The current study aims to investigate the relationship between lipid peroxidation, represented by seminal malondialdehyde (MDA) level, and integrity of sperm plasma membrane, represented by the hypo-osmotic swelling (HOS) test score, in infertile men. One hundred and twenty Iraqi men (20 fertile and 100 infertile) shared in this study during their attendance to the High Institute for Infertility Diagnosis and Assisted Reproductive Technologies/Al- Nahrain University. The mean age of the fertile men was (30.46±0.78) years while the mean age of infertile men was (32.58±0.64) years with the duration of infertility (5.36±0.33) years. Semen samples were collected and the parameters of seminal fluid analysis were assessed; also, the HOS test score and seminal MDA level were determined. The results showed a significant (P<0.05) decrease in sperm concentration, sperm motility, sperm grade activity (progressive sperm motility and non-progressive sperm motility), total progressive sperm and normal sperm morphology with a significant (P<0.05) increase in sperm agglutination and round cells count in the infertile group compared with the fertile group. The percentage of sperm HOS test score in the infertile men was significantly (P<0.05) lower than that in the fertile men while seminal MDA level in the infertile men was significantly (P<0.05) higher than in the fertile men. Also, the results revealed a significant negative correlation (r = -0.48, P<0.05) between HOS test score and seminal MDA level in the infertile men. In conclusion, increased seminal MDA levels together with poor response of spermatozoa to hypo-osmotic stress in infertile men could represent the pathological impact of lipid peroxidation on the spermatozoa membrane and consequently on sperm function and quality. Lipid peroxidation may alter sperm membrane functional intergrity adversely and contribute to abnormal sperm function.
Fire incidences are classed as catastrophic events, which mean that persons may experience mental distress and trauma. The development of a robotic vehicle specifically designed for fire extinguishing purposes has significant implications, as it not only addresses the issue of fire but also aims to safeguard human lives and minimize the extent of damage caused by indoor fire occurrences. The primary goal of the AFRC is to undergo a metamorphosis, allowing it to operate autonomously as a specialized support vehicle designed exclusively for the task of identifying and extinguishing fires. Researchers have undertaken the tasks of constructing an autonomous vehicle with robotic capabilities, devising a universal algorithm to be employed
... Show MoreThe simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was
... Show MoreThis article introduces a novel procedure to detect an approximate solution to Fredholm fractional integro-differential equations with linear type (LFFIDE) defined using Caputo fractional derivative. The new procedure approximates the solution using three types of polynomials: Laguerre polynomials, Hermite polynomials, and Legendre polynomials, thereafter transforming the problem into a linear programming problem. The approximate solutions are compared using testing examples to examine the efficiency of the suggested approach. Also, a comparison with the other methods using the same polynomials illustrates The effectiveness and consistency of the proposed technique. Finally, the error analysis of the proposed technique and convergent are di
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show MoreThe current paper examines the Arab EFL teacher view on the application of AI-based chatbots as a method of aiding writing instruction. It explores pedagogy, didactic difficulties and ethics. The overall aim is to clarify the perception that teachers have of AI chatbots as a useful tool in the writing process and to find out to what degree these perceptions are reflected in instructional decision-making and classroom behaviors. A quantitative study was conducted using a structured questionnaire that was given to forty Arab EFL teachers, using a sequential explanatory mixed-method design. To elaborate and contextualize the survey results, qualitative enquiry was implemented through semi-structured interviews with twelve teachers. Fin
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreCommercial, industrial, and military activity, largely in the 19th and 20th centuries, have led to environmental pollution that can threaten human health and ecosystem function, liquid gas petroleum (LPG) products are the major sources of energy for industry and daily life that cause environmental contamination during various stages of production, transportation, refining and use. Screening of bacterial isolate by using clear zone techniques and biomass and optical density. Results revealed that isolate Burkholdaria cepatia showed a high ability for hydrocarbons biodegradation and this isolate identified depending on morphological cultural, gram stain, microscopic features, biochemical tests, and VITEK2 compact. In this study,
... Show More