Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly into three main groups, twenty roots in each group. The roots were instrumented with different rotary systems using crown down technique according to the groups: (Group I) was instrumented with WaveOne files. (Group II) was instrumented with ProTaper Next system and (Group III) was instrumented with ProTaper Universal system. For each group the same irrigation regimen was used, 3 mL of 5.25% sodium hypochlorite and 3 mL of 17% EDTA to remove the smear layer. Then, Group I was also subdivided randomly into two subgroups of ten samples each, (Group I A) obturated with single cone gutta-percha and (Group I B) filled with GuttaFusion®. Group II was divided into (Group II A) obturated with single cone gutta-percha and (Group II B) filled with GuttaFusion®. Group III was divided into (Group III A) obturated with single cone gutta-percha and (Group III B) obturated with GuttaFusion®. In the present study, TotalFill BC sealer was used for all the tested groups. Then, the roots were embedded in clear acrylic resin and each root sectioned into three sections of 2mm thick (apical, middle and coronal). The push-out bond strength values represented by (MPa) unit was calculated by dividing the load on the surface area and the last was measured in collaboration with AutoCAD system software program. Failure mode analysis was carried out to examine the type of failure in each sample by using a stereomicroscope. Results: The results showed highly significant differences among the main groups that instrumented with different rotary systems (WaveOne, ProTaper Next and ProTaper Universal system). There were highly significant differences between the two obturation techniques of the subgroups (single cone gutta-percha versus GuttaFusion®). However; Gutta-Fusion® showed highest bond strength value than single cone obturation technique. The coronal third slices of all groups showed highest value of bond strength in comparison to the middle thirds and apical thirds. In the meantime, the middle third slices showed bond strength higher than that of the apical thirds for all groups. Statistical analysis was performed by using two way ANOVA and LSD tests. Conclusions: The instrumentation techniques and the obturation materials significantly affected the push-out bond strength values of obturation system. The highest value was appointed in root canals instrumented with ProTaper Universal System; obturated with GuttaFusion® and BC sealer, whereas, the lowest bond strength was appeared at canals instrumented with ProTaper Next; obturated with single cone gutta-percha and BC sealer.
Buried pipeline systems are commonly used to transport water, sewage, natural oil/gas and other materials. The beneficial of using geogrid reinforcement is to increase the bearing capacity of the soil and decrease the load transfer to the underground structures.
This paper deals with simulation of the buried pipe problem numerically by finite elements method using the newest version of PLAXIS-3D software. Rajkumar and Ilamaruthi's study, 2008 has been selected to be reanalyzed as 3D problem because it is containing all the properties needed by the program such as the modulus of elasticity, Poisson's ratio, angle of internal friction. It was found that the results
... Show MoreObjective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show MoreOne of the most important problems in tablet process is to control the flow of the catalyst through the hopper; Controlling the flow can be done either by changing the size of particles or added the different lubricant (stearic acid, starch, graphite) or blending of different lubricants. The study showed that we can control (increase or decrease) on the flow of the catalyst through the hopper by blending different lubricants for the constant percentage. The flow increasing when particles size (0.6 mm) and then decrease with or without lubricants, no effect on flow when particles size lower than (0.2 mm) with use that lubricants, and good flow on (0.4 mm) when use stearic acid and starch.
Introduction: We aimed to assess the impact of adhesive and wires types on the tensile bond strength of fixed lingual retainers. Methods: A total of 160 intact bovine teeth were collected, cleaned, stored in 25% sodium hypochlorite, and randomly assigned to two groups based on the adhesive type: a two-step adhesive and a one-step adhesive. Each group was further divided into four subgroups based on the type of lingual retainer wire, which included (A) 8-strand braided stainless steel wire, (B) three-strand titanium retainer wire, (C) stainless steel chain, and (D) fiber-reinforced retainer. A tensile bond strength test was conducted using a universal testing machine at a controlled speed of 10 mm/min. Result: The 8-strand braided stainles
... Show MoreIt is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th
... Show MoreEfficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)
Background: Polymorphisms in the TNF-α gene affect the development and progression of rheumatoid arthritis. Objective: To investigate the associations between (-806 T/C) and (-857 T/C) SNPs with rheumatoid arthritis severity and susceptibility in a sample of Iraqi patients. Methods: A case-control study was conducted in Baghdad, Iraq. Twenty healthy controls and 63 patients confirmed to be newly diagnosed with rheumatoid arthritis were included. Those are divided into two groups (patients and controls), and the patients were further subdivided into severe and mild-moderate groups. Samples from those participants were analyzed for clinical and inflammatory parameter measurements. Genotyping by the Sanger method was performed to stu
... Show MoreThis study aims to evaluate the influence of the air abrasion of dentin on the shear bond strength of lithium disilicate using three different types of luting cements. Sixty cylindrical specimens were milled from lithium disilicate CAD/CAM blocks (IPSe.max CAD). Sixty sound human maxillary premolar teeth were decoronated to the level of peripheral dentin, then randomly divided into three groups according to the type of luting cement used for the cementation of the lithium disilicate specimens (n = 20); Group A: Glass ionomer cement (Riva Self- Cure); Group B: Adhesive resin cement (Rely X Ultimate); Group C: Self-adhesive resin cement (Rely X U200). Each group was then further subdivided into two subgroups (n=10); Subgroups AI, BI, and CI,
... Show MoreThis study aimed to study the effect of Ziziphus spina christi Aqueous cold and Alcoholic leaves and fruits extracts on the growth and activities of the following types of bacteria :( Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Streptococcus pyogenes ). The results appeared outweigh the alcoholic extract of leaves and fruits of Sidr that prepared by saxholate extractor by addition of ethanol 95% significant superiority as compared with aqueous extract that prepared by using distilled water as was its influence inhibitor to the growth and effectiveness of bacteria , about the treatment of in-vivo to cause injury to these types of bacteria diagnosed laboratory mice and treated with alcoholic extract of the leaves o
... Show MoreIn this research a new system identification algorithm is presented for obtaining an optimal set of mathematical models for system with perturbed coefficients, then this algorithm is applied practically by an “On Line System Identification Circuit”, based on real time speed response data of a permanent magnet DC motor. Such set of mathematical models represents the physical plant against all variation which may exist in its parameters, and forms a strong mathematical foundation for stability and performance analysis in control theory problems.