Preferred Language
Articles
/
JBdeNZIBVTCNdQwCGagR
Formulation and Evaluation of Immediate-Release Oral Tablets Containing Magnesium Aluminum Silicate-Loaded Simvastatin
...Show More Authors

Background: Simvastatin (SIM) is a lipid-lowering agent to prevent disorders caused by clogged blood vessels. Because of its low solubility, it has low bioavailability. The adsorption technique is effective in improving drug solubility and dissolution rate. Objective: To use magnesium aluminum silicate (MAS) as an adsorbent in combination with Soluplus® as a hydrophilic polymer to formulate SIM as immediate-release tablets (IRTs). Methods: We used the solvent evaporation method to make MAS-loaded SIM in the presence of Soluplus®, making sure that the ratio of SIM to MAS to SOLU was 1:6:3. We then used this mixture to make IRTs. Using the direct compression method, we made all of the SIM-IRT formulas. We used diluents like Avicel®PH102, Avicel®PH101, and starch, as well as super disintegrants like Crospovidone (CP), Croscarmellose sodium (CCS), and sodium starch glycolate (SSG). We evaluated these formulas for their weight variation, hardness, friability, disintegration time, drug content, and dissolution profile. Results: We prepared the tablet formula (T5) using MAS-loaded SIM, Avicel®PH102 as a diluent, and CCS 3% as a super disintegrant. This formula showed the shortest disintegration time (0.61 min) and best drug release in phosphate buffer pH 7.0, releasing more than 80% of the drug within 30 minutes. Conclusion: Using suitable excipients, adsorption was an efficient method to enhance the solubility of SIM for preparation as IRTs.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Study of the Porosity of Certain pharmaceutical Tablets using Mercury Intrusion Porosimeter
...Show More Authors

Porosity and pore structure are important characteristics of pharmaceutical tablets, since they influence the physical properties, such as mechanical strength, density and disintegration time. This paper is an attempt to investigate the pore structure of four different paracetamol tablets based on mercury porosimetry. The intrusion volumes of mercury were used to calculate the pore diameter, pore volume and pore size distribution. The result obtained indicate that the variation of the pore volume in the tablets followed the sequence:- S.D.I. Iraq? Pharmacare,Dubai-U.A.E.? Bron and Burk(UK) London?Lark Laboratories(India), while the variation of surface area followed the sequence:- S.D.I. Iraq? Lark Laboratories(India)? Pharmacare,Dubai-U.A

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 05 2019
Journal Name
International Journal Of Nanoelectronics And Materials
Characterization and Responsivity of Graphene Loaded Zinc Sulphide within Visible Light Spectrum
...Show More Authors

In this study, the nanocrystal-ZnS-loaded graphene was synthesized by a facile coprecipitation route. The effect of graphene on the characterization of Zinc Sulphide (ZnS) was investigated. The X-ray Diffraction (XRD) results reveal that ZnS has cubic system while hexagonal structure which is observed by loading graphene during the preparation of ZnS. Energy Dispersive X-ray Spectroscopy (EDS) analysis proved the presence of all expected elements in the prepared materials. Nanosize of fabricated materials has been measured using Scanning Electron Microscopy (SEM) technique. This study also found that the graphene plays a critical role in lowering the optical energy gap of ZnS nanoparticles from 4 eV to 3.2 eV. The characterization of detec

... Show More
Scopus (2)
Scopus
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Assessment of Bearing Capacity and Settlement Characteristics of Compacted Clay Soil Reinforced by Sand Dune and Sodium Silicate Columns
...Show More Authors

Abstract The present work aims to study the performance of reinforced compacted clay soil by sand columns stabilized with sodium silicate to obtain more solid columns than the surrounding soil. The experimental work was carried out by using a lab model to evaluate the performance of both the floating and end bearing sand columns. The results showed that the improvement ratio for the soil reinforced with sand columns stabilized with sodium silicate reached 390% for the type of floating columns and 438% for end bearing columns.

