Preferred Language
Articles
/
IhfuWo4BVTCNdQwCZUSZ
Effect of non-thermal plasma by FE-DBD scheme on lipids in blood in vivo study
...Show More Authors

This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.

Scopus Crossref
View Publication
Publication Date
Mon Sep 28 2015
Journal Name
Journal Of Parasitic Diseases
The effect of toxoplasmosis on the level of some sex hormones in males blood donors in Baghdad
...Show More Authors

Toxoplasma gondii is a unique intracellular parasite, which infect a large proportion of the world population, but uncommonly causes clinically significant disease. The present study was performed to estimate the prevalence of toxoplasmosis in 400 apparently healthy blood donor males, their ages were between 18 and 57 years using enzyme linked immunosorbent assay, and to examine the effects of infection on total testosterone, free testosterone and follicle stimulating hormone (FSH) levels in their sera. Seroprevalence showed 10 (2.5 %) and 121 (30 %) of them had IgM and IgG antibodies respectively. Both acute and chronic toxoplasmosis in males recorded higher significant (P < 0.05) mean concentration for total and free testosterone hormone,

... Show More
Scopus (32)
Scopus
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources
...Show More Authors

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Alexandria Engineering Journal
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
...Show More Authors

View Publication
Scopus (23)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Sat Jul 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
In vivo histological evaluation of the effect of the topical application of estrogen hormone on wounds healing in ovariectomized rabbit
...Show More Authors

Background: Wound healing, as a normal biological process in the human body, is achieved through four precisely and highly programmed phases: hemostasis, inflammation, proliferation, and remodeling. Growth factors released in the traumatized area promote cell migration into the wound area (chemotaxis), stimulate the growth of epithelial cells and fibroblasts (mitogenesis), initiate the formulation of new blood vessels (angiogenesis), and stimulate matrix formation and remodeling of the affected region. One of factors that effects on wound healing is a sex hormones and one of these hormones is an estrogen hormone. A wide range of cutaneous cell types (eg, fibroblast, endothelial, epithelial, and inflammatory) expressed estrogen receptors, in

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Study the effect of sodium hydroxide solution on the thermal conductivity of nanocomposites
...Show More Authors

In this research, hand lay- up technique is used to prepare samples from epoxy resin reinforced with multi- walled carbon nanotubes in different weight fractions (0, 2, 3, 4, 5) wt%. The immersion effect by sodium hydroxide solution (NaOH) at normality (0.3N) for a period of (15 days) on the thermal conductivity of nanocomposites was studied, and compared to natural condition (before immersion). The thermal conductivity of epoxy nanocomposites specimens were carried out using Lee’s disk method. The experimental results showed that thermal conductivity increased with increase weight fraction before and after immersion for all specimens, while the immersion effect leads to decrease thermal conductive values compared to thermal conductivi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Study of opacity broadening in spectral lines for helium like ions in aluminum plasma which produced by laser
...Show More Authors

A theoretical analysis studied was performed to study the opacity broadening of spectral lines emitted from aluminum plasma produced by Nd-YLF laser. The plasma density was in the range 1028-1026 )) m-3 with length of plasma about ?300) m) , the opacity was studied as function of plasma density & principle quantum number. The results show that the opacity broadening increases as plasma density increases & decreases with the spacing between energy levels of emission spectral line.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
Liver Repair in Rabbits Using 532 nm Nd:YAG Laser; In Vivo Study
...Show More Authors

The main goal of this in vivo study was to evaluate the effect of 532nm Q-switched Nd: YAG Laser in combination with Human Serum Albumin 20% concentration (as a welding aid) on the liver tissue repair clinically, and histologically. The animals used in this study were 21 male rabbits divided into three main groups: control group (3 rabbits), conventionally treated group (9 rabbits) and Laser treated group (9 rabbits). Each two main groups (conventional and laser treated) consist of three sub-groups depending on the response evaluation at three different periods. The Laser group was treated using 532nm Q-switched Nd: YAG laser after adding human serum albumin immediately on the incised liver’s tissue. The energy of was 460mJ, and 4Hz fr

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of Grain Size-Secondary Electron Emission on Grain Growth in Dusty Plasma
...Show More Authors

The calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 08 2022
Journal Name
V. International Scientific Congress Of Pure, Applied And Technological Sciences
The effect of background vacuum pressure on the length of gas discharge plasma by using Aluminum electrodes
...Show More Authors

Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.

Publication Date
Fri May 06 2022
Journal Name
Razi Vaccine & Serum Research Institute
Effect of Betaine on Blood Parameters Related to the Iron Status in Acrylamide-Treated Rats
...Show More Authors

Archives of Razi Institute (ARI)

View Publication