Preferred Language
Articles
/
K-aZz54BmraWrQ4di2YX
Removal of Methylene Blue Dye from Synthetic Wastewater Using Iraqi Natural Plants
...Show More Authors
Abstract<p>Water contamination by industrial dyes presents significant environmental and health concerns worldwide. In this research, the efficacy of utilising polypogon monspeliensis (locally known as Skekh EsmAllah (Sh.E)) as a natural adsorbent for the elimination of Methylene Blue (MB) dye from synthetic wastewater is explored. The X-ray diffraction test elucidate that the material is a multi-phase structure. Various operational factors, comprising pH, contact time, isoelectric point, adsorbent dose, dye concentration, and temperature, are used to analyse the adsorption process systematically. The results reveal that Sh.E. has exhibited remarkable removal efficiency and adsorption capacity comparable to expensive and complex materials commonly used for dye removal. In this regard, the removal rates exceed 95% and the adsorption capacity reach 26.04 mg/g. Additionally, adsorption isotherm and kinetics studies are achieved, with the pseudo-second-order kinetic model and the Langmuir isotherm model providing the greatest fit to the experimental data. The selection of Sh.E. is based on its abundance, sustainability, and cost-free value. Nevertheless, it shows a high removal ratio, which makes it a good candidate to replace conventional materials. Overall, this research demonstrates that natural plants have the potential to replace the expensive materials.</p>
Crossref
View Publication
Publication Date
Mon Jun 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Temperature and pH on the Removal / Recovery of ZN++ from Solution by Chemical Coagulation
...Show More Authors

This work was conducted to study the treatment of industrial waste water, and more particularly those in the General Company of Electrical Industries.This waste water, has zinc ion with maximum concentration in solution of 90 ppm.
The reuse of such effluent can be made possible via appropriate treatments, such as chemical coagulation, Na2S is used as coagulant.
The parameters that influenced the waste water treatment are: temperature, pH, dose of coagulant and settling time.
It was found that the best condition for zinc removal, within the range of operation used ,were a temperature of 20C a pH value of 13 , a coagulant dose of 15 g Na2S /400ml solution and a settling time of 7 days. Under these conditions the zinc concentrat

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 04 2021
Journal Name
Geofluids
Performance Evaluation of Polyethersulfone Membranes for Competitive Removal of Cd2+, Co2+, and Pb2+ Ions from Simulated Groundwater
...Show More Authors

This paper presents studying the performance of three types of polyethersulfone (PES) membrane for the simultaneous removal of Co2+ ions, Cd2+ ions, and Pb2+ ions from binary and ternary aqueous solutions. Co2+ ions, Cd2+ ions, and Pb2+ ions with two different initial concentrations (e.g., 10 and 50 ppm) were selected as examples of heavy metals that contaminate the groundwater as a result of geological and human activities. This study investigated the effect of types of PES membrane and metal ions concentration on the separation process. For the binary aqueous solutions, the permeation flux of the PES2 membranes was higher for the separation process of solutions containing 50 ppm of Cd2+ ions and 10 ppm of Co2+ ions (24.7 L

... Show More
View Publication
Scopus (25)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reuse of Brick Waste as a Cheap-Sorbent for the Removal of Nickel Ions from Aqueous Solutions
...Show More Authors

   The potential application of granules of brick waste (GBW) as a low-cost sorbent for removal of Ni+2ions from aqueous solutions has been studied. The properties of GBW were determined through several tests such as X-Ray diffraction (XRD), Energy dispersive X-ray (EDX), Scanning electron microscopy (SEM), and BET surface area. In batch tests, the influence of several operating parameters including contact time, initial concentration, agitation speed, and the dose of GBW was investigated. The best values of these parameters that provided maximum removal efficiency of nickel (39.4%) were 1.5 hr, 50 mg/L, 250 rpm, and 1.8 g/100mL, respectively. The adsorption data obtained by batch experiments subjected to the Three i

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Carbohydrate Polymers
Synthesis, characterization of acrylamide grafted chitosan and its use in removal of copper(II) ions from water
...Show More Authors

