This research included the study of different factors that may effect on gatifloxacin stability (anew quinolone synthetic antibacterial agent) in its aqueous solution in order to develop and optimize the best delivary of the drug to the eye (as eye drop) with maximum local concentration and minimum systemic absorption and toxicity.Different formulas of gatifloxacin solution for ophthalmic use (0.3%)w/v were prepared in citrate, acetate,citrate/phosphate and phosphate buffers,their tonicity adjusted with suitable quantity of sodium chloride.The effect of different factors that might affectthe stability of gatifloxacin in its prepared ophthalmic solution was studied and determined spectrophotometrically at 287 nm. The results showed that The use of disodium edetate as asequestering agent gave more stable formula and gatifloxacin undergoes hydrolysis at low pH with optimum stability at pH 6.0, which is the most suitable pH for this ophthalmic solution. The type of buffer significantlyaffects on the rate of hydrolysis of gatifloxacinspecially at low pH and optimum stability was obtained by using phosphate buffer. The concentration of phosphate buffer had a significant effect on the hydrolysis of gatifloxacin and the rate of hydrolysis increased as the concentration buffer increased. Ionic strength affects the hydrolysis rate of gatifloxacin and the hydrolysis increased as the ionic strength increased. Light had a significant effect on the rate of hydrolysis of the drug and the drug losses 10% of its potency after 10 monthes of light exposure at room temperature. The prepared formula J ( gatifloxacin 0.3% in 0.1M phosphate buffer with sodium chloride 0.26% , xanthan gum 0.2% and disodium edetate 0.01%) is thebest stable one and had no irritation on the eye of experimental animals, and it passes successfully quality control tests including: drug content, pH, clarity and sterility test and comply with united state pharmacopoeia for ophthalmic solutions.
In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
The present study included the use of the approximate semi-experimental method, the time-independent density function theory (unrestricted), the time-dependent density function theory, and Hartree-Fock method to calculate the reaction pathway of the anti-inflammatory drug diclofenac with its common ionic carriers (sodium and potassium). The basis sets used were STO-3G, 3-21G, 6-31G, and 6-311G. The drug was studied with two new proposed carrier ions (lithium and calcium) which were compared with common carriers. The calculations included the optimized geometrical structure and some physical properties such as standard heat of formation, dipole moment, total energies, and analytical spectra of IR, UV-VIS and 1H NMR. The biologi
... Show MoreAn expression for the transition charge density is investigated where the deformation in nuclear collective modes is taken into consideration besides the shell model transition density. The inelastic longitudinal form factors C2 calculated using this transition charge density with excitation of the levels for Cr54,52,50 nuclei. In this work, the core polarization transition density is evaluated by adopting the shape of Tassie model together with the derived form of the ground state two-body charge density distributions (2BCDD's). It is noticed that the core polarization effects which represent the collective modes are essential in obtaining a remarkable agreement between the calculated inelastic longitudinal F(q)'s and those of experimen
... Show MoreThere is a set of economic factors that affect the rationalization of decisions on unexploited resources within the economic unit and here determines the problem of the search for the question of what economic factors cause the emergence of asymmetric costs, and aims to identify these factors in the costs of adjustment to resources, change in The size of the activity of the economic unit, the general trend of sales change in the previous period, and the economic level of the country. Rh measure the impact of these factors on economic unity, and taking into consideration the impact when formulating decisions.
The aim of this study is to assess the influence of some risks factors on the fistula development after palatoplasty to improve the outcome of the patients
A total of 48 patients (the males were 22, The females were 26) were included in this study. All the patients were examined weekly for the first month postoperatively to assess any breakdown in the wound by inspection and by asking the parents for any nasal regurgitation during fluids feeding.
Background: Autism is a complex developmental disability that typically appears during the first three years of life. Autism affects the normal development of the brain in the areas of social interaction and communication skills.Objectives: To identify risk factors for Autism among a sample of autistic children in Baghdad city. Type of the study: this is a case – control, study. Methods: This study was conducted during the period of data collection extended from first of November 2010 until the first of April 2011,The total number of children involved was 100children with diagnosis of autism. Handred children who are free from autism were taken as the control sample. Results: there was a significant association between paternal age and
... Show MoreBackground: Birth trauma is defined as injury to neonates resulting from mechanical forces (such as compression or traction) during the process of birth. Birth injury is used to denote avoidable and unavoidable mechanical and hypoxic- ischemic injury incurred by neonates during labor and delivery. Maternal, labor and infant factors can predispose to birth traumas. Many types of birth traumas can be found including intra and extra cranial, spinal, peripheral nerves, fractures and visceral.
Patients and methods: A cross sectional study was done on 200 babies (100 babies for the study group and 100 babies for the control group), admitted to special care baby unit of Baghdad Teaching Hospital, during the peri
Background: Infertility is a relatively common condition. It can be attributed to factors in a female partner, a male partner, or in both partners. However, certain socio-demographic and life style factors have been linked to female infertility.
Objective: To determine the association between female infertility and selected risk factors.
|
Patients and Methods: This is a case
... Show MoreThis study aimed to improve the microencapsulation technique using a type coating the encapsulation Layer by Layer, which provide the best protection for life Lactobacillus casei in the extrusion method and use the microencapsulation of materials of the protein concentrated by protein 80% and the coating with alginate and chitosan have the results showed the variation in the difference of the binding process encapsulation yield among the types of coating through. by studying of these the effect o stability of the bio probiotic free cell and the three types coated towards three different concentrations from bile salts 0, 0.3, 0.5 and 0.7% when the periods of time different of zero and two and three hours at incubation the recorded
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show More