Aim: The present study aims to improve the poor water solubility of zaltoprofen which is a non-steroidal anti-inflammatory drug (NSAIDs) with a potent analgesic effect using solid dispersion then formulate it as a hollow type suppository to be more convenient for geriatric patients. Materials and Method: Zaltoprofen solid dispersions were prepared by solvent evaporation technique in different zaltoprofen: Soluplus® ratios. Results: Among the formulations tested, zaltoprofen solid dispersion preparation using 1:5 (zaltoprofen: Soluplus®) ratio showed the highest solubility and selected for further investigation. Solid dispersion characterization was evaluated by differential scanning calorimetry (DSC), X-ray diffraction study (XRD) and Fourier transformation infrared spectroscopy (FTIR). DSC and XRD analysis showed a complete transformation of zaltoprofen in the solid dispersion from a crystalline state to amorphous state. The selected zaltoprofen solid dispersion was further incorporated into hollow type suppositories using witepsol H 35 as a suppositories base. The hollow type suppositories were evaluated for hardness test (breaking strength), melting time, softening time and in vitro drug dissolution rate. Formula F8 containing zaltoprofen solid dispersion in the whole of hollow type suppository showed the shortest and significantly the highest dissolution rate profile (100% within 15 min) compared to other hollow type suppository formulas prepared that contain zaltoprofen powder in its whole. Conclusion: It is concluded that the development of zaltoprofen solid dispersions using Soluplus® as hollow-type suppositories could be used as a promising approach for improving the solubility of poorly water-soluble drugs
One of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system wit
... Show MoreThe main aim of this paper are the design and implementation of a pharmaceutical inventory database management system. The system was implemented by creating a database containing information about the stored medicines in the inventory, customers making transactions with the pharmaceutical trading company (which owns the inventory), medical suppliers, employees, payments, etc. The database was connected to the main application using C sharp. The proposed system should help in manag inginventory operations which include adding/updating employees’ information, preparing sale and purchase invoices, generating reports, adding/updating customers and suppliers, tracking customer payments and checking expired medicines in order to be disposed
... Show MoreBackground: Acute appendicitis is the most common surgical abdominal emergency with a life time prevalence of 1 to 7 individuals. Because the clinical diagnosis of acute appendicitis remains a challenge to surgeons, so different aids were introduced like different scoring systems, computer aided programs, ultrasonography, computerized tomography, Magnetic resonance imaging, Gastrointestinal tract contrast studies and laparoscopy to improve the diagnostic accuracy.
Objective: To evaluate ultrasound in the diagnosis of acute appendicitis in those patients clinically diagnosed with histopathology as gold standard.
Methods: A cross sectional study carried in Al-kindy Teaching
... Show MoreThe levels of circulating angiogenic and anti-angiogenic factors, namely vascular endothelial growth factor–A (VEGF-A) and soluble vascular endothelial growth factor receptor-1 (sVEGFR-1), have been linked to the development of renal dysfunction due to the proliferation of microvasculature within the kidneys of type 2 diabetic (T2DM) patients. The study aims to scrutinize serum levels of VEGF and sVEGFR-1 in a sample of Iraqi diabetic nephropathy patients to support their reliability as markers for the prediction of nephropathy in type 2 diabetes mellitus patients as well as to assess the ACE inhibitor’s effect on the levels of these two markers. Method: The ninety participants of this case-control study were split into three gr
... Show MoreBackground: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t
... Show MoreBack ground: During acrylic resin processing, the mold must be separated from the surface of the gypsum to prevent liquid resin from penetrating into the gypsum, and water from the gypsum seeping into the acrylic resin. For many years, tin foil was the most acceptable separating medium, and because it's difficult to apply, a tin-foil substitute is used. In this study, olive oil is used as an alternative to tin foil separating medium for first time, so the aim of the study was to evaluate its effect as a separating medium on some physical properties such as (surface roughness, water sorption and solubility) of acrylic resins denture base comparing it with those processed using tin-foil and tin foil substitute such as (cold mold seal) separat
... Show MoreThis work examines numerically the effects of particle size, particle thermal conductivity and inlet velocity of forced convection heat transfer in uniformly heated packed duct. Four packing material (Aluminum, Alumina, Glass and Nylon) with range of thermal conductivity (from200 W/m.K for Aluminum to 0.23 W/m.K for Nylon), four particle diameters (1, 3, 5 and 7 cm), inlet velocity ( 0.07, 0.19 and 0.32 m/s) and constant heat flux ( 1000, 2000 and 3000 W/ m 2) were investigated. Results showed that heat transfer (average Nusselt number Nuav) increased with increasing packing conductivity; inlet velocity and heat flux, but decreased with increasing particle size.Also, Aluminum average Nusselt number is about (0.85,2.
... Show MoreCocrystallization is an emerging approach for improving physico-chemical characteristics of an active pharmaceutical ingredient (API) for instance dissolution rate, solubility, stability in addition to mechanical properties without affecting their therapeutic activity. It is of great importance when other approaches like salt or polymorph formation do not encounter the estimated targets. In this review article, an outline of pharmaceutical cocrystals will be presented, with highlighting on factors affecting cocrystallization which include ∆pKa, donors and acceptors hydrogen bonds, molecular recognition point, synthon forming functional groups flexibility, dicarboxylic acid coformers carbon chain length and solvent effe
... Show MoreNew bidentate dithiocarbamate ligand (NaL) namely [Sodium-2-(((3-methyl -4- “(2,2,2-tri fluoro ethoxy) pyridin-2”-yl) methyl) sulfinyl)-1H-benzoimidazole -1-carbodithioate] was prepared. This free ligand was synthesized from the reaction of a (RS)-2-([3-methyl -4-(2,2,2-tri fluoroethoxy) pyridin-2-yl] methyl sulfinyl)-1H benzoimidazole, CS2 and NaOH in methanol as solvent. From reaction of dithiocarbamate salt (NaL) with metal ions (M); Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pd(II)”, have obtained the DTC complexes at general molecular formula [M(L)2(H2O)2] and [Pd(L)2]. To characterize the ligand and its complexes, used different analyses methods such FTIR, UV-Vis, elemental microanalysis, atomic absoreption, magnetic susceptibil
... Show More