Preferred Language
Articles
/
JRd-P48BVTCNdQwC4mbL
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration in the range of 2.0-10 µmol/L with a limit of detection 0.35 µmol/L, 0.9981 (R2), and 2.0-12 µmol/L with a limit of detection 0.4 µmol/L and 0.9973 (R2) for measuring cells 1 and 2, respectively. The intra-day precision for three serial estimations of 5.0 and 9.0 µmol/L of MBH exhibited an RSD % of 0.23 % and 0.77 % and 0.68 % and 0.13 %, for cell 1 & 2, respectively. While the inter-day precision for three serials of three days exhibited an RSD % of 0.03 % and 0.77 % and 0.11 % and 0.07 %, for measuring cells 1 & 2, respectively. The accuracy of the developed method has expressed as an error % (E%) and a Rec % (recovery percentage), which was between 100.35 to 101.15 and 99.70 to 101.56 for cell 1 and cell 2, respectively. The present flow injection method has shown no interference effect from the common excipients and permits quantitively determination of 60 samples per hour. The developed method was successfully applied for the quantitative determination of MBH in different tablets containing 135 mg with excellent recovery percentage.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri May 23 2025
Journal Name
Reproductive Health Of Woman
Molecular detection of Rubella virus (1E genotype) in clinical sample of pregnant women, and it’s related to abortion
...Show More Authors

Pregnant women who have rubella may potentially pass the infection on to their unborn offspring. A congenital rubella infection can result in a miscarriage, stillbirth, and congenital rubella syndrome. The only member of the Togaviridae family’s Rubivirus genus, the Rubella virus (RV) is a positive-polarity, single-stranded RNA virus genome surrounded by a lipoprotein envelope with spike-like, hemagglutinin-containing surface projections.The objective: to determine the Rubella virus (1E genotype) in pregnant woman and its relation to spontaneous miscarriage.Materials and methods. A total of 174 women which visited Al-Elweya Teaching Hospital, Baghdad, Iraq, were screened according to the following criteria: women with a history of

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Water flow velocity and oxide film formation effect on copper pipe corrosion
...Show More Authors

An overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .

View Publication Preview PDF
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Three Weighted Residuals Methods for Solving the Nonlinear Thin Film Flow Problem
...Show More Authors
Abstract<p>In this paper, the methods of weighted residuals: Collocation Method (CM), Least Squares Method (LSM) and Galerkin Method (GM) are used to solve the thin film flow (TFF) equation. The weighted residual methods were implemented to get an approximate solution to the TFF equation. The accuracy of the obtained results is checked by calculating the maximum error remainder functions (MER). Moreover, the outcomes were examined in comparison with the 4<sup>th</sup>-order Runge-Kutta method (RK4) and good agreements have been achieved. All the evaluations have been successfully implemented by using the computer system Mathematica®10.</p>
View Publication
Crossref (1)
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Chaos, Solitons &amp; Fractals
A semi-analytical iterative method for solving nonlinear thin film flow problems
...Show More Authors

View Publication
Crossref (20)
Crossref
Publication Date
Wed Jun 16 2021
Journal Name
Biochemical And Cellular Archives
Synthesis, characterization and pharmaceutical studies of schiff base from 2-pyrrolidinone derivative and imidazole-2-carboxaldehyde and corresponding complexes with Metal (||)
...Show More Authors

Synthesis, characterization and pharmaceutical studies of schiff base from 2-pyrrolidinone derivative and imidazole-2-carboxaldehyde and corresponding complexes with Metal (||)

Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Global Pharma Technology
Spectrophotometric determination of loratadine in syrup and study viscosity conductivity and thermodynamic of binary mixed systems of surfactants with loratadine"
...Show More Authors

Scopus
Publication Date
Sun Jan 01 2017
Journal Name
Iraqi Journal Of Medical Sciences
ISOLATION, IDENTIFICATION AND DETERMINATION OF ANTIFUNGAL SENSITIVITY OF FUNGI ISOLATED FROM A SAMPLE OF PATIENTS WITH RHINOSINUSITIS IN BAGHDAD CITY
...Show More Authors

View Publication
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Method Combined with HPLC for Bisphenol F Determination in Plastic Bottled Water and Thermal Paper
...Show More Authors

Based on the diazotization-coupling reaction, a new, simple, and sensitive spectrophotometric method for determining of a trace amount of (BPF) is presented in this paper. Diazotized metoclopramide reagent react with bisphenol F produces an orange azo-compound with a maximum absorbance at 461 nm in alkaline solution. The experimental parameters were optimized such as type of alkaline medium, concentration of NaOH, diazotized metoclopramide amount, order additions, reaction time, temperature, and effect of organic solvents to achieve the optimal performance for the proposed method. The absorbance increased linearly with increasing bisphenol F concentration in the range of 0.5-10 μg mL-1 under ideal conditions, with a correlati

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Detection of Aflatoxin B1 among Early and Middle Childhood Iraqi Patients
...Show More Authors

      The study was conducted for the detection of Aflatoxin B1(AFB1) in the serum and urine of 42 early and middle childhood patients (26 male and  16 female ) with renal function disease, liver function disease, in additional to atrophy in the growth and other symptoms depending on the information within consent obtained from each patient, in addition to 8 children, apparently healthy, as  the control. The technique of HPLC was used for the detection of AFB1 from all samples. The results showed that out of 42 patient children, 19 (45.2%) gave positive detection of AFB1 in the serum among all age groups patients with a mean of 0.88 ng/ml and a range of (0.12-3.04) ng/ml. This was compared with the cont

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF