This systematic review aimed to investigate the relation between orthodontic treatment (OT) and the incidence of the gingival black triangle (GBT) after completing treatment with a fixed orthodontic appliance, as well as the associated risk factors and the level of alveolar bone. Electronic and hand searches were conducted in three electronic databases for relevant articles published up to March 2022. Retrieved articles went through a two-step screening procedure, and the risk of bias (RoB) was assessed by the Joanna Briggs Institute checklists. The incidence of GBT after OT was set as the primary outcome, while the secondary outcomes were the risk factors associated with GBT and alveolar bone loss following OT. Out of 421 papers, 5 were selected for the final analysis. The RoBs of three studies were moderate and the remaining two were low. The incidence of GBT following OT ranged from 38% to 58%. In addition, three studies reported that alveolar bone loss was reduced significantly following OT and associated with GBT, while one study found the opposite. Regarding the risk factors associated with GBT, the reported results attributed GBT to several factors including age, tooth-related factors, treatment duration, and soft tissue factors. The analysis indicates an increased incidence of GBT following OT; however, a firm conclusion cannot be drawn. Additionally, it was not possible to reach a consensus on risk factors associated with GBT due to the heterogeneity of the data. Therefore, further randomized clinical trials are highly recommended to draw a firm conclusion.
Dora petroleum refinery waste water is the one of the important source of pollution by priority pollutant aromatic compound discharged to Tigris river in Iraq. the station has waste water treatment unit contains many treatment subunits The most important sub units is :skimmer units ,physiochemical unit ,daf unit, biological unit. The aim of research project is to study the ability of unit to remove the priority pollutant aromatic compound and follow up these compounds in river to study ability of river to self removal. A solid phase extraction (SPE) followed by high performance liquid chromatography-ultra violet (HPLC-UV) technique is depicted for the quantitative estimation of benzidines and phenols. Experimental studies were performed to
... Show MoreIn this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation). A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow
... Show MoreIn the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater. The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.
Aluminum foil cover around the re
... Show MoreObjectives: Teenage pregnancy with gestational diabetes mellitus (GDM) offers a real challenge to the health system and needs a special care. We aimed to evaluate possible obstetrical and neonatal adverse events of different treatment protocols in adolescent GDM including lifestyle, metformin (MTF), and insulin. Methods: All teen pregnant women ≤ 19 years old visiting Baghdad Teaching Hospital throughout four years (from June 1, 2016 till May 31, 2020) diagnosed with GDM were included in this cohort study and followed-up closely throughout pregnancy and after delivery. Included adolescents were put on lifestyle alone during the first week of presentation. Adolescents who reached target glucose measurements were categorized i
... Show MoreThe study aims mainly to evaluate the performance of Sharq Dijila water treatment plant in removing turbidity for the period of 1-4-2001 to 31-3-2004. Daily data for turbidity of raw, clarified, filtered, and supplied water were analyzed. The results of the study showed that there is a wide variation in turbidity levels of raw water fluctuating between 10-1000 NTU with mean value of 41.3 NTU. Turbidity values of the clarified water varied between 1.4-77 NTU. Based on the turbidity value of 10 NTU and 20 NTU (the design maximum turbidity) the readings gave an acceptable percentage of 32.4% and 86% respectively. The turbidity of filtered water ranged between 0.2-4.5 NTU which are completely in compliance with Iraqi and WHO standards. In ac
... Show MoreWhen laser light incident on biological tissue, it is either reflected from the
surface of the tissue (e.g. the skin) or scattered inside the tissue or absorbed .The laser light will be
absorbed by water, hemoglobin and melanin. Absorption is also highly dependent on wave-length of
laser radiation. The absorbed light is converted into kinetic energy leading to laser effect that when
appropriately applied can produce reaction ranging from incision, vaporization to coagulation. Aim of
the study: To evaluate the efficiency of diode Laser 810 ± 20nm in treatment of oral lesions. Methods:
6 patients (2 females and 4 males) with different oral lesions were treated in the hospital of specialized
surgeries by the use of dio
Abstract 20 patients with osteoarthritis of the knee joint were treated by electrical stimulation in the form of 6 sessions every other day each sessions of diphase fixe (DF) for 4 minutes followed by rest for 4 minutes then treated with a monophase fixe (MF) for 2 minutes. By clinical & statistical analysis ( P value < 0.05) we conclude that the electrical stimulation is effective as one method in the treatment of osteoarthritis.
Throughout the ages,the methods of human production, exchange, and communication have not changed,and lifestyles have not witnessed rapid and comprehensive changes except since the presence of advanced and modern technologies for information and communication, which led to the emergence of new patterns of intellectual works and innovations that are dealt with and circulated through the virtual medium.These innovations are in many legal disputes, and domain names are one of the most important foundations of information networks, as they are the key to entering the virtual world and distinguishing websites. Because of the novelty of domain names,many attacks have occurred on them, which are closely related to intellectual property rights. And
... Show MoreThe objective of this study is to investigate the application of advanced oxidation processes (AOPs) in the treatment of wastewater contaminated with furfural. The AOPs investigated is the homogeneous photo-Fenton (UV/H2O2/Fe+2) process. The experiments were conducted by using cylindrical stainless steel batch photo-reactor. The influence of different variables: initial concentration of H2O2 (300-1300mg/L), Fe+2(20-70mg/L), pH(2-7) and initial concentration of furfural (50-300 mg/L) and their relationship with the mineralization efficiency were studied.
Complete mineralization for the system UV/H2O2/Fe+2 was achieved at: initi
... Show More