This paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT), parabolic half cut twisted tape (PCT), and triangular cut twisted (VCT) of twist ratio= 2.93 and cut depth= 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO2/water nanofluids. Typical twist tape with twist ratio of= 2.93 was used for comparison. The results show that the heat transfer was enhanced by increasing of Reynolds number and nanoparticles concentration of nanofluid. The results have also revealed that the use of twist tape enhanced the heat transfer coefficient significantly and maximum heat transfer enhancement was achieved by the presence of triangular cut twist tape insert with 2% volume concentration of SiO2nanofluid. Over the range investigated, the maximum thermal performance factor of 5.13 is found with the simultaneous use of the SiO2nanofluid at 2% volume concentration VCT at Reynolds number of 220. Furthermore, new empirical correlations for Nusselt number, friction factor, and thermal performance factor are developed and reported.
Klebsiella pneumoniae causes lethal nosocomial infections, mostly affecting patients with severe burns. More than 80% of its isolates have shown resistance to routinely used antibiotics in parallel with increased infection rates. The study aimed to determine the molecular typing and genetic relatedness of K. pneumoniae. Therefore, 20 multidrug resistant (MDR) K. pneumoniae already isolated from infected burned wounds in two major hospitals of Al-Kut city east Iraq were subjected to genotyping analysis. The random amplified polymorphic DNA (RAPD)-based polymerase chain reaction (PCR) technique was used along with three oligonucleotide primers (P13, OPX-04, and OPY-01). The amplicons’ patterns of the electrophoresis-gel were analyzed by the
... Show MoreThe characteristic feature of a structure is that it accepts changes in form; this fact gives the structure features represented by the unity of its parts and wholeness. Accordingly, structure theorists consider the structure the major factor in composing the parts within the wholeness of the visual cognition according to a methodological adaptation of the creative processes in treating the elements of the logo, and this would make the logo have a visual identity that provides the recipient with a holistic description of the content of the materialistic representation. Additionally, the logo achieves identification between the concept and the reality at many times; therefore, it represents an entity that has characteristics and mean
... Show MoreBackground: Prevention against nosocomial infection is an important issue of health care field and considered a challenge of patients’ since it reflects its effect on their quality of life. This due to that it will lead in most cases to prolonged hospitalization and also more cost.Objective: To determine the prevalence of different types of nosocomial infection and to demonstrate the association of different risk factors (hospital environment, workers, visitors) with nosocomial infection.Patients: this study was carried out in eleven months at Ba’quba general Hospital; Iraq. A total of 81 clinical specimens (urine, pus from abscess , burn swab, nasal swab, ear swab and wound swab) taken from surgical patients,102 specimens from
... Show MoreThe present work concerns with simulating unsteady state equilibrium model for production of methyl oleate (biodiesel) from reaction of oleic acid with methanol using sulfuric acid as a catalyst in batch reactive distillation. MESHR equations of equilibrium model were solved using MATLAB (R2010a). The validity of simulation model was tested by comparing the simulation results with a data available in literature. UNIQUAC liquid phase activity coefficient model is the most appropriate model to describe the non-ideality of OLAC-MEOH-MEOL-H2O system. The chemical reactions rates results from EQ model indicating the rates are controlled by chemical kinetics. Several variables was studied such as molar ratio of methanol to oleic acid 4:1, 6:1
... Show MoreIn this paper we use non-polynomial spline functions to develop numerical methods to approximate the solution of 2nd kind Volterra integral equations. Numerical examples are presented to illustrate the applications of these method, and to compare the computed results with other known methods.
Background: The prediction of changes in the mandibular third molar position and eruption is an important clinical concern because third molar retention may be beneficial for orthodontic anchorage. The aims of this study were to assess the mandibular third molar position by using medical CT scan and lateral reconstructed radiograph and evaluate gender differences. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years who were attending at Al-Suwayra General Hospital/ the Computerized Tomography department. The distance from anterior edge of ramus to distal surface of permanent mandibular second molar and mesio-distal width of developing mandibular third molar were
... Show MoreCoated sand (CS) filter media was investigated to remove phenol and 4-nitrophenol from aqueous solutions in batch experiments. Local sand was subjected to surface modification as impregnated with iron. The influence of process variables represented by solution pH value, contact time, initial concentration and adsorbent dosage on removal efficiency of phenol and 4-nitrophenol onto CS was studied. Batch studies were performed to evaluate the adsorption process, and it was found that the Langmuir isotherm effectively fits the experimental data for the adsorbates better than the Freundlich model with the CS highest adsorption capacity of 0.45 mg/g for 4-nitrophenol and 0.25 mg/g for phenol. The CS was found to adsorb 85% of 4-nitrophenol and
... Show Morelar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag