This study aimed to evaluate the reservoir petrophysical properties (porosity, water saturation, and permeability) for optimal flow unit assessment within the Sadi Formation. Utilizing open hole logging data from five wells, the Sadi formation was divided into two rock units. The upper unit (A) is 45-50 meters thick, mainly consisting of limestone, mainly consisting of shaly limestone at the lower part. The lower unit (B) has a thickness of approximately 75-80 meters and is primarily composed of limestone, further subdivided into three subunits (B1, B2, B3). The average water resistivity is 0.04 ohm-m, and the average mud filtrate resistivity is 0.06 ohm-m. The Pickett plot was utilized to determine Archie parameters (tortuosity factor=1, cementation factor= 2, saturation exponent = 1.94). Petrophysical properties were determined through a sequence of operations involving lithology identification, shale volume estimation, porosity calculation, water saturation calculation, and permeability estimation. Lithology was identified using neutron, density and sonic logs with (N-D, M-N) cross plots, which show that the Sadi Formation is mainly limestone. The Gamma ray log was employed to estimate the shale volume of the Sadi Formation using the Larionov equation of old rock, resulting in a shale volume of 7%-58%. After calculating porosity using neutron-density logs, the resulting porosity matched the core porosity. Archie equation was used to calculate the formation’s water saturation, with water saturation less than 0.48 (cut-off) obtained in B1, B2 and B3 units. Finally, the formation permeability was estimated using the Flow Zone Indicator method, which provided a good match with core permeability. Porosity and water saturation were estimated with depth using Techlog software. The best hydrocarbon-holding unit is B2, which has the highest porosity, lowest water saturation, and the best permeability, with a thickness of 20.1 meters. As a result of this study, core plug analysis and well logging data identified eight distinct units in the Sadi Formation. There are three flow sub-units in upper Sadi (B1), three flow sub-units in Sadi (B2) and two sub-units in Sadi (B3). Additionally, it has been found that the marl rock unit (A2) separates the water-bearing zone (A1) from the oil-bearing zone (B).
Physically based modeling approach has been widely developed in recent years for the simulation of dam failure process due to the lack of field data. This paper provides and describes a physically-based model depending on dimensional analysis and hydraulic simulation methods for estimating the maximum water level and the wave propagation time from breaching of field test dams. The field physical model has been constructed in Dabbah city to represent the collapse of the Roseires dam in Sudan. Five cases of a dam failure were studied to simulate water flood conditions by changing initial water height in the reservoir (0.8, 1.0, 1.2, 1.4 and 1.5 m respectively).The physical model working under five cases, case 5 had the greatest influence of t
... Show MoreThe Innovation Of Knowledge Is An Important And A Key Element In The Progress And Business Excellence Organizations, Therefore Requires Several Elements To Help Create And Implement And Move The Innovation Process Of Knowledge, Including The Strategic Empowerment Associated With The Element Of The Process Of Strategic Momentum Engine Driven Wheel Continuous Dynamic Innovation, And Focused Research Problem By Measuring The Availability Of Strategic Empowerment When Individuals From By Senior Departments And Ways To Help Organizations To Provide Empowerment Commensurate With The Requirements Of Achieving The Goals Of Time And Place Appropriate For The Individual, And The Importance Of Research Stems From The Importance Of The Varia
... Show MoreOne of the principle concepts to understand any hydrocarbon field is the heterogeneity scale; This becomes particularly challenging in supergiant oil fields with medium to low lateral connectivity and carbonate reservoir rocks.
The main objectives of this study is to quantify the value of the heterogeneity for any well in question, and propagate it to the full reservoir. This is a quite useful specifically prior to conducting detailed water flooding or full field development studies and work, in order to be prepared for a proper design and exploitation requirements that fit with the level of heterogeneity of this formation.
in this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.
The present study aimed at identifying the role of supervisory and training practices in the field education program in achieving course objectives from the perspective of the student teachers in the Faculty of Science and Arts in sharourah, and its relationship to some variables (gender, specialization,estimation). To achieve this, the researcher used the descriptive-analytical method, and the study tool was designed, which consists of (24) items distributed on two axes: the objectives of field education and supervisory and training practices.Then, the study tool was applied to the research sample represented in the entire study community, which consists of (65) male and female students in the Faculty of Sciences and Arts in
... Show MoreAn investigation was conducted for the improvement of viscosity index of light lubricating oil fraction (40 stock)
obtained from vacuum distillation unit of lube oil plant of Daura Refinery, using solvent extraction process.
In this study furfural solvent was used to extract the undesirable materials which reduce the viscosity index of raw
lubricating oil fraction.
The studied effecting variables of extraction were extraction temperature range from 70 to 110°C, and solvent to oil
ratio range from 1:1 to 4:1 (wt/wt).
The n-d-M method was used for calculation of carbon distribution and structural group analysis of the raffinate
produced from furfural extraction.
Also the three component phase diagram for a mixed-ba
The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show MoreBackground: Insulin resistance is associated with metabolic syndrome , type 2 diabetes and representing a risk factor for cardiovascular disease . This relationship may be modulated to some extent by age related changes in sex hormone status.. In particular, reduced total testosterone (TT) levels have been associated with insulin resistance and subsequent risk for developing type 2 diabetes. Aim of study: we examined whether low total testosterone level were associated with insulin resistance in young adult men. Methods: a total of 83 men (young adult men) divided into 2 group : (group1 ) 49 men with a risk factor for insu
... Show MoreWe found that 4,5- diphenyl- 3(2- propynyl) thio- 1??-triazole [1? forms a complex with Pd (11) ion of ratio 1:1 which absorbs light in CH2CI2 at 400 nm, and 4,5- diphenyl- 3(2- propenyl) thio- 1,2,4- triazole [II] forms complexes with Pd (II) ion of ratio 1:1 which absorbs light at 390 nm, and of ratio 2:1 which absorbs light at 435 nm. On the other hand, we found that the new derivative 4- phenyl- 5( p- amino phenyl) -3- mercapto- 1,2,4- triazole ?111? forms complexes with Cu (II) ion of the ratio 1:1 which absorbs light at 380 nm, with Ni (II) ion of the ratio 3:1 which absorbs light at 358 nm; and with Co (11) ion of the ratio 3.2:1 which absorbs light at 588 nm. The ratio of the complexes were determined by measuring the electronic spe
... Show More