Mobile ad hoc network is nothing but the temporary network which is having the collection of mobile nodes. Routing and broadcasting are major operations of MANET network. The major operation in ad hoc mobile network is the broadcasting which sometime results to storm problem of the broadcast if the forwarding mechanism is not properly designated. Thus the challenges in the MANET are to reduce the broadcasting redundancy and under high transmission error rate provides high delivery ratio. Hence in our proposed research, we are introducing and investigating the new mechanism of broadcasting called Dual Covered Broadcast. This method takes the broadcast redundancy advantage order to improve packet delivery ratio especially under environments where transmission error rate higher. According to proposed approach, among the senders 1-hop neighbors, forwarding nodes which are selected are only retransmit the broadcasting message. There are two ways for selection of forwarding nodes and either of one is used depending on the network conditions. The source node provides forwarding node retransmission as acknowledgement of reception of packet. If the source node not getting the retransmissions of its forwarding nodes, source node resend the packets until the maximum threshold will reach. For the simulation of this project we used the Microsoft .Net framework and our simulation results shows that proposed method performing well under the high transmission error rate. From the simulated results we claim that investigated approach for the broadcasting is more efficient as compared to the existing approaches.
This paper presents an experimental and theoretical analysis to investigate the two-phase flow boiling heat transfer coefficient and pressure drop of the refrigerant R-134a in the evaporator test section of the refrigeration system under different operating conditions. The test conditions considered are, for heat flux (13.7-36.6) kW/m2, mass flux (52-105) kg/m2.s, vapor quality (0.2-1) and saturation temperature (-15 to -3.7) ˚C. Experiments were carried out using a test rig for a 310W capacity refrigeration system, which is designed and constructed in the current work. Investigating of the experimental results has revealed that, the enhancement in local heat trans
... Show MoreSeveral parameters affect the properties of Portland cement and one of these parameters is the cooling rate of the clinker. If the effectiveness of the cooling method of the clinker increases, a good enhancement in the properties of Portland cement will be found. Depending on the new cooling method suggestion by Nasr et. al. [20], the counter pattern of air clinker flow was studied using (FLUENT 6.3.26). The dimensions of the cooling room in grate cooler, the constant mass flow rate of both clinker and air, different height ratios, and different clinker porosity were considered in this numerical work. The results show that the heat transfers in the first half of the cooling room (0 < X < 0.9 m) is larger than that in the secon
... Show MoreTwo‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
Heat transfer performance of two horizontal parallel plates subjected to discrete heating from the upper plate is studied and analyzed under the condition of different gap size between the heating elements with water as the working fluid. The investigation includes the variation of Reynolds number and the heat flux along with the position of the heating elements to discover the effect of different boundary conditions on the gap size variation. Results show that gap size between the heating elements has a crucial impact on the heat transfer process inside the channel, when the gap size increased a remarkable enhancement is achieved. This result is also confirmed with the investigated range of Reynolds number and the heating value. Results al
... Show MoreAfter Hamdallah and his success on the realization of this manuscript (a letter in detail what was said in the parents of the Prophet Ibn Kamal Pasha (d. 940 e) study and investigation I will review some of the results reached in the realization of this manuscript:
1. The hadiths mentioned in this manuscript are mostly placed or weak.
2 - We are not entitled to speak about the silence of the law for saying Almighty ﭽ ﮮ ﮯ ﮰ ﮱ ﯓ ﯔ ﯕ ﯖ ﯗ ﯘ ﯙ ﭼ Table: 101.
3 in which harm to our Holy Prophet وله تع ﮂ ﮃ ﮄ ﮅ ﮆ ﮈ ﮉ ﮊ ﮋ ﮌ ﮍ ﮎ ﭼ parties: 57.
4 Because the parents of the Prophet of the people of the period ordered them to God for the Almighty ﭽ ﯨ ﯩ ﯪ ﯫ ﯬ
It has been shown in ionospheric research that calculation of the total electron content (TEC) is an important factor in global navigation system. In this study, TEC calculation was performed over Baghdad city, Iraq, using a combination of two numerical methods called composite Simpson and composite Trapezoidal methods. TEC was calculated using the line integral of the electron density derived from the International reference ionosphere IRI2012 and NeQuick2 models from 70 to 2000 km above the earth surface. The hour of the day and the day number of the year, R12, were chosen as inputs for the calculation techniques to take into account latitudinal, diurnal and seasonal variation of TEC. The results of latitudinal variation of TE
... Show MorePore volume, pore diameter, and pore volume distribution of three of Iraqi natural clay deposites were measured using mercury intrusion porosimetry .The clays are white kaolin, colored kaolin, and bentonite .The results showed that the variation of the pore area of the clay deposites followed the following order :- Coloured Kaolin > White Kaolin > Bentonite While the pore volume may be arranged as in the following sequence:- White Kaolin > Coloured Kaolin >Bentonite Also , Bentonite exhibits the narrow range pore size distribution than the white and coloured kaolin.