Preferred Language
Articles
/
JRY3s4sBVTCNdQwC69eU
A correlation between body mass index and refractive errors
...Show More Authors

Background. Body mass index (BMI) is a person's weight in kilograms (or pounds) divided by the square of height in meters (or feet). Obesity affects a wide spectrum of age groups, from the young to the elderly, and there are several eye diseases related to obesity like diabetic retinopathy, floppy eyelid syndrome, retinal vein occlusion, stroke-related vision loss, age-related macular degeneration, and possibly, refractive errors. Refractive errors (RE) are optical imperfections related to the focusing ability of the eye and are the main cause of visual impairment which may result in missed education and employment opportunities, lower productivity and impaired quality of life. Aim. The study aimed to find an association between body mass index (BMI) and refractive errors. Methodology. A cross-sectional study was designed to involve a representative sample of medical students in Al-Kindy College of medicine, from December 8, 2021 to January 10, 2022. Weight and height were measured. BMI was estimated, and their refractive error was assessed. Results. A total of 400 students participated in the study, of which 191 (47.8%) had refractive errors, whereas 209 (52.2%) were emmetropic. Thirty-seven point eight percent of the participants had BMI > 25. A significant relationship between refractive errors and all BMI groups was found (p < 0.025). Compared to normal weight group, overweight and obese groups, only the underweight group showed a significant relationship with refractive errors, p < 0.006. Conclusion. Myopia is associated with being underweight, hence the link between the two is statistically significant. The severity of this condition, however, is unaffected by body mass index. Myopia was not a concern among students with normal or high body mass index (BMI).

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Apr 05 2024
Journal Name
International Journal Of Science And Research (ijsr)
Effect of Body Mass Index on Eruption Time of Permanent First Molars and Incisors among a Group of 6- 8 Year Old Iraqi School Children
...Show More Authors

View Publication
Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Commun.fac.sci.univ.ank.series A2-a3
ULTRAHIGH SENSITIVE REFRACTIVE INDEX SENSOR BASED ON TAPERED MULTICORE OPTICAL FIBER
...Show More Authors

The refractive index sensors based on tapered optical fiber are attractive for many industries due to sensing capability in a variety of application. In this paper, we proposed a refractive index sensor based on multicore fiber (MCF) sandwiched between two standard single mode fibers (SMF). The sensor consisting of three sections, SMF- MCF-SMF is structurally simple and can be easily produced by joining these parts. The MFC contains seven cores and these cores are surrounded by a single cladding. The sensing region is obtained by tapering the MCF section where the evanescent field is generated. The single mode propagating along the SMF is stimulated at the first joint and is coupled to the cladding modes. These modes interfere with the core

... Show More
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 02 2023
Journal Name
East European Journal Of Physics
Evaluation of the Influence of Body Mass Index and Signal-to-Noise Ratio on the PET/CT Image Quality in Iraqi Patients with Liver Cancer
...Show More Authors

Image quality has been estimated and predicted using the signal to noise ratio (SNR). The purpose of this study is to investigate the relationships between body mass index (BMI) and SNR measurements in PET imaging using patient studies with liver cancer. Three groups of 59 patients (24 males and 35 females) were divided according to BMI. After intravenous injection of 0.1 mCi of 18F-FDG per kilogram of body weight, PET emission scans were acquired for (1, 1.5, and 3) min/bed position according to the weight of patient. Because liver is an organ of homogenous metabolism, five region of interest (ROI) were made at the same location, five successive slices of the PET/CT scans to determine the mean uptake (signal) values and its standard deviat

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 04 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Evaluation of the Relationship between Osteoporosis and Body Fat Mass of the Upper and Lower Extremities by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Using dual-energy X-ray absorptiometry, body fat mass has been determined. The assessment of body fat mass was conducted utilizing dual-energy X-ray absorptiometry analysis of the pelvis and vertebral column. While it is acknowledged that osteoporosis can impact both body fat mass and bone mineral density, the particulars of this relationship currently remain uncertain. Objective: The aim of the present investigation is to assess gender differences in the effects of osteoporosis on the body fat mass of the upper and lower extremities. Method: 170 individuals participated (85 males and 85 females) in this study. Patients who presented with bone discomfort consisted of 40 males and 40 females. In addition, 90 apparently he

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Optical Fiber Technology
Highly sensitive measurement of surrounding refractive index using tapered trench–assisted multicore fiber
...Show More Authors

View Publication
Scopus (17)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon May 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Image Retrieval Based on Coefficient Correlation Index
...Show More Authors

Image retrieval is an active research area in image processing, pattern recognition, and
computer vision. In this proposed method, there are two techniques to extract the feature
vector, the first one is applying the transformed algorithm on the whole image and the second
is to divide the image into four blocks and then applying the transform algorithm on each part
of the image. In each technique there are three transform algorithm that have been applied
(DCT, Walsh Transform, and Kekre’s Wavelet Transform) then finding the similarity and
indexing the images, useing the correlation between feature vector of the query image and
images in database. The retrieved method depends on higher indexing number. <

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Al-kindy College Medical Journal
A Population-Based Study on Agreement between Actual and Perceived Body Image
...Show More Authors

Background: Obesity tends to appear in modern societies and constitutes a significant public health problem with an increased risk of cardiovascular diseases.

Objective: This study aims to determine the agreement between actual and perceived body image in the general population.

Methods: A descriptive cross-sectional study design was conducted with a sample size of 300. The data were collected from eight major populated areas of Northern district of Karachi Sindh with a period of six months (10th January 2020 to 21st June 2020). The Figure rating questionnaire scale (FRS) was applied to collect the demographic data and perception about body weight. Body mass index (BMI) used for ass

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Correlation between exoplanet and star metallicity
...Show More Authors

The metallicity [Fe/H] for several stars accompanied by Extra-solar planets were calculated and plotted as a function of stars mass (M*). Results showed that masses of Extra-solar planets stars are well correlated with their metallicity .This relation could be explained by the equation: Y=-0.0045x + 0.065. The metallicity limit is found to be in the range of (0.18 to 0.3), relative to the mass limit in the range of (0.76 to 1.44) MSun.
This criteria is a good tool that can be used by observers who are aiming for detecting Extra-solar planets

View Publication Preview PDF
Publication Date
Tue Jul 01 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Serum Leptin levels in ovarian polycystic disease and its correlation to body weight
...Show More Authors

Background: Poly cystic ovary syndrome is a common disorder in women of reproductive age, it is associated with disturbance of reproductive, endocrine and metabolic functions. The pathophysiology of PCOS appears to be multifactorial and polygenic. Leptin seems to play an important role in pathophysiology of PCOS especially in women with BMI ≥25kg/m2. Objectives: To assess leptin level in both PCOS and healthy women and explore the relation to their body weight and body mass index. Patient and Methods: A total of 120 women were enrolled in this study, 60 women (50%) had PCOS (study group) and the reminder 60 women (50%) were healthy women and considered as control group. BMI was calculated first. Both groups were further sub

... Show More
Preview PDF
Crossref (2)
Crossref