There are two main categories of force control schemes: hybrid position-force control and impedance control. However, the former does not take into account the dynamic interaction between the robot’s end effector and the environment. In contrast, impedance control includes regulation and stabilization of robot motion by creating a mathematical relationship between the interaction forces and the reference trajectories. It involves an energetic pair of a flow and an effort, instead of controlling a single position or a force. A mass-spring-damper impedance filter is generally used for safe interaction purposes. Tuning the parameters of the impedance filter is important and, if an unsuitable strategy is used, this can lead to unstable contact. Humans, however, have exceptionally effective control systems with advanced biological actuators. An individual can manipulate muscle stiffness to comply with the interaction forces. Accordingly, the parameters of the impedance filter should be time varying rather than value constant in order to match human behavior during interaction tasks. Therefore, this paper presents an overview of impedance control strategies including standard and extended control schemes. Standard controllers cover impedance and admittance architectures. Extended control schemes include admittance control with force tracking, variable impedance control, and impedance control of flexible joints. The categories of impedance control and their features and limitations are well introduced. Attention is paid to variable impedance control while considering the possible control schemes, the performance, stability, and the integration of constant compliant elements with the host robot.
The main part in hydraulic system is directional control valve. Directional control valve has complex construction such as moving spool to control the direction of actuator for required speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This study proposes the design of four ways/three position MR proportional directional control valve (4/3 MR valve). The construction of valve and the principle of work are presented. Analysis for magnetic circuit and simulation for valve performance were done. The experiment was conducted to show the principle
... Show MoreIn this paper a nonlinear adaptive control method is presented for a pH process, which is difficult to control due to the nonlinear and uncertainties. A theoretical and experimental investigation was conducted of the dynamic behavior of neutralization process in a continuous stirred tank reactor (CSTR). The process control was implemented using different control strategies, velocity form of PI control and nonlinear adaptive control. Through simulation studies it has been shown that the estimated parameters are in good agreement with the actual values and that the proposed adaptive controller has excellent tracking and regulation performance.
The research aims to prepare a report by the external auditor (Federal Office of Financial Supervision) for the control environment it is includes financial control, commitment and performance of the North Oil Company (extractive) according to the causes of pollution. The research problem it is not the Federal Office of Financial Supervision preparation a report on the things the environment include the prevent or reduction failure the administration of the causes of the pollution caused by oil mining industry by both bad planning or operational or related to efficient human resources as well as of technology to use and resulting from non-compliance local laws and instructions, as well as the inefficiency of spending on environme
... Show MoreExperimental investigations have been carried out to investigate the pH-control problems of industrial electroplating wastewater treatment plants. The accurate and sensitive PID control system could treat most problem and disturbances in the normal operation of the water treatment. However, conventional treatment was replaced by proprietary treatment agent called a QUASIL which was found to be more effective for a wide range of pH.
This study is conducted to carry out a straightforward way appropriate for quality monitoring and stability of arc stud welding process, followed by a number of procedures to control the quality of welded samples, namely torque destructive testing and visual inspection context. Those procedures were being performed to support the monitoring system and verify its validity. Thus, continuous on-line monitoring guarantees earlier discovering stud welding defects and avoiding weld repeatability. On-line welding electronic monitoring system is for non destructive determining if a just completed weld is satisfactory or unsatisfactory, depending on welding current peak value detected by the system. Also, it has been observed significant ha
... Show MoreThe research aims to identify the social control among kindergarten department students. In order to achieve the objective of the research, a sample of (400) female students: (200) from Baghdad University / Faculty of Education for women and (200) from Mustansiriyha University / Faculty of Basic Education were chosen randomly.
The researchers designed a tool to measure the social control of the study sample. It was exposed to group of specialists in the educational and psychological sciences, measurement and evaluation. In addition to specialists in kindergartens. Two indicators of validity were used. The Alpha-Cronbach method, Pearson correlation coefficient, and independent samples t-test were used to analyze the c
... Show MoreSelf control is the perception of the individual of his duty at, the capacity of self testing in systematic durations and the ability of individuate to control his behavior, The control will be spontaneous when the individual will have a special ideas about the correct or incorrect behavior and choosing his way according it.
The present study airs at:
1- building and measuring self control and balancing among means among university students according to gender and specialization.
To achieve the above mention aim, the two researchers built a scale of self control depending on some theories and applying it on a sample consists of (400) male and female students in Baghdad university studying in scientific and human fields. The two
Abstract:
the system of Administrative Control in organizations meets the need to check on the optimal use and proper resources and conservation to achieve the objectives sought by the organization, hence the system of Administrative Control is part of the overall system in any organization that has undergone evolution always to be able to keep up with progress in the development of other sciences, and that the growth of coherence between subordinates in the organization means the ability to influence the opinions, ideas and attitudes to change it for directions the organization and its values and this is reflected positively on the coherence of the organization, the researcher interest of the imp
The research aims to: Preparing rehabilitative exercises with accompanying tools to rehabilitate those with shoulder dislocation. Knowing the effect of rehabilitative exercises and accompanying aids in improving the muscular strength and motor range of those with dislocations in the shoulder joint. The two researchers used the experimental design with the same experimental group with the pre and post tests, so the researcher chose a sample appropriate to the nature of his research problem, its goals and its hypotheses, as a sample of the injured was chosen to remove the shoulder joint, who completed the treatment, who were not practicing sports, and those who went to the Physiotherapy Center at Al-Was
... Show More