The use of blended cement in concrete provides economic, energy savings, and ecological benefits, and also provides. Improvement in the properties of materials incorporating blended cements. The major aim of this investigation is to develop blended cement technology using grinded local rocks . The research includes information on constituent materials, manufacturing processes and performance characteristics of blended cements made with replacement (10 and 20) % of grinded local rocks (limestone, quartzite and porcelinite) from cement. The main conclusion of this study was that all types of manufactured blended cement conformed to the specification according to ASTM C595-12 (chemical and physical requirements). The percentage of the compressive strength for blended cement with 10% replacement are (20, 11 and 5) % , (2 , 12 and, 13) % and (18, 15 and 16) % for limestone , quartzite and porcelinite respectively at (7,28 and 90)days for each compare to the reference mix, while blended cement with 20% replacement are (-3, -5 and -11) ,(6, -4% and -5) and (6, 4 and 6) % for limestone , quartzite and porcelinite respectively at (7, 28 and 90)days compare to the reference mix .The other mechanical properties (flexural tensile strength and splitting tensile strength) are the same phenomena of increase and decrease in compressive strength. The results indicated that the manufacture Portland-limestone cement, Portland-quartzite cement and Portland-porcelinite cement with 10% replacement of cement with improvable mechanical properties while the manufacture Portland-porcelinite cement with 20% replacement of cement with slight improvable mechanical properties and more economical cost.
In this study, concentrations of radon were measured for seventeen samples of soil distributed in three Sulphuric Spring, in addition to other regions as a background in Hit City in AL-Anbar Governorate. The radon concentrations in soil samples measured by using alpha-emitters registration that emits from radon (222Rn) in (CR-39) track detector. The concentrations values were calculated by a comparison with standard samples. The results show that the radon concentrations in first spring varies from (258.253- 347.762 Bq/m3), second spring (230.374-305.209 Bq/m3), third spring (292.002-336.023 Bq/m3) and the average radon concentration in other regions (187.821 Bq/m3). As a conclusion of the study radon concentration in Sulphuric Spring is r
... Show MoreThe modern teaching methods, and their importance in achieving the desired learning goals for the individual and the society, have been addressed, as it is necessary to develop the methods, ways and strategies used in the process of teaching the intermediate stages in the various fields in general and the field of physical education in particular, the importance of research is the effect of using the strategy of similarities in teaching some basic skills of basketball for students of the second intermediate. As for the problem of research, the researcher mentioned the lack of use of teachers’ strategy method similarities in the educational units because of its importance, and after study and analysis the researcher found it necessary to i
... Show MoreAssessing performance efficiency is critical to the management need for oversight, planning, and continuous periodic evaluation of the multiple activities of Northern Cement State Company in order to determine the level of achievement of the objectives set, and to correct the deviations and delays that the evaluation shows and limitation of liability. What cannot be measured cannot be managed. The aim of this research is to highlight the impact of using BSC, financial and non-financial, to give comprehensive and clear picture of the company's performance and to measure the quality of its performance by using six-sigma and the level of deviations in achieving the planned goals. Therefore, four-key hypotheses were formulated for th
... Show MoreThe aim of this study to determine the genetic distance and relationship among some Iraqi date palm cultivars by using the Random Amplified Polymorphic DNA (RAPD) technique. Molecular analysis was performed by using 10 random primers. These primers produced 176 fragment lines across 14 cultivars, Of these, 166 or 94.3% were polymorphic. The size of the amplified bands ranged between 200-2250 bp. The genetic polymorphism value of each primer was determined and ranged between 7.5-16.9%. In terms of unique banding patterns, the most characteristic banding pattern was for the Barhee cultivar with primer OP-M06 and for the Khadhrawy Mandily cultivar with primer OP-C02. Genetic distance values ranged from 0.868 to 0.125 among studied date palm
... Show MoreThe aim of this study to determine the genetic distance and relationship among some Iraqi date palm cultivars by using the Random Amplified Polymorphic DNA (RAPD) technique. Molecular analysis was performed by using 10 random primers. These primers produced 176 fragment lines across 14 cultivars, Of these, 166 or 94.3% were polymorphic. The size of the amplified bands ranged between 200-2250 bp. The genetic polymorphism value of each primer was determined and ranged between 7.5-16.9%. In terms of unique banding patterns, the most characteristic banding pattern was for the Barhee cultivar with primer OP-M06 and for the Khadhrawy Mandily cultivar with primer OP-C02. Genetic distance values ranged from 0.868 to 0.125 among studied date palm
... Show MoreThe main objective of this study is to characterize the main factors which may affect the behavior of segmental prestressed concrete beams comprised of multi segments. The 3-D finite element program ABAQUS was utilized. The experimental work was conducted on twelve simply supported segmental prestressed concrete beams divided into three groups depending on the precast segments number. They all had an identical total length of 3150mm, but each had different segment numbers (9, 7, and 5 segments), in other words, different segment lengths. To simulate the genuine fire disasters, nine beams were exposed to high-temperature flame for one hour, the selected temperatures were 300°C (572°F), 500°C (932°F) and 700°C (1292°F) as recomm
... Show MoreIn this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in