This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.
This paper introduces a non-conventional approach with multi-dimensional random sampling to solve a cocaine abuse model with statistical probability. The mean Latin hypercube finite difference (MLHFD) method is proposed for the first time via hybrid integration of the classical numerical finite difference (FD) formula with Latin hypercube sampling (LHS) technique to create a random distribution for the model parameters which are dependent on time [Formula: see text]. The LHS technique gives advantage to MLHFD method to produce fast variation of the parameters’ values via number of multidimensional simulations (100, 1000 and 5000). The generated Latin hypercube sample which is random or non-deterministic in nature is further integ
... Show MoreBackground: Obesity is considered an important risk factor for periodontal disease. It has been reported that reactive oxygen species linking both diseases, systemic melatonin supplementation as antioxidant therapy, was addressed as an adjuvant to scaling and root surface debridement (SRP) to enhance the treatment of periodontitis. Objective: To investigate the efficacy of systemic melatonin administration in periodontitis-obese patients as an adjuvant to scaling and root surface debridement (SRP). Methods: A randomized clinical trial was conducted at a dental-specialized center. Eighty subjects were included and allocated into group-I: twenty periodontium-healthy, normal-weight people; group-II: 30 obese patients with stage-III tre
... Show MoreAbstract
The research Compared two methods for estimating fourparametersof the compound exponential Weibull - Poisson distribution which are the maximum likelihood method and the Downhill Simplex algorithm. Depending on two data cases, the first one assumed the original data (Non-polluting), while the second one assumeddata contamination. Simulation experimentswere conducted for different sample sizes and initial values of parameters and under different levels of contamination. Downhill Simplex algorithm was found to be the best method for in the estimation of the parameters, the probability function and the reliability function of the compound distribution in cases of natural and contaminateddata.
... Show More
Scorpions and spiders belong to the class Arachnida in phylum Arthropoda. Scorpions are easily distinguished by median eyes on obvious the center of the carapace and have one pair, and lateral eyes have 2-8 in some species. Scorpions do not have good eyesight so the median eyes have always been simple and they are more sensitive than the lateral pairs. They have anterior median eyes (AME) with narrow field of view and pairs of lateral eyes (LE) with more sensitivity and response to light. Family Buthidae have 2-6 lateral eyes in Compsobuthus Mesobuthus, Hottentotta, while Vaejovidae, Chactidae and Chaerilidae have 2 pairs of lateral eyes. In addition, 3 pairs are found in Orthochirus and Androctonus. Spiders have six eyes in family Pholicid
... Show MoreAn environmental study conducted on diatoms in Al Yusifiya river beyond its branching from Euphrates river. Four sites were selected along the river for the period from march 2013 to September 2013. The present study involved the measurement of physicochemical parameters, also the qualitative and quantities of diatoms. The studied parameters values ranged as follows: 19-44Cº and 16-30 Cº for air and water temperature respectively, 6.9-8.7, 595-1248 µS/cm, 6.4-8.0 mg/l for pH, electric conductivity and dissolved oxygen respectively. A total of 74 taxa were recorded for diatoms, where the pinnate diatom was the predominant and recorded 64 taxa while 10 taxa for centric diatoms. The total number of diatoms was 1197.55*104 cell /l. The tota
... Show MoreThe ceiling of the midbrain has a couple of optic lobes which are prominent and used as an optic center that reflex what it receives from eye retina fibers. The histology of optic tectum has been studied in Iraqi water snake natrix tesselata tesselata . It was found that the number of optic tectum were seven main strata organized from the outside to the inside as follows : the stratum zonula (SZ), the stratum opticum (SO), the stratum fibrosum et griseum superficialis (SFGS), the stratum griseum central (SGC), the stratum album central (SAC), the stratum griseum periventricular (SGP), and the stratum album periventricular (SAP). the three last strata consider deep layers on the optic tectum It was noticed that the thinnest strata was the fi
... Show MoreAbstract The results of isolation, morphological and microscopic diagnosis, Chromic Agar, Vitik technology and Bact Alert showed that the diagnosis of fungi isolated from blood samples of end-stage renal patients who did not undergo dialysis and those who underwent dialysis was 60 samples for each type. The total number of fungal isolates isolated from people who did not undergo dialysis was 26 pathogenic fungal isolates, with a percentage frequency of 43.33%. In this study, 4 genera of pathogenic fungi were identified: Candida spp, Rhodotorula spp, Cryptococcus spp. and Aspergillus spp. The number of Candida isolates reached 13 isolates, with a frequency of 50%. The results also showed that the diagnosed species from the genus Rhodotorula
... Show MoreThe current study presents an experimental investigation of heat transfer and flow characteristic for subcooled flow boiling of deionized water in the microchannel heat sink. The test section consisted of a single microchannel having 300μm wide nominal dimensions and 300μm height (hydraulic diameter of 300μm). The test section formed of oxygen-free copper with 72mm length and 12mm width. Experimental operation conditions spanned the heat flux (78-800) kW/m2, mass flux (1700 and 2100) kg/m2.s at 31˚C subcooled inlet temperature. The boiling heat transfer coefficient is measured and compared with existing correlations. Also, the experimental pressure drop is measured and compared with microscale p
... Show More