Preferred Language
Articles
/
JhhOa5QBVTCNdQwCrxYV
Effect of Maternal Variables on some Physiological and Immunological Biomarkers in Iraqi Women Undergoing Caesarean Section
...Show More Authors

Pregnancy and childbirth are physiological states characterized by sudden hormonal and immunologically described changes. The current study aimed to investigate the influence of maternal variables (age, previous abortion, placental position, and fetal position) on some physiological biomarkers, such as oxytocin (OT), prolactin (PRL), cortisol, and insulin growth factor 2 (IGF -2) and some immune biomarkers such as programmed cell death protein 1 (PD-1), programmed cell death ligand 1 (PD-L1) and interleukin 6 (IL-6) in Iraqi women undergoing caesarean section (CS). Blood samples were collected from 48 pregnant women in the age range (16-43 years) and serum was obtained to determine the levels of the above biomarkers. The effect of maternal age on physiological biomarkers showed that OT levels increased significantly with maternal age (P≤0.001), whereas PRL, cortisol, and IGF-2 levels were not (P˃0.05), showing differences between age categories. The effect of maternal age on immune biomarkers showed that PD-1 levels decreased significantly (P<0.05) and PD-L1 and PD-1/PD-L1 levels were highly significant (P≤ 0.001), however, IL-6 level shows a non-significant (P˃0.05) difference between age categories. Regarding the effect of previous abortion, statistical analysis showed that cortisol levels were significantly (P<0.05) lower in women with previous abortion compared to women without previous abortion, while OT, PRL, and IGF-2 levels were not significantly different (P ˃ 0.05) difference between the two groups. PD-1 and PD-L1 levels showed a significant (P<0.05) decrease in women with previous abortion compared with women without abortion, while IL-6 mirror images did not differ significantly (P˃0.05) between the two groups. The effect of placenta position showed that when the placenta was in the anterior position, the PRL level was significantly increased (P≤0.001), IGF-2 level was significantly decreased (P<0.05), while the OT and cortisol levels were significantly higher (P≤0.001) compared with the posterior position There was no significant difference between the two groups (P˃0.05). When the placenta was located in the anterior compared with the posterior, the level of PD-L1 was significantly (P<0.05) lower, while the levels of PD-1 and PD -1/PD- were not significantly different (P˃0.05). L1 and IL-6 between the two groups. According to fetal position, statistical analysis showed no significant difference in all physiological and immune biomarkers when the fetus was in cephalic or breech position (P˃0.05). It can be concluded that the more maternal variables which affect on the physiological and immunological biomarkers of the women undergoing caesarean section are maternal age and a previous abortion.

Crossref
View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Effect of annealing temperature on the optical properties of (Cu2S)100-x( SnS2 )x thin films
...Show More Authors

Thin films of (Cu2S)100-x( SnS2 )x at X=[ 30,40, &50)]% with thickness (0.9±0.03)µm , had been prepared by chemical spray pyrolysis method on glass substrates at 573 K. These films were then annealed under low pressure of(10-2) mbar ,373)423&473)K for one hour . This research includes , studying the the optical properties of (Cu2S)100-x-(SnS2)x at X=[ 30,40, &50)]% .Moreover studying the effect of annealing on their optical properties , in order to fabricate films with high stability and transmittance that can be used in solar cells. The transmittance and absorbance spectra had been recorded in the wavelength range (310 - 1100) nm in order to study the optical properties . It was found that these films had direct optical band

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative

... Show More
View Publication Preview PDF
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Journal Misalignment on the Static Characteristics of Porous Journal Bearings Lubricated with Couple Stress Fluid
...Show More Authors

In this paper, a theoretical study to the effect of journal misalignment on the static characteristics of oil filled porous journal bearing when lubricated with couple stress fluid has been carried out.

The analytical model used through this work is for a bearing with isotropic permeability. Considering isotropic permeability the Reynolds' equation for the oil film is modified to include a so – called filter term and the effect of fluid coupled stress. The pressure equation for the porous medium is obtained from Darcy's law and continuity equation. The equation which was used to evaluate the oil film thickness was modified to include the effect of possible misalignment in longitudinal and transverse directions. The governing eq

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
The effect of the activation functions on the classification accuracy of satellite image by artificial neural network
...Show More Authors

View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
The Effect of Diyala River Water Quality on the Quality of Tigris River Water using GIS Mapping
...Show More Authors

The assessment of a river water’ quality is an essential procedure of monitor programs and is used to collect basic environmental data. The management of integrated water resources in a sustainable method is also necessary to allow future generations to meet their water needs. The main objective of this research is to assess the effect of the Diyala River on Tigris River water quality using Geographic Information System (GIS) technique. Water samples have been collected monthly from November 2017 to April 2018 from four selected locations in Tigris and Diyala Rivers using the grab sampling method. Fourteen parameters were studied which are Turbidity, pH, Dissolved Oxygen, Biological Oxygen Demand, Electrical Conductivi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Effect of Polyurethane Resin Additives on the Impact Toughness of Epoxy Resin Reinforced with woven roving Glass
...Show More Authors

I mpact strength for Epoxy/Polyurethane, Blends and their composites with two
layers of Glass fibers (0-90) are calculated.
The impact strength of the blends and composites decrease with increasing weight
by weisht percentage of polyurethane . This result is attributed to the high elasticity
of PU , and to the immiscibility between the polymer blends as well as the fiber
delaminates

View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Urban Form on Temperature for Hot Arid Zones. The Case Study of Baghdad, Iraq
...Show More Authors

The research aims to determine optimal urban planning and design indicators of the urban clusters form in hot arid zones through studying of three urban areas in Baghdad, analyzing their urban indicators which include floor area ratio (FAR), urban clusters height, building density or land coverage, green areas, paved areas, shading ratio and how they affect urban temperature. The research reached the conclusion that air outdoor temperature on urban areas affected primarily by shadows casted on the ground, the effect of shaded area equals (5) times the effect of paved areas and (3.7) times the effect of green areas, this means that increasing urban clusters height in hot arid zones could minimize air outdoor temperature, building

... Show More
View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The effect of story- grammar instruction on poor college student s 'achievement of narrative texst theme identification
...Show More Authors

0

View Publication Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Numerical Investigation of the Effect of Inserted Twisted Tape inside Submerged Bundle Tubes on its Thermal Performance
...Show More Authors

Twisted tape insertion in smooth plain tube is one of types of passive methods that is used to enhance heat transfer. Swirl fluid flow inside tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with twisted tape has twist ratio of y = (H/D) = (150/17) =8.8 along with a plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nusselt number

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Effect of Elevated Temperature on the Compressive Strength of Reactive Powder Concrete (RPC) Containing Polyvinyl Chloride (PVC)
...Show More Authors

Fire is the most sever environmental condition affecting on concrete structures, thus investigating for fire safet, IJSR, Call for Papers, Online Journal

View Publication