View Publication
Scopus (108)
Crossref (98)
Scopus Clarivate Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Responsivity of porous silicon for blue visible light with high sensitivity
...Show More Authors

In this work, porous silicon (PS) are fabricated using electrochemical etching (ECE) process for p-type crystalline silicon (c-Si) wafers of (100) orientation. The structural, morphological and electrical properties of PS synthesized at etching current density of (10, 20, 30) mA/cm2 at constant etching time 10 min are studied. From X-ray diffraction (XRD) measurement, the value of FWHM is in general decreases with increasing current density for p-type porous silicon (p-PS). Atomic force microscope (AFM) showed that for p-PS the average pore diameter decreases at 20 mA. Porous silicon which formed on silicon will be a junction so I-V characteristics have been studied in the dark to calculate ideality factor (n), and saturation current (Is

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Photocatalytic Degradation of Methyl blue by TiO2 Nanoparticles Incorporated in Cement
...Show More Authors

In this study, titanium dioxide (TiO2) nanoparticles incorporated with cement were synthesis by a simple casting method as a function concentration of TiO2 (0.2, 0.4, 0.8, 1, and 2 wt%). The prepared samples were characterized using the technique of Field Emission Scanning Electron Microscope (FESEM) and UV-Visible spectrophotometer, which was used to measure the adsorption spectra. The observed photocatalytic efficiency of TiO2 nanoparticles (NP) incorporated with cement was investigated by decomposing the dye methyl blue (MB) solution under sunlight irradiation. According to the slope, the value of the k constant at the best sample is 0.8wt%, k=0.8265 min-1. FESEM image of the TiO2

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 23 2025
Journal Name
Journal Of Craniofacial Surgery
Gender Determination in Forensic Dentistry Using Bonwill’s Triangle Measurements From CBCT Scans: A Study on the Iraqi Population
...Show More Authors
Background:

The purpose of this study is to illuminate the role of CBCT in forensic dentistry through variations of mandibular measurements of Bonwill’s triangles in gender determination among the Iraqi population.

Materials and methods:

In this retrospective study 70 CBCT scans were analyzed to measure the Bonwill’s triangle, 35 for males and 35 for females aged between 20 and 50 years, all data were collected at the oral and maxillofacial radiology department in Ghazi AL-Hariri hospital for 3 months, and the data were obtained using a Kavo CBCT device (3D On De

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of The Iraqi University
Exclusion optimal portfolio from outlier by using fuzzy c-means clustering - analytical research at the Iraqi Stock Exchange
...Show More Authors

This research aims to solve the problem of selection using clustering algorithm, in this research optimal portfolio is formation using the single index model, and the real data are consisting from the stocks Iraqi Stock Exchange in the period 1/1/2007 to 31/12/2019. because the data series have missing values ,we used the two-stage missing value compensation method, the knowledge gap was inability the portfolio models to reduce The estimation error , inaccuracy of the cut-off rate and the Treynor ratio combine stocks into the portfolio that caused to decline in their performance, all these problems required employing clustering technic to data mining and regrouping it within clusters with similar characteristics to outperform the portfolio

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Some new transition metal complexes of bis (2-methyl furfuraldene)-4,4`-methylene bis (cyclohexylamine) ligand
...Show More Authors

New Fe(II),Co(II),Ni(II),Cu(II) and Zn(II) Schiff base complexes which have the molar ratio 2:1 metal to ligand of the general formula [M2( L) X4] (where L=bis(2-methyl furfuraldene)-4-4`-methylene bis(cyclo-hexylamine) ) were prepared by the reaction of the metal salts with the ligand of Schiff base derived from the condensation of 2:1 molar ratio of 2-acetyl furan and 4-4`-methylene bis (cyclohexylamine). The complexes were characterized by elemental analysis using atomic absorption spectrophotometer ,molar conductance measurements, infrared, electronic spectra,and magnetic susceptibility measurement. These studies revealed binuclear omplexes. The metal(II) ion in these complexes have four coordination sites giving the most ex

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effects of Operating Variables on Efficancy of Water Disinfection by Sodium Hypochlorite Using Al-Wathba Wastewater
...Show More Authors

The aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to

... Show More
View Publication Preview PDF
Crossref