Preferred Language
Articles
/
JxfG3JIBVTCNdQwCL8K-
Effectiveness of high-frequency vibration, cotton rolls and elastomeric wafers in alleviating debonding pain of orthodontic metal brackets: a randomized clinical trial
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Pharmaceutical Negative Results
The Effect of Ferric Citrate in Controlling Iron Deficiency Anemia and its Tolerability in a Sample of Iraqi Hemodialysis Patients: Randomized Controlled Clinical Trial
...Show More Authors

Background: The iron deficiency anemia along with hyperphosphatemia are the main complications of dialysis patients. Traditional iron supplement has been failed to correct iron deficiency anemia, therefore, the current study aimed to investigate the efficacy and tolerability of new phosphate binder, ferric citrate, in a sample of Iraqi patients with end stage renal disease on maintenance hemodialysis. Method: Prospective, randomized, open label, active controlled trial was conducted in one center for dialysis in Babylon governance. Patients were randomized to receive ferric citrate with dose of 6 g/d and calcium carbonate with dose of 3 g/d for eight weeks. Hemoglobin concentration, mean corpuscular hemoglobin concentration and count o

... Show More
Scopus Clarivate Crossref
Publication Date
Fri Mar 20 2020
Journal Name
International Journal Of Dental Hygiene
A randomized double‐blind clinical trial to evaluate the efficacy of chlorhexidine, antioxidant, and hyaluronic acid mouthwashes in the management of biofilm‐induced gingivitis
...Show More Authors
Abstract<sec><title>Objectives

To investigate the antiplaque and antigingivitis efficacy in addition to evaluating side effects and subjects’ perceptions of three commercially available mouthwashes.

Methods

This study was a double‐blind, parallel, and short‐term trial. A total of 75 dental students with biofilm‐induced gingivitis were included in the final analysis of the current study. Clinical parameters (plaque index and bleeding on probing) and the staining effect were measured at baseline and after 7 days. In addition, a VAS‐based assessment questionnaire was completed by the participants.

... Show More
View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Wed May 22 2024
Journal Name
Clinics And Practice
Efficacy of Non-Surgical Periodontal Therapy with Adjunctive Methylene Blue and Toluidine Blue O Mediated Photodynamic in Treatment of Periodontitis: A Randomized Clinical Trial
...Show More Authors

Background: This study aimed to examine the efficacy of methylene blue (MB) and toluidine blue O (TBO) photodynamic therapy (PDT) as adjuncts to root surface debridement (RSD). Methods: This split-mouth, randomized, controlled clinical trial included eighteen patients, and a total of 332 sites (control = 102, MB = 124 and TBO = 106) were examined. Two sessions of PDT were completed at baseline and two weeks after RSD. Clinical parameters of bleeding on probing (BOP), plaque index (PI), probing pocket depth (PPD), and clinical attachment level (CAL) were measured pre- and post-treatment. Results: PPD and BOP reductions in sites treated by RSD with adjunctive photosensitizers (MB and TBO) were significantly higher than in control site

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Apr 11 2024
Journal Name
Hemodialysis International
Using cryotherapy, <scp>EMLA</scp> (eutectic lidocaine/prilocaine) cream, or lidocaine spray to reduce pain during arteriovenous fistula puncture: A randomized controlled trial
...Show More Authors
Abstract<sec><title>Introduction

In hemodialysis patients, pain associated with needle insertion into an arteriovenous fistula is a physical and psychological problem. The aim of this study was to assess the effectiveness of pre‐puncture application of an ice pack, EMLA cream, or lidocaine spray to reduce pain associated with access puncture.

Methods

This was a multicenter study done in nine hemodialysis centers in Iraq. The study utilized a randomized, parallel‐group design, in which patients being dialyzed using an arteriovenous access were allocated into one of four groups. Access puncture was preceded by nothing (contr

... Show More
View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)
...Show More Authors

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of frictional forces generated by different brackets and orthodontic wires
...Show More Authors

Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-li

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
3 Biotech
Detection of orthodontically induced inflammatory root resorption-associated biomarkers from the gingival crevicular fluid by proteomics analysis: a randomized-controlled clinical trial
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Clinical Dentistry
THE EFFECT OF A PROTECTIVE BARRIER ON THE SHEAR BOND STRENGTH OF DIFFERENT ORTHODONTIC BRACKETS
...Show More Authors

Background and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b

... Show More
Scopus (2)
Scopus