Preferred Language
Articles
/
JBeys44BVTCNdQwCtFcG
Spectrophotometric Determination of Promethazine Hydrochloride by In (III)
...Show More Authors

A simple, rapid and sensitive spectrophotometirc method for the determination of trace amounts of promethazine hydrochloride in the aqueous solution is described. The method is based on the complexation of promethazine hydrochloride with In (III) in the presence of sodium hydroxide to form an soluble product with maximum absorption at 304nm. Beer’s law is obeyed over the concentration range of (2- 20μg/ml) with molar absorptivity of (1.92× 103 L.mol-1 .cm -1 ). The optimum conditions for all development are described and the proposed method has been successfully applied for the determination of promethazine hydrochloride in bulk drug.

Publication Date
Mon Aug 26 2019
Journal Name
Global Proceedings Repository American Research Foundation
Preparation, Spectra and Biological Properties of Transition Metals ((III) and (II) Mixed - Ligand Complexes with 5-Chlorosalicylic Acid and L-Valine
...Show More Authors

Mixed ligand metal complexes of CrIII, FeIII,II, NiII and CuII have been synthesized using 5-chlorosalicylic acid (5-CSA) as a primary ligand and L-Valine (L-Val) as secondary ligand. The metal complexes have been characterized by elemental analysis, electrical conductance, magnetic susceptibility measurements and spectral studies. The electrical conductance studies of the complexes indicate their electrolytic nature. Magnetic susceptibility measurements revealed paramagnetic nature of the all complexes. Bonding of the metal ion through –OHand –COOgroups of bidentate to the 5-chlorosalicylic acid and through –NH2 and –COOgroups of bidentate to the L-valine by FT-IR studies . The agar diffusion method has been used to study the antib

... Show More
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 22 2023
Journal Name
Iasr Journal Of Agriculture And Life Sciences
Determination of some heavy metals concentration in selected liquid soap, fruit and vegetable sterilizers used in Baghdad, Iraq
...Show More Authors

Detergent is one of the pollutants that poses significant threats to ecological systems. Detergents can also dissolve in wastewater and negatively impact the efficiency of wastewater treatment facilities. They are used for a variety of functions, most notably hygiene, and are an integral aspect of human life. This means that there are a variety of routes by which detergent components can reach the environment. In this Study, twenty-three detergent samples from local markets in Baghdad. The aim of this study is to investigate the concentration of heavy metals Cobalt (Co), Chromium (Cr),Lead (Pb),Zinc (Zn), Iron (Fe) and Cadmium (Cd) in some detergents using Atomic Absorption Spectrophotometer. The results of the concentration of heavy elemen

... Show More
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
Exploiting the diazotization reaction of 4- minoacetophenone for Methyldopa determination.
...Show More Authors

Based on the diazotization reaction of 4-aminoacetophenone with sodium nitrite in acid medium to form diazonium salt, which was coupled with Methyldopa to form a violet reddish soluble azo dye with maximum absorbance at 560 nm,a batch procedure had been developed for the estamination of Methyldopa. Under optimum experimental parameters affecting on the development and stability of the colored product, Beer´s law obeyed in the range (0.5-45) ?g.ml-1 with a correlation coefficient (0.9979).The proposed method was successfully applied to the determination of Methyldopa in either pure form and in commercial brands of pharmaceuticals, no interference was observed from common excipients in the formulations. The analytical results obtained by app

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Geological Journal
A Review of Historical Studies for Water Saturation Determination Techniques
...Show More Authors

Water saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artific

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
linear equivalence determination of key-stream sequence using Z-Transform
...Show More Authors

the research ptesents a proposed method to compare or determine the linear equivalence of the key-stream from linear or nonlinear key-stream

View Publication Preview PDF
Publication Date
Fri Sep 19 2025
Journal Name
Journal Of Engineering
Assessment of Equivalent Grain Diameter for Soil Specific Surface Determination
...Show More Authors

View Publication
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Determination The Effect of ZnO on Iraqi Bentonite Surface Properties
...Show More Authors

Bentonite is widely used in industrial applications. The present study reports the effect of adding different weights of ZnO to the Iraqi bentonite, on surface area, pore volume and real density. These surface properties were evaluated for pure and modified bentonite. The modification was made by adding different ZnO weights such as; ( 0.5%, 1%, 5%, 10% ). The effect of heat exposing for all modified clay samples at 500 ?C have been also evaluated. The results show that the addition of 0.5% ZnO leads to increase the surface area percentage about 36%, increase pore volume percentage about 5.48% and increase the real density percentage about 27.116%. When the samples exposed to 500 ?C, their surface area and pore volumes have been decreased a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Determination the Wheat Weight and Volume: Mathematical Approach
...Show More Authors
Abstract<p>Grain size and shape are important yield indicators. A hint for reexamining the visual markers of grain weight can be found in the wheat grain width. A digital vernier caliper is used to measure length, width, and thickness. The data consisted of 1296 wheat grains, with measurements for each grain. In this data set, the average weight (We) of the twenty-four grains was measured and recorded. To determine measure of the length (L), width (W), thickness (T), weight (We), and volume(V). These features were manipulated to develop two mathematical models that were passed on to the multiple regression models. The results of the weight model demonstrated that the length and width of the grai</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref