In the present study, 1-ethyl -3-methyllimidazolium acetate ionic liquid is introduced for extractive desulfurization of Iraqi kerosene (1622ppm) and compared with 1-ethyl -3- methyllimidazolium tetrafloroborate. The effect of ionic liquid/ fuel ratio (1/9, 1/4, 1/2), temperature (25, 30,40oC), stirring speed (300,450rpm) and time (10, 30, 90, 180, 360 min) were studied. Sulfur compound analysis was performed using X-Ray fluorescence. The ionic liquid with acetate anion (OAc) showed better performance than tetrafloborate (BF4). The maximum extraction efficiency was 32% achieved at 1/2 IL/Fuel and 40oC after 90min. The oxidation step using hydrogen peroxide (8ml/200ml), catalyzed by acetic acid (2ml) and followed by ionic liquid extraction h
... Show MoreThe rapid development of Internet of Things (IoT) devices and their increasing numbers have caused a tremendous increase in network traffic and a wider range of cyber-attacks. This growing trend has complicated the detection process for traditional intrusion detection systems and heightened the challenges faced by these devices, such as imbalanced and large training data. This study presents a cohesive methodology of a series of intelligent techniques to prepare clean and balanced data for training the first (core) layer of a robust hierarchical intrusion detection system. The methodology was built by cleaning and compressing the data using an Autoencoder and preparing a strong latent space for balancing using a hybrid method that combines
... Show MoreThis paper proposes a new approach, of Clustering Ultrasound images using the Hybrid Filter (CUHF) to determine the gender of the fetus in the early stages. The possible advantage of CUHF, a better result can be achieved when fuzzy c-mean FCM returns incorrect clusters. The proposed approach is conducted in two steps. Firstly, a preprocessing step to decrease the noise presented in ultrasound images by applying the filters: Local Binary Pattern (LBP), median, median and discrete wavelet (DWT), (median, DWT & LBP) and (median & Laplacian) ML. Secondly, implementing Fuzzy C-Mean (FCM) for clustering the resulted images from the first step. Amongst those filters, Median & Lap
This paper proposes a new approach, of Clustering Ultrasound images using the Hybrid Filter (CUHF) to determine the gender of the fetus in the early stages. The possible advantage of CUHF, a better result can be achieved when fuzzy c-mean FCM returns incorrect clusters. The proposed approach is conducted in two steps. Firstly, a preprocessing step to decrease the noise presented in ultrasound images by applying the filters: Local Binary Pattern (LBP), median, median and discrete wavelet (DWT),(median, DWT & LBP) and (median & Laplacian) ML. Secondly, implementing Fuzzy C-Mean (FCM) for clustering the resulted images from the first step. Amongst those filters, Median & Laplace has recorded a better accuracy. Our experimental evaluation on re
... Show MoreThe synthesis and properties of two new series of compounds having 1,3-Oxazepineand 1,3-thiazole rings connected through azo linkage are reported. These compounds weresynthesized by the reaction of phthalic anhydride with Schiff bases. The molecular structuresof these compounds were verified by elemental analysis, FTIR and 1HNMR spectroscopy.The mesomorphic behaviors of these compounds were studied by optical polarizedmicroscopy (OPM) and differential scanning calorimetry (DSC). All compounds of the twoseries show liquid crystalline properties. The influence of the central oxazepine and thiazolerings and the terminal substituents on the type and temperature range of the mesomorphousproperties of these compounds has been elucidated
KE Sharquie, AA Noaimi, HA Al-Mudaris, Journal of Cosmetics, Dermatological Sciences and Applications, 2013 - Cited by 4