Preferred Language
Articles
/
J4YddYYBIXToZYAL14sq
THE INFLUENCE OF CHEMICAL COMPOSITION OF ASPHALT CEMENT ON THE PHYSICAL AND RHEOLOGICAL PROPERTIES
...Show More Authors

Failure in asphalt mixture and distress in pavement are major issues to roads infrastructure. Selecting an appropriate chemical composition of asphalt cement is a key component in avoiding these issues. This work aimed to investigate the effect of the chemical composition of different polar fractions on the rheological and physical properties of asphalt cement. Four types of asphalt cement with penetration grades of 20/30, 40/50, 60/70 and 85/100 were divided into four fractions. Complex shear modules, rutting resistance and rotational viscosity of the asphalt cement were determined by using a Dynamic Shear Rheometer and a Rotation Viscometer, respectively. The results show that an increase in the asphaltene content and Gastel index resulted in an increase in the complex shear modulus, rutting resistance and rotation viscosity of the asphalt cement. The addition of more asphaltene content and Gastel index resulted in a decrease in penetration and ductility values. This observation also revealed that asphalt cement with higher asphaltene content had higher stiffness. The findings from this study can assist in the understanding of the behavior of asphalt cements in its original state and improve the performance of asphalt cement for pavement applications.

Publication Date
Mon Sep 20 2021
Journal Name
Key Engineering Materials
Heat Treatment at Different Temperatures and its Effect on the Optical Properties of Pure PMMA and PMMA-Coumarin
...Show More Authors

The effect of thermal treatment on optical constants of pure PMMA and with addition (15 and 35) ml of coumarin at different temperatures (100, 110 and 120) C0 for 1 hour were investigated. Cast method used to prepares films of pure PMMA and PMMA with (15 and 35) of coumarin. UV/VIS spectrometer technique used to measure the absorption spectra for these films. The optical constant (absorption spectra and absorption coefficient) don’t changes after applied temperatures in pure PMMA film but the optical constant (absorption spectra and absorption coefficient) in PMMA with (15 and 35) ml of coumarin increased with applied temperatures. The optical energy gap of pure PMMA and PMMA with (15 and 35) ml of coumarin sl

... Show More
View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Al-kindy College Medical Journal
Ultrasound of the Rotator Cuff: A Comparison of Ultrasonographic and Physical Examination Finding in Seventy Consecutive Cases
...Show More Authors

Background : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome. Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ultrasonogr

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Ultrasound of the Rotator Cuff: A Comparison of Ultrasonographic and Physical Examination Finding in Seventy Consecutive Cases
...Show More Authors

Background : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults
Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome.
Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ul

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Effect of annealing temperature on the optical properties of (Cu2S)100-x( SnS2 )x thin films
...Show More Authors

Thin films of (Cu2S)100-x( SnS2 )x at X=[ 30,40, &50)]% with thickness (0.9±0.03)µm , had been prepared by chemical spray pyrolysis method on glass substrates at 573 K. These films were then annealed under low pressure of(10-2) mbar ,373)423&473)K for one hour . This research includes , studying the the optical properties of (Cu2S)100-x-(SnS2)x at X=[ 30,40, &50)]% .Moreover studying the effect of annealing on their optical properties , in order to fabricate films with high stability and transmittance that can be used in solar cells. The transmittance and absorbance spectra had been recorded in the wavelength range (310 - 1100) nm in order to study the optical properties . It was found that these films had direct optical band

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Effect of H2SO4/H2O Ratio on the Properties of Positive Electrode in Lead-acid Battery
...Show More Authors

The lead-acid battery has become so dependable in its used applications of automobile starting, emergency lighting and telecommunications, which left an impression that no further investigation is necessary or desirable. While there has been slow continuous improvements in lead-acid battery performance and mainly limited to design and material engineering. This work is mainly devoted to the properties of the active mass of the positive electrode and the acid/water ratio during the manufacturing process. A field study is carried out at the State Battery Manufacturing Company located in Baghdad, to prepare batches of lead mono-oxide with predefined quantities of liquid additives (i.e. sulfuric acid and water). Quality control and laborator

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
Advances In Materials Physics And Chemistry
The Effect of Zn Concentration on the Optical Properties of Cd10–xZnxS Films for Solar Cells Applications
...Show More Authors

ABSTRACT:In this paper, Cd10–xZnxS (x = 0.1, 0.3, 0.5) films were deposited by using chemical spray pyrolysis technique, the molar concentration precursor solution was 0.15 M/L. Depositions were done at 350°C on cleaned glass substrates. X-ray dif- fraction technique (XRD) studies for all the prepared film; all the films are crystalline with hexagonal structure .The optical properties of the prepared films were studied using measurements from VIS-UV-IR spectrophotometer at wave- length with the range 300 - 900 nm; the average transmission of the minimum doping ratio (Zn at 0.1%) was about 55% in the VIS region, it was decrease at the increasing of Zn concentration in the CdS films, The band gap of the doped CdS films was varied as 3.7, 3

... Show More
Preview PDF
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Influence of Nanofluid Flooding on Oil Displacement in Porous Media
...Show More Authors

Hydrocarbon displacement at the pore scale is mainly controlled by the wetness properties of the porous media. Consequently, several techniques including nanofluid flooding were implemented to manipulate the wetting behavior of the pore space in oil reservoirs. This study thus focuses on monitoring the displacement of oil from artificial glass porous media, as a representative for sandstone reservoirs, before and after nanofluid flooding. Experiments were conducted at various temperatures (25 – 50° C), nanoparticles concentrations (0.001 – 0.05 wt% SiO2 NPs), salinity (0.1 – 2 wt% NaCl), and flooding time. Images were taken via a high-resolution microscopic camera and analyzed to investigate the displacement of the oil at dif

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Iraqi Journal Of Agricultural Sciences 49 (4), 632-638‏
Influence of some organic fertilizers on date palm CV. Barhi
...Show More Authors

Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Influence of Fluoride Addition on Hydroxyapatite Prepared for Medical Applications
...Show More Authors

In this study, hydroxyapatite (HAP, Ca10(PO4)6(OH)2) has been prepared as bioceramic material with biological specifications useful to used for orthopedic and dental implant applications. Wet chemical processing seems to form the fine grain size and uniform characteristic nanocrystalline materials by the interstice factors controlling which affected the grain size and crystallinity in order to give good mechanical and/or constituent properties similar as natural bone. Fluorinated hydroxyapatite [4-6 wt% F, (FHA, Ca10(PO4)6(OH)2–Fx] was developed in new method for its posses to increased strength and to give higher corrosion resistance in biofluids than pure HAP moreover reduces the risk of dental caries. The phase's and functional groups

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref