Preferred Language
Articles
/
IhY2s4sBVTCNdQwClNct
Corneal Parameters Measurement in Healthy Subjects Using Scheimpflug and Anterior Segment Optical Coherence Tomography
...Show More Authors

Purpose:  To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design:  Descriptive observational. Place and Duration of Study:  Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods:  A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results:  Mean age was 28.54 ± 6.6 years, mean spherical equivalent of refraction was -3.57 ± 3.35 D. Mean CCT by Optovue, and Sirius were534.13 ± 27.88 μm, and 540.2 ± 27.85μm, respectively.Mean CCT differences between them were -6.070± 6.593 μm, (p < 0.05). Minimum thickness by Optovue was 526.79 ± 27.81, and by Sirius was 537.44 ± 27.56, mean difference between the two devices was 10.66 ± 6.89,p= 0.00. The net power by OCT was 43.44 ± 1.456, mean K by Sirius was 43.597 ± 1.408, with p=0.000. Maximum level of agreement between the two devices is -18.99 to 6.85 for CCT, is widest for minimum thickness -24.166 to 2.85 and narrowest for differences between net corneal power by OCT and mean K By Sirius is -0.87 to 1.18. Conclusion:  In clinical practice, the two devices cannot be used interchangeably. CCT and keratometry should be evaluated and followed up using the same device.

Scopus Crossref
View Publication
Publication Date
Tue Dec 30 2014
Journal Name
International Journal Of Medicine And Pharmaceutical Sciences (ijmps)
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Measurement of the distance to the central stars of Nebulae by using Expansion methods with Alladin Sky Atlas
...Show More Authors
Abstract<p>The usual methods of distance determination in Astronomy parallax and Spectroscopic with Expansion Methods are seldom applicable to Nebulae. In this work determination of the distances to individual Nebulae are calculated and discussed. The distances of Nebulae to the Earth are calculated. The accuracy of the distance is tested by using Aladin sky Atlas, and comparing Nebulae properties were derived from these distance made with statistical distance determination. The results showed that angular Expansions may occur in a part of the nebulae that is moving at a velocity different than the observed velocity. Also the results of the comparison of our spectroscopic distances with the trig</p> ... Show More
View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 24 2020
Journal Name
Basic Education College Magazine For Educational And Humanities Sciences
The healthy behavior of the Arab citizen in light of the Corona crisis 2020-6-24
...Show More Authors

Abstract: The world witnessed the speed of a dangereuse virus now as Corona or Covid 19, which left many deaths in light of the inability of local and international Heath agencies to find a suitable vaccine to eliminate it and limit its spread, which negatively affected humain life in its various fields, and remains adopting healthy behaviors and habits A healthy Heath is the best solution to face the spread of the epidemic until realistic solutions that eliminate the virus are found.

Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Prediction of Process Parameters That Affecting on Surface Roughness in Multi-Point Forming Process Using ANOVA Algorithm
...Show More Authors

 

Multipoint forming process is an engineering concept which means that the working surface of the punch and die is produced as hemispherical ends of individual active elements (called pins), where each pin can be independently, vertically displaced using a geometrically reconfigurable die. Several different products can be made without changing tools saved precious production time. Also, the manufacturing of very expensive rigid dies is reduced, and a lot of expenses are saved. But the most important aspects of using such types of equipment are the flexibility of the tooling. This paper presents an experimental investigation of the effect of three main parameters which are blank holder, rubber thickness and forming speed th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 03 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Variation of Charging Parameters on A dust Grain in Laboratory Plasma by Using Orbital-Motion Limited Theory
...Show More Authors

       Using orbit- motion limited theory, as the exact theory in calculating the ion and electron current in dusty plasma, the variations of charge number on a dust grain in Ar-plasma are studied by changing various charging parameters. Most of dependences of charge number on plasma parameters in this paper take into account the close packed effect.

View Publication Preview PDF
Publication Date
Wed Jun 18 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Cone Beam Computed Tomography in an Evaluation and Diagnosis of Anatomical Variations and Pathological Lesions in Maxillary Sinus Prior to Maxillary Sinus Lift Surgery
...Show More Authors

Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner re

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Compressive strength measurement for cement replacement with recycled glass in concrete
...Show More Authors

The most important environmental constraints at the present time
is the accumulation of glass waste (transparent glass bottles). A lot of
experiments and research have been made on waste and recycling
glass to get use it as much as possible. This research using recycling
of locally waste colorless glass to turn them into raw materials as
alternative of certain percentages of cement to save the environment
from glass waste and reduce some of the disadvantages of cement
with conserving the mechanical and physical properties of concrete
made. A set of required samples were prepared for mechanical test
with different weight percentage of waste glass (2%, 4%, 5%, 6%,
8%, 10%, 15%, 20% and 25%). American standard

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
A giant A4-A5 distal anterior cerebral artery aneurysm treated with microsurgical clip reconstruction
...Show More Authors

Background. Aneurysms of the distal anterior cerebral artery (DACA) are uncommon; they often form near the pericallosal-callosomarginal junction and are typically small. To our knowledge, giant DACA aneurysms developing from the more distant parts of the anterior cerebral artery (ACA), A4-5, have been described only once in the literature. Case description. A 66-year-old gentleman reported with a brief loss of consciousness followed by weakness in his right lower leg. The patient was admitted with a Glasgow Coma Score (GCS) of 15. A computed tomography (CT) scan of the head revealed a left hyperdense mass in the frontal parasagittal supracallosal region. Contrast MRI revealed a heterogeneously enhancing mass measuring 35x30x25 mm. C

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref
Publication Date
Fri Oct 20 2023
Journal Name
Bmc Endocrine Disorders
Dietary caffeine intake is associated with favorable metabolic profile among apparently healthy overweight and obese individuals
...Show More Authors
Abstract<sec> <title>Background

Recent studies have revealed some conflicting results about the health effects of caffeine. These studies are inconsistent in terms of design and population and source of consumed caffeine. In the current study, we aimed to evaluate the possible health effects of dietary caffeine intake among overweight and obese individuals.

Methods

In this cross-sectional study, 488 apparently healthy individuals with overweight and obesity were participated. Dietary intake was assessed by a Food Frequency Questionnaire (FFQ) and

... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref