Purpose: To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design: Descriptive observational. Place and Duration of Study: Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods: A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results: Mean age was 28.54 ± 6.6 years, mean spherical equivalent of refraction was -3.57 ± 3.35 D. Mean CCT by Optovue, and Sirius were534.13 ± 27.88 μm, and 540.2 ± 27.85μm, respectively.Mean CCT differences between them were -6.070± 6.593 μm, (p < 0.05). Minimum thickness by Optovue was 526.79 ± 27.81, and by Sirius was 537.44 ± 27.56, mean difference between the two devices was 10.66 ± 6.89,p= 0.00. The net power by OCT was 43.44 ± 1.456, mean K by Sirius was 43.597 ± 1.408, with p=0.000. Maximum level of agreement between the two devices is -18.99 to 6.85 for CCT, is widest for minimum thickness -24.166 to 2.85 and narrowest for differences between net corneal power by OCT and mean K By Sirius is -0.87 to 1.18. Conclusion: In clinical practice, the two devices cannot be used interchangeably. CCT and keratometry should be evaluated and followed up using the same device.
Schmidt Cassegrain spider obscuration telescope (SCT) is one of the types of observations operating with a concave mirror. It combines several lenses and mirrors working together as an optical system. The light rays fall into the tube from the main mirror and gather on another smaller mirror called a secondary mirror. Unlike the formation of Newton's telescope, no light is made from the secondary mirror out the side of the tube but is directed to the middle of the main mirror. There is an opening in the middle of the main mirror so the light beam can go out and direct the vision lens system. The secondary mirror is located in the middle of a glass slice and is installed by thin carriers. The function of this board is to correct the portr
... Show MoreIn this paper a refractive index sensor based on micro-structured optical fiber has been proposed using Finite Element Method (FEM). The designed fiber has a hexagonal cladding structure with six air holes rings running around its solid core. The air holes of fiber has been infiltrated with different liquids such as water , ethanol, methanol, and toluene then sensor characteristics like ; effective refractive index , confinement loss, beam profile of the fundamental mode, and sensor resolution are investigated by employing the FEM. This designed sensor characterized by its low confinement loss and high resolution so a small change in the analyte refractive index could be detect which is could be useful to detect the change of
... Show MoreNanostructure of chromium oxide (Cr2O3-NPs) with rhombohedral structure were successfully prepared by spray pyrolysis technique using Aqueous solution of Chromium (III) chloride CrCl3 as solution. The films were deposited on glass substrates heated to 450°C using X-ray diffraction (XRD) shows the nature of polycrystalline samples. The calculated lattice constant value for the grown Cr2O3 nanostructures is a = b = 4.959 Å & c = 13.594 Å and the average crystallize size (46.3-55.6) nm calculated from diffraction peaks, Spectral analysis revealed FTIR peak characteristic vibrations of Cr-O Extended and Two sharp peaks present at 630 and 578 cm-1 attributed to Cr-O “stretching
... Show MoreFive hundred nasal swabs were taken from normal medical staff and public in the city of Baghdad. Several identification parameters were used to recognize the bacterial isolates. S. aureus isolations form nasal swabs were identified using morphology and VITECK 2 system. Polymerase chain reaction (PCR) was employed to determine PVL (Panton–Valentine leukocidin ) gene in S. aureus. The data showed no significant evidence on the relationship between PVL gene presence and gender and age of the studied groups. There was no relation between the prevalence of PVL gene in the age groups of 21-30 years (p=0.328) and 31-40 years (p=0.682).
The results showed that 38.4% and 37.5% S. aureus isolate
... Show MoreBackground: The styloid process is a cylindrical bone (protrusion). It situated above the common carotid artery between the external and internal branches immediately proximal to the internal jugular vein and facial nerves. The styloid process varies in length also it may be absent as well as elongated. Classically, an elongated styloid process and calcified of stylohyoid ligament causes Eagle’s syndrome. The aim of this study was to examine the styloid process using 3 dimensional multi-detector computed tomography (3D-MDCT) to detect the presence of Eagle’s syndrome that causes severe headache and migraine. Materials and methods: One hundred patients with severe headache and migraine were exposed to 3D- multi-detector CT with special
... Show MoreAnalysis and determination of some of the elastic moduli and other geotechnical parameters in the campus of the University of Baghdad performed by using New Sonic Viewer in the field to measure (Vp) and (Vs) velocities as well as the density of the upper soil inside the campus. Seventeen profiles were selected each of (10) m. length distributed randomly inside the university campus to evaluate the top soil properties in addition to the soil profile.
The ultrasonic waves showed two layers of the soil with different velocities of
(Vp) and (Vs). The velocities of p-wave of the first layer ranged from (288-642) m/sec. On other hand the velocities of shear wave (Vs) in the same layer ranged from (88-193) m/sec. In the second layer the v
DC glow discharges were generated between a thin cylindrical anode and a flat cathode, streamers are thought to propagate by photo-ionization; the parameters of photo-ionization depend on the He: CO ratio. Therefore we study streamers in He ( 90%, 80% and 70% ) with (10%, 20% and 30%) CO respectively. The streamer diameter is essentially the change by increase for similar voltage and pressure in all He-CO mixtures.
Hepatitis-B (HBV) is a viral disease cause liver damage, cirrhosis, fibrosis and hepatocellular carcinoma. Present study attempted to elucidate the biochemical and haematological markers other than Australia antigen, of hepatitis,B,vairusV (HBsAg) for better assessment of HBV infection. The present study was conducted on 76 men, 50 of them were found to be HBeAg positive and 26 were negative, mean age was53±5.7years. Haematological parameters such as Absolute Erythrocyte( Abs Eryt), Absolute Leukocyte(Abs Leuk) , Haemoglobin(Hb), Packed Cell Volume(PCV),Mean Corpuscular Volume (MCV), Red Cell Distribution Width (RDW), Mean Corpuscular Haemoglobin (MCH),MCH Concentration(MCHC) ,Neutrophi
... Show MoreIn this research, we built a program to assess Weibull parameters and wind power of three separate locations in Iraq: Baghdad, Basrah and Dhi-qar for two years 2009 and 2010, after collecting and setting the data available from the website "Weather Under Ground" for each of the stations Baghdad, Basrah and Dhi-qar. Weibull parameters (shape parameter and scale parameter) were estimated using maximum likelihood estimation method (MLE) and least squares method (LSM). Also, the annual wind speed frequencies were calculated noting speed most readily available through the above two years. Then, we plotted Weibull distribution function and calculate the most significant quantities represented by mean wind speed, standard deviation of the value
... Show MoreDoppler broadening technique is suggested to monitor the development of tumours. It depends on the sensitivity of positronium (Ps) annihilation parameters to the sub- microstructural changes in biological tissues. This technique uses high resolution HpGe detector to measure the lineshape parameters (S and W) in normal mice's mammary tissues and adenocarcinoma mammary tissues as a function of tumour growth. The results demonstrate that the central parameter (S) decreases and the wing parameter (W) increases as the tumour grow. It is found that the S parameter changes considerably with the distribution of voids which are affected by the tumour development. Therefore the present technique can successfully be employed to monitor the developm
... Show More