Preferred Language
Articles
/
Iha7SIcBVTCNdQwCgkKL
The Fate of the Mandibular Reconstruction Plate
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Prediction the widths of maxillary and mandibular canines and premolars from the widths of maxillary incisors and first molars (Iraqi study)
...Show More Authors

Background: This study aimed to use the combined mesio-distal crowns widths of maxillary incisors and first molars as predictors to the combined mesio-distal crowns widths of maxillary and mandibular canines and premolars. Materials and methods: The sample included 110 Iraqi Arab subjects with an age ranged between 17-25 years and class I skeletal and dental relations. The crown widths of maxillary teeth and mandibular canines and premolars were measured at the largest mesio-distal dimension on the study casts using digital electronic caliper with 0.01 mm sensitivity. Pearson’s correlation coefficient was used to determine the relation between the combined mesio-distal crowns widths of maxillary incisors and first molars and the combined

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2010
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of prophylactic Dexamethasone on postoperative swelling and trismus following impacted mandibular third molar surgical extraction
...Show More Authors

Background: Pain, swelling and trismus are the main minor complications encountered after surgical extraction of impacted third molars, minimizing these postoperative complications is the center of many studies, one proposed method is the prophylactic administration of corticosteroids, the aim of this study is to evaluate the effect of prophylactic Dexamethasone administration on facial swelling and trismus after surgical extraction of impacted third molars. Materials and methods: 20 patients were included in this study, they were randomly divided into 2 groups of 10 patients each; a study group in which patients were given 8 mg. Dexamethasone 1 hour before surgical extraction of impacted third molar and 4 mg. 6 hours postoperatively, and a

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars
...Show More Authors

Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede

View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Buckling Analysis of Edge Cracked Sandwich Plate
...Show More Authors

This work presents mainly the buckling load of sandwich plates with or without crack for different cases. The buckling loads are analyzed experimentally and numerically by using ANSYS 15. The experimental investigation was to fabricate the cracked sandwich plate from stainless steel and PVC to find mechanical properties of stainless steel and PVC such as young modulus. The buckling load for different aspect ratio, crack length, cracked location and plate without crack found. The experimental results were compared with that found from ANSYS program. Present of crack is decreased the buckling load and that depends on crack size, crack location and aspect ratio.

 

View Publication Preview PDF
Publication Date
Mon Aug 31 2020
Journal Name
Bmc Oral Health
The success of using 2% lidocaine in pain removal during extraction of mandibular premolars: a prospective clinical study
...Show More Authors
Abstract<sec><title>Background

The purpose of this study was to evaluate the anesthetic effectiveness of a buccal infiltration technique combined with local massage (using 2% lidocaine) in the extraction of mandibular premolars to be utilized as an alternative to the conventional inferior alveolar nerve block.

Methods

Patients eligible included any subject with a clinical indication for tooth extraction of the mandibular 1st or 2nd premolars. All patients were anesthetized buccally by local infiltration technique followed by an external pressure applied for 1 min directly over the injection area. In each case, another local

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 01 2012
Journal Name
Journal Of Craniofacial Surgery
Inferior Alveolar Nerve Injuries Associated With Mandibular Fractures
...Show More Authors

The study evaluates the incidence of inferior alveolar nerve injuries in mandibular fractures, the duration of their recovery, and the factors associated with them. Fifty-two patients with mandibular fractures involving the ramus, angle, and body regions were included in this study; the inferior alveolar nerve was examined for neurological deficit posttraumatically using sharp/blunt differentiation method, and during the follow-up period the progression of neural recovery was assessed. The incidence of neural injury of the inferior alveolar nerve was 42.3%, comminuted and displaced linear fractures were associated with higher incidence of inferior alveolar nerve injury and prolonged recovery time, and recovery of inferior alveolar nerve fun

... Show More
View Publication
Scopus (15)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Global NAVIGATION Satellite System Contribution for Observing the Tectonic Plate Movements: Status and Perspectives
...Show More Authors

The long-term monitoring of land movements represents the most successful application of the Global Navigation Satellite System (GNSS), particularly the Global Positioning System. However, the application of long term monitoring of land movements depends on the availability of homogenous and consistent daily position time series of stations over a period of time. Such time series can be produced very efficiently by using Precise Point Positioning and Double Difference techniques based on particular sophisticated GNSS processing softwares. Nonetheless, these rely on the availability of GNSS products which are precise satellite orbit and clock, and Earth orientation parameters. Unfortunately, several changes and modifications have been mad

... Show More
View Publication Preview PDF
Crossref