Preferred Language
Articles
/
JBb3H4cBVTCNdQwCSTko
Improvement of Alert System against Tampering and Theft in Surveillance Cameras
...Show More Authors

Use of Surveillance cameras in houses and markets became common, that resulted to minimize theft and make it a difficult task because it let recording and viewing what is going around. The wide application of these cameras, pushed thieves to seek new ways for abolition of the surveillance system and digital recording of events, such as cutting the signal wire between the camera and Digital video recorder or changing the direction of the camera away from the focus spot or damaging the camera or steal the device which means the loss of the recorded media. This paper focuses on such abolitions and fixed it by suggesting a way to notify the administrator immediately and automatically by Email about any violation of the system using MATLAB, which allow fast action by the administrator to fix such tampering. The results show that selecting of threshold equal to two was fair in detecting motion and value of five, in case of changing the camera direction through testing of fast and slow motions.

View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Structural and D.C. conductivity investigation of the ternary alloy System a-AlXGa1-x As:H films prepared by new deposition method
...Show More Authors

In this paper Alx Ga1-x As:H films have been prepared by using new deposition method based on combination of flash- thermal evaporation technique. The thickness of our samples was about 300nm. The Al concentration was altered within the 0 x 40.
The results of X- ray diffraction analysis (XRD) confirmed the amorphous structure of all AlXGa1-x As:H films with x  40 and annealing temperature (Ta)<200°C. the temperature dependence of the DC conductivity GDC with various Al content has been measured for AlXGa1-x As:H films.
We have found that the thermal activation energy Ea depends of Al content and Ta, thus the value of Ea were approximately equal to half the value of optical gap.

View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Development of Iraqi License Plate Recognition System based on Canny Edge Detection Method
...Show More Authors

In recent years, there has been expanding development in the vehicular part and the number of vehicles moving on the road in all the sections of the country. Vehicle number plate identification based on image processing is a dynamic area of this work; this technique is used for security purposes such as tracking of stolen cars and access control to restricted areas. The License Plate Recognition System (LPRS) exploits a digital camera to capture vehicle plate numbers is used as input to the proposed recognition system. Basically, the developing system is consist of three phases, vehicle license plate localization, character segmentation, and character recognition, the License Plate (LP) detection is presented using canny

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Nov 02 2018
Journal Name
Aci Special Publication
CFRP Repairing System at Openings in Reinforced Concrete T-Beams Cracked by Impact Loads
...Show More Authors

View Publication
Publication Date
Sun Oct 01 2017
Journal Name
13th International Symposium On Fiber-reinforced Polymer Reinforcement For Concrete Structures Frprcs 13
CFRP Repairing System at Openings in Reinforced Concrete T-Beams Cracked by Impact Loads
...Show More Authors

Publication Date
Mon Nov 01 2021
Journal Name
Energies
Solidification Enhancement in a Triple-Tube Latent Heat Energy Storage System Using Twisted Fins
...Show More Authors

This work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem

... Show More
View Publication
Scopus (40)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Tue Oct 29 2019
Journal Name
Journal Of Engineering
Demand Priority in a Power System With Wind Power Contribution Load Shedding Scheme Based
...Show More Authors

The load shedding  scheme has been extensively implemented as a fast solution for unbalance conditions. Therefore, it's crucial to investigate supply-demand balancing in order to protect the network from collapsing and to sustain stability as possible, however its implementation is mostly undesirable. One of the solutions to minimize the amount of load shedding is the integration renewable energy  resources, such as wind power, in the electric power generation could contribute significantly to minimizing power cuts as it is ability to positively improving the stability of the electric grid. In this paper propose a method for shedding the load base on the priority demands with incorporating the wind po

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Wed May 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Mesoporous Silica MCM-41 as a Carriers Material for Nystatine Drug in Delivery System
...Show More Authors

In the present study, MCM-41 was synthesis as a carrier for poorly drugs soluble in water, by the sol-gel technique. Textural and chemical characterizations of MCM-41 were carried out by X-ray diffraction (XRD), Fourier transform infrared (FTIR), scanning electron microscope (SEM), and thermal gravimetric analysis (TGA). The experimental results were analyzed mesoporous carriers MCM-41. With maximum drug loading efficiency in MCM-41 determined to be 90.74%. The NYS released was prudently studied in simulated body fluid (SBF) pH 7.4 and the results proved that the release of NYS from MCM-41 was (87.79%) after 18 hr. The data of NYS released was found to be submitted a Weibull model with a correlation coefficient of (0.995). The Historical

... Show More
View Publication Preview PDF
Crossref (14)
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
International Journal Of Heat And Mass Transfer
Melting enhancement in triplex-tube latent thermal energy storage system using nanoparticles-fins combination
...Show More Authors

View Publication
Scopus (199)
Crossref (192)
Scopus Clarivate Crossref
Publication Date
Tue Jan 14 2025
Journal Name
South Eastern European Journal Of Public Health
Deep learning-based threat Intelligence system for IoT Network in Compliance With IEEE Standard
...Show More Authors

The continuous advancement in the use of the IoT has greatly transformed industries, though at the same time it has made the IoT network vulnerable to highly advanced cybercrimes. There are several limitations with traditional security measures for IoT; the protection of distributed and adaptive IoT systems requires new approaches. This research presents novel threat intelligence for IoT networks based on deep learning, which maintains compliance with IEEE standards. Interweaving artificial intelligence with standardization frameworks is the goal of the study and, thus, improves the identification, protection, and reduction of cyber threats impacting IoT environments. The study is systematic and begins by examining IoT-specific thre

... Show More
View Publication
Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
MODIFIED ALVARADO SCORING SYSTEM. HOW MUCH HELPFUL?
...Show More Authors

Background:-The Modified Alvarado Scoring
System (MASS) has been reported to be a cheap
and quick diagnostic tool in patients with acute
appendicitis. However, differences in diagnostic
accuracy have been observed if the scores were
applied to various populations and clinical settings.
Objectives:- The purpose of this study was to
evaluate the diagnostic value of Modified Alvarado
Scoring System in patients with acute appendicitis
in our setting.
Methods:-one hundre twenty eight patients, were
included in this study, admitted to Al-Kindy
teaching hospital from June 2009 to June 2010.
Patients’ age ranged from 8 to 56 years (21±10)
they were divided into three groups; paediatrics,
child bear

... Show More
View Publication Preview PDF