Preferred Language
Articles
/
IoYQqYYBIXToZYALv6OA
Numerical Study of Specially Shaped Slender RC Columns under Compressive Load
...Show More Authors
Abstract<p>In most Reinforced Concrete (RC) buildings, the cross-section size of rectangular columns that conventionally used in these structures is larger than the thickness of their partitions. Consequently, a part of the column is protruded out of the wall which has some architectural disadvantages. Reducing the column size by using high strength concrete will result in slender column, thus the stability problem may be occurred. The stability problem is difficult to be overcome with rectangular columns. This paper study the effectiveness of using new types of columns called Specially Shaped Reinforced Concrete (SSRC) columns. Besides, the use of SSRC columns provides many structural advantages when compared with traditional rectangular columns. This research was conducted to study the structural behavior of slender SSRC columns via nonlinear finite element analysis using Abaqus program. The study based on twenty-four RC column specimens of the same cross-sectional area and different shapes and Slenderness Ratios (SR). The results showed that the use of SSRC columns led to improve the strength by about 12% and reduce deformations as compared with the square-shaped specimen. However, the columns individually exhibited almost the same trend of decreasing the strength with increasing in SR. In general, a maximum loss in strength of about 10% was found when the SR increased to 40 and 35% for columns with SR of 80. Two design approaches were proposed to evaluate the strength of SSRC columns under concentric loading. The results obtained show a good structural response of SSRC columns as compared with square-shaped columns.</p>
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Space International Journal Of Space Studies In Architecture And Urban Design
Adaptive Reuse of Traditional Architecture under the Influence of Intelligent Systems
...Show More Authors

Publication Date
Fri Apr 24 2015
Journal Name
Plos One
Environmental Response and Genomic Regions Correlated with Rice Root Growth and Yield under Drought in the OryzaSNP Panel across Multiple Study Systems
...Show More Authors

View Publication
Scopus (31)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Optimum Reinforcement Depth Ratio for Sandy Soil Enhancement to Support Ring Footing Subjected to a Combination of Inclined-Eccentric Load
...Show More Authors

This work investigates the impacts of eccentric-inclined load on ring footing performance resting on treated and untreated weak sandy soil, and due to the reduction in the footing carrying capacity due to the combinations of eccentrically-inclined load, the geogrid was used as reinforcement material. Ring radius ratio and reinforcement depth ratio parameters were investigated. Test outcomes showed that the carrying capacity of the footing decreases with the increment in the eccentric-inclined load and footing radius ratio. Furthermore, footing tilt and horizontal displacement increase with increasing the eccentricity and inclination angle, respectively. At the same time, the increment in the horizontal displacement due t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Numerical and Experimental Investigations of the Effect of PVD and Vacuum Pressure on the Degree of Saturation
...Show More Authors

    Soft clays are generally characterized by low shear strength, low permeability and high compressibility. An effective method to accelerate consolidation of such soils is to use vertical drains along with vacuum preloading to encourage radial flow of water.  In this research numerical modeling of prefabricated vertical drains with vacuum pressure was done to investigate the effect of using vertical drains together with vacuum pressure on the degree of saturation of fully and saturated-unsaturated soft soils.  Laboratory experiments were conducted by using a specially-designed large consolidometer cell where a central drain was installed and vacuum pressure was applied. All tests were conducted

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 15 2023
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Detection the Phylogenetic groups of E. coli that isolated from diarrheal in children under five years and study their relationship of common serotypes in Baghdad hospitals.
...Show More Authors

Preview PDF
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Numerical Simulation of Water Distribution with Uptake Root in Drip Irrigation using Different Soil Hydraulic Models
...Show More Authors

Surface drip irrigation is one of the most conservative irrigation techniques that help control providing water directly on the soil through the emitters. It can supply fertilizer and providing water directly to plant roots by drippers. One of the essential needs for trickle irrigation nowadays is to obtain more knowledge about the moisture pattern under the trickling source for various types of soil with various discharge levels with trickle irrigation. Simulation numerical using HYDRUS-2D software, version 2.04 was used to estimate an equation for the wetted area from a single surface drip irrigation in unsaturated soil is taking into account water uptake by roots. In this paper, using two soil types were used, namely

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Numerical Investigation of Natural Convection Heat Transfer in Partially Filled Porous Enclosure Subjected to Constant Heat
...Show More Authors

Steady natural convection in a square enclosure with wall length (L= 20 cm) partially filled by saturated porous medium with same fluid (lower layer) and air (upper layer) is investigated. The conceptual study of the achievements of the heat transfer is performed under effects of bottom heating by constant heat flux (q=150,300,450,600W/m2 ) for three heaters size (0.2,0.14,0.07)m with symmetrically cooling with constant temperature on two vertical walls and adiabatic top wall. The relevant filled studied parameters are four different porous medium heights (Hp=0.25L,0.5L, 0.75L, L), Darcey number (Da1) 3.025×10-8 and (Da2) 8.852×10-4 ) and Rayleigh number range (60.354 - 241.41), (1.304×106 – 5.2166×106 ) for Da1 and Da2 cases respecti

... Show More
Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
International Journal Of Agriculture Environment And Food Sciences
Functional and numerical response of Hippodamia variegata (Goeze) (Coleoptera: Coccinellidae) on Macrosiphum rosae (L.) (Hemiptera: Aphididae)
...Show More Authors

In this study, functional and numerical response tests, which are important components in the selection of biological control agent, were carried out. In functional response trials, the amount of food consumed, attack rate (a) and handling time (Th) were calculated for each developmental period, depending on the number of preys given after 24 hours. The obtained results were evaluated with the Holling. In numerical response experiments, the development of the predator insect was examined depending on the number of preys given in certain numbers (5, 10, 20, 40 and 80) and the data were recorded. This phase of the trials continued until the individuals died. At this stage of the trials, the reproductive response of the p

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Apr 27 2023
Journal Name
Civileng
Numerical Modeling and Analysis of Strengthened Steel–Concrete Composite Beams in Sagging and Hogging Moment Regions
...Show More Authors

Strengthening of composite beams is highly needed to upgrade the capacities of existing beams. The strengthening methods can be classified as active or passive techniques. Therefore, the main purpose of this study is to provide detailed FE simulations for strengthened and unstrengthened steel–concrete composite beams at the sagging and hogging moment regions with and without profiled steel sheeting. The developed models were verified against experimental results from the literature. The verified models were used to present comparisons between the effect of using external post-tensioning and CFRP laminates as strengthening techniques. Applying external post-tensioning at the sagging moment regions is more effective because of the e

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Carbon Steel in Hydrochloric Acid under Dynamic Conditions
...Show More Authors

In this work, studying the effect of ethylenediamine as a corrosion inhibitor was investigated for carbon steel in aerated HCl solution in range of 0.1-1N under dynamic conditions, i.e., rotational velocity of 400–1200 rpm in the temperature range 35 – 65 ºC.  Weight loss method was employed in absence and presence of the inhibitor as an adsorption type in concentration range 1000 – 5000 ppm using rotating cylinder specimens. The experimental results showed that corrosion rate in absence and presence of inhibitor is increased with increasing temperature, rotational velocity and concentration of acid. It is decreased with increasing inhibitor concentration for the whole range of temperature, rotational velocity and concentrati

... Show More
View Publication Preview PDF