: YAG laser in different power (400mJ, 500mJ, 800mJ and 900mJ). In general the laser showed effect on bacterial growth that reach to complete killing, the statistical analysis showed that there is weak correlation between laser at 400mJ with killed percentage. While in 500mJ its exhibit complete correlation with killing percentage, this correlation was decreased with increasing in power to 800mJ and 900Mj.
n this work, the effect of gamma rays on blood thinning drugs was studied using the drug (Aspirin), where gamma rays were spread with the drug using a radioactive source (Co60), and 15,000 grams of Aspirin were placed in the device (gamma chamber 900). The drug was subjected to different irradiation doses (5 KGy, 10 KGy, 15 KGy) and the amount of absorption of the drug was observed in the gamma for different doses and the study of x-rays. After confirming the absorption of the drug to radiation, the effect of the drug on blood thinning was calculated using the rat model and compared with the same drug and the same dose but without exposing the drug to radiation and comparing all results with the control group. The way drugs absorbed radiati
... Show MoreA laboratory experiment was carried out according to a completely randomized design with four repetitions on the seeds resulting from a field experiment applied for the two seasons, 2020 and 2021, to find out the effect of the cultivars (Ambar 33, Yasamin, Dijlah, Ambar Al-Baraka and Furat 1) and the harvest dates (at physiological maturity and after 7 and 14, 21 and 28 days of physiological maturity) on the vigour of rice seeds. The results showed the superiority of the seeds of the cultivar Anbar Al-Baraka at first and final counting, dry weight of the seedling, seedling vigor index and electrical conductivity, and the superiority of the seeds of Dijla cultivar at accelerated aging test and cold test without significant difference with th
... Show MoreThe aim of this research is to study the effect of high concentrations of salts, pressure and temperature on the performance of the RO membrane with time. Four different (Na2CO3) concentrations (5000, 15000, 25000 and 35000) ppm and various pressures such as (1, 3 and 5) bars at different temperatures of the feed solution (i.e., 25, 35 and 45) ◦C were used in this work. It was found that, as the concentration of salt and feed temperatures increase, the rejection of the salt decrease. While the salt rejection of the membranes increases with increase of transmembrane pressure.
This paper studies the effects of stiffeners on shear lag in steel box girders with stiffened flanges. A three-dimensional linear finite element analysis using STAAD.Pro V8i program has been employed to evaluate and determine the actual top flange stress distribution and effective width in steel box girders. The steel plates of the flanges and webs have been modeled by four-node isoparametric shell elements, while the stiffeners have been modeled as beam elements. Different numbers (4, 8, and 15) for the steel stiffeners have been used in this study to establish their effects on the shear lag and longitudinal stresses in the flange. Using stiffeners reduced the magnitude of the top flange longitudinal stresses about 40%, but did
... Show More