Preferred Language
Articles
/
Ihcrxo4BVTCNdQwCvVjB
Influence of Fiber Laser (1064 nm) on Shear Bond Strength of Titanium Abutment and Resin Cement
...Show More Authors

Introduction: The present study was performed to evaluate the influence of a 1064 nm fiber laser on shear bond strength (SBS) at the interface of titanium and resin cement. Methods: Forty titanium discs of 6 mm × 3 mm (diameter and thickness respectively) were categorized into four groups (n=10): control group without any surface treatment and three groups treated with a fiber laser with 81 ns pulse duration, 30 kHz frequency, 10000 mm/s scanning speed, 0.05 mm spot size, and different average power values (3, 5 and 7 W) depending on the tested group. Titanium disc characterization was performed by the scanning electron microscope (SEM) and surface roughness tester. Phase analysis was achieved using an X-ray diffractometer (XRD). Following these tests, resin cement application to titanium discs was performed. SBS values were determined by the universal testing machine. After debonding, the surface of titanium discs was examined by the stereomicroscope for the determination of failure modes. Data analysis was performed using analysis of variance (ANOVA) and Tukey HSD tests (α=0.05). Results: A higher surface roughness value was observed in the 7 W group followed by the 5 W and 3 W groups, and the lowest surface roughness was in the control group. Additionally, the lowest SBS value was obtained from the control group and the highest SBS value was obtained from the 7 W group followed by the 5 W and 3 W groups. Conclusion: SBS between titanium abutment and resin cement can be significantly enhanced by using a fiber laser as a surface treatment considering tested laser parameters; additionally, a positive association between surface roughness and SBS was noted in the experimental groups.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Oct 01 2023
Journal Name
Nanomedicine Research Journal
The effect of ZrO2 NPs addition on denture adaptation and diametral compressive strength of 3D printed denture base resin
...Show More Authors

Objective(s): The world of dentistry is constantly evolving, and with the advent of 3D printing technology, the possibilities are endless. However, little is known about the effects of adding ZrO2 NPs to the denture base resin of 3D additive manufacturing technique.Aim of this study is to evaluate the behavior of resin which is used to 3D printing of denture base with the addition of ZrO2 NPs on denture adaptation property and diametral compression strength.Methods: 60 samples were printed, 30 disks for diametral compressive test and 30 denture base for denture adaptation test. Three groups per test (n=10). The control group for each test included unreinforced 3Dprinted denture base resin, and the other groups were  reinforced with (2&

... Show More
View Publication
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Effect of sulfuric acid solution on thermal conductivity and impact strength of epoxy resin reinforced by silicon dioxide powder
...Show More Authors

In this search, Ep/SiO2 at (3, 6, 9, 12 %) composites is prepared by hand Lay-up method, to measure the change in the thermal conductivity and Impact Strength of epoxy resin before and after immersion in H2SO4 Solution with a 0.3N for 10 days. The results before immersion decreases with the increase of the weight ratios of the reinforcement material (SiO2), It changed from (82.6×10-2 to 38.7×10-2 W/m.°C) with change weight ratios from (3 to 12) % respectively, but after immersion time in the chemical solution where it was (65.6×10-2 W/m.°C) at the weight ratios (6 %) and became (46.6 × 10-2 W/m.°C) after immersion in sulfuric acid. The results of the Impact strength decreased by increasing the percentage weight ratio, it changed f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Evaluation of 940 nm Diode Laser in Esthetic Crown Lengthening
...Show More Authors

Abstract Background: Crown lengthening is a surgical procedure that apically positions the gingival edge and/or removes supporting bone in order to increase the amount of supra gingival tooth structure for restorative or cosmetic purposes.

The objective of the study: The purpose of this study was to evaluate the efficacy of the 940nm diode laser in esthetic crown lengthening surgery through clinical observations, patient questionnaires, clinical photographs, and gingival healing following gingival operations. Material and methods: In this randomized clinical trial, 16 patients (11 females and 5 males) had their crowns surgically lengthened using a diode laser (940 nm) in continuou

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Excision of Soft Tissue Oral Lesions by 810 nm Diode Laser
...Show More Authors

The present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 11 2006
Journal Name
Iraqi Journal Of Laser
Treatment of Bilateral Vocal Cord Paralysis by 810 nm Diode Laser
...Show More Authors

This is prospective study began in Jan. 2003 and concluded in April 2004, was undertaken to examine the benefits of 810 nm diode laser in treatment of four patient with bilateral vocal cord paralysis also to compare the results with conventional treatment Material and methods: 810 nm diode laser 15 watts was used in these cases under general anesthesia, and induction of anesthetic drug done through tracheostomy tube in all patients. All patients were decanulated “Tracheostomy tube removed”, the voice of all preserved within normal. Laser surgery in this case has more benefit and advantage than conventional methods even if the patient need more than on session of laser operation because of high success rate, less complication and easy

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Mechanical and physical properties of carbon nano tubes with kevlar fiber reinforced with polyester resin
...Show More Authors

In this research study Hardness (shore D), Water absorption,
Flexural, Impact Test, and Fracture Toughness of polymer nano
composites. The polymer nano composites based on unsaturated
polyester resin reinforced with Kevlar fibers (K.F). The samples are
attended by hand lay – up method according to (Rule mixture) for
various volume fractions of unsaturated polyester resin, fiber and
carbon nanotube. The polyester resin was matrix strengthened with
3% volume fraction from Kevlar fiber and (0.5%, 1%, 1.5%, 2%)
volume fractions of carbon nanotube. The water absorption, hardness
(shore D), flexural test, impact test and toughness fracture properties
were studied. Results showed that the water absorption increas

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a thr

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
The Influence of Alkaline Treatment of Recycled Natural Materials on the Properties of Epoxy Resin Composites
...Show More Authors

Natural fibers and particles reinforced composites are being broadly used due to their bio and specific properties such as low density and easy to machine and production with low cost. In this work, water absorption and mechanical properties such as tensile strength, flexural strength and impact strength of recycled jute fibers reinforced epoxy resin were enhanced by treating these fibers with alkaline solution. The recycled jute fibers were treated with different concentration of (NaOH) solution at (25 0C) for a period of (24) hours. From the obtained results, it was found that all these properties are improved when fibers treated with (7.5wt% NaOH) related to untreated fibers. Conversely, the mentioned properties of composit

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 14 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of smear layer on push-out bond strength to dentin of Bioceramic sealer (In vitro study)
...Show More Authors

Background: Sealers should demonstrate adhesive properties to dentin, decreasing the chance of endodontic treatment failure. Increased adhesive properties to dentin may lead to greater strength of the restored tooth, which may provide greater resistance to tooth fracture and clinical longevity of an endodontically treated tooth. The aim of this study was to evaluate the shear bond strength of Bioceramic iRoot SP sealer, AH plus sealer and Apexit plus sealer in absence or presence of smear layer using push out bond strength test. Materials and Methods: Sixty straight single roots of the mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments to achieve tapered canal walls, instrumenta

... Show More
View Publication Preview PDF