View Publication
Crossref (4)
Crossref
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A study of the Rate of Sedimentation of Magnesium Hydroxide Obtained from Bittern
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Study Analytical of The Effect Magnesium ion Concentration to Determination the Total Hardness And Comparison Spectrophotometry
...Show More Authors

The determination hardness in water raised to rivers caused several problem in the validity of the water used depends on where determination ions concentration calcium and magnesium in salts carbonate and sulfate , this possibility of separation between of these ions and the resulting impact on concentration and determination the degree of hardness water and appreciation between the insolvent water quality . It study the effect of the impact of concentration magnesium ion in determination the quality of the water has turned out to be Mg concentration more than 60% of the total content of hardness is borderline in hardness effect the determination. Adopted in this research determination the ions in two method titration by EDTA solution and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Erythrocyte Magnesium Levels in type I and type II Iraq diabetic patients effect of antidiabetic treatment
...Show More Authors

Background: Direct measurement of intracellular magnesium using erythrocytes has been suggested as a sensitive indicator for the estimation of body magnesium store. Marked depletion in plasma and erythrocyte magnesium levels was particularly evident in diabetic patients with advanced retinopathy and poor diabetic control. While insulin has been shown to stimulate erythrocyte magnesium uptake, hyperglycemia per se suppressed intracellular magnesium in normal human red cells.
Aim of the study: To investigate the erythrocyte magnesium level in Iraqi type I and II diabetic patients, with specific emphasis on the effect of both, metabolic control and the type of antidiabetic treatments.
Methods: Sixty two diabetic patients (7 with type

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Study of Main Factors Affecting the Leakage of Aluminum into the Food Wrapped in Aluminum Foil During Cooking
...Show More Authors

Different cooking conditions were examined for aluminum content in food cooked while wrapped with aluminum foil. The influence of each anticipated factor (the acidity of the cooking medium, type of acids normally used in cuisines namely acetic and tartaric acids, various cooking temperatures, influence of the presence of sodium chloride salt, the effect of cooking oil, and the length of time of cooking) was studied thoroughly as a function of aluminum degraded out of the aluminum foils to the medium. The experimental samples were digested with nitric acid upon fulfillment of examining each factor separately before quantifying aluminum with the sensitive technique of atomic absorption spectroscopy. The outcomes of the study have shown that t

... Show More
View Publication Preview PDF
Scopus
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect Use of Two Chemical Compounds Sodium Nitrate and Sodium Silicate as Corrosion Inhibitor to Steel Reinforcement
...Show More Authors

Corrosion of steel reinforcement is one of the biggest problems facing all countries in the world like bridges in the beach area and marine constructions which lead to study these problems and apply some economical solutions. According to the high cost of repair for these constructions, were studied the effect of using kind of chemical compounds sodium nitrite(NaNO2) and sodium silicate(Na2SiO3) as corrosion inhibitors admixture for steel bars that immersed partially in electrolyte solution (water + sodium chloride in 3% conc.) (Approximately similar to the concentration of salt in sea water). The two inhibitors above added each one to the electrolyte solution at concentrations (0.5%, 1% and 2%) for both

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
The Immediate And Intermediate Results Of Percutaneous Balloon Aortic Valvuloplasty In Patients With Congenital Valvular Aortic Stenosis
...Show More Authors

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .

Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .

Type of the study: A prospective study.

Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.

Results

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 03 2015
Journal Name
Al- Kindy College Medical Journal
Proximal palmar mini-incision carpal tunnel release technique
...Show More Authors

Background: Carpal tunnel syndrome is the most common entrapment neuropathy in humans today. For patients in whom conservative treatment fails, surgical decompression is indicated. Various surgical techniques are becoming increasingly popular. Due to the rapid postoperative recovery shown after endoscopic operations, proximal palmar mini-incision for carpal tunnel release is a comparative alternative. Methods: Ninety four patients [113 hands] with a carpal tunnel syndrome underwent carpal tunnel release through a 1-cm longitudinal incision made just over the distal flexor crease. The self- administered Boston Questionnaire was used to assess the severity of patients’ symptoms and their functional status, both before and after the surgical

... Show More
View Publication Preview PDF