Preferred Language
Articles
/
IRcSW5MBVTCNdQwC39IX
Cord Blood Sex Hormones Concentration: Relation to Birth Weight and Pregnancy Complications

Objectives: Umbilical cord blood can be taken at birth and largely gives indication of fetal and maternal conditions. The aim of the study was to investigate the relation between sex hormones in cord blood and birth weight of newborns and pregnancy complications. Methods: Fifty cord blood samples were collected from newborns at labor room of Baghdad Teaching Hospital between May and October 2018. Blood was withdrawn from their mothers for lead analysis. Five milliliters (ml) of cord blood was taken, 3 ml was used for testosterone and estradiol analysis (using enzyme-linked immunosorbent assay) and 2 ml for lead measurement by lead care analyzer. Newborns weight and head circumference were measured. Delivered women were divided into four groups: Women with normal pregnancy, women with pre-eclampsia, diabetic women and polycystic ovary syndrome (PCOS) women. Results: There was no significant difference in age between women in all groups (P > 0.05). Birth weights, estradiol, and testosterone were significantly different between groups. Estradiol was higher in cord blood of newborns of PCOS women (P < 0.05) than others. Testosterone was higher in cord blood of babies of PCOS and pre-eclampsia women compared with those of diabetes (P < 0.05). There were no significant differences between male and female neonates regarding cord estradiol (3596.27 ± 1934.69, 3714.57 ± 1581.47 pg/ml respectively), and testosterone (393.18 ± 87.14, 361.43 ± 102.14 ng/ml respectively) (P > 0.05). Maternal lead levels correlated positively with cord lead (r = 0.905, P < 0.05), which correlated negatively with head circumference (r = −0.766, P < 0.05). Birth weight correlated negatively with estradiol (r = −0.295), but positively with testosterone (r = 0.006) (P > 0.05). Conclusion: Cord blood estradiol and testosterone levels do not differ between males and females. Estradiol was high in cord blood of PCOS mothers. Testosterone was high in cord blood of PCOS and pre-eclampsia mothers. The increase in cord lead causes decrease in babies head circumference.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 01 2016
Journal Name
European Academic Research
Double Victimization for Black Woman in Susan Lori Parks In the Blood

BMMAM Saleh, EUROPEAN ACADEMIC RESEARCH, 2016

View Publication
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement Of Organic Concentration in Aldehydes By The Derivative Neutron Activation Analysis Technique

The aim of this paper is determine the concentration of the organic oxygen in some organic compounds (Aldehydes ) by the derivative neutron activation analysis technique, and the derivative of the oxygen by the nitrogen equivalent toit and the irradiation of anew sample in flounce (1.73*106  n.cm-2.s-1) by the neutron generator .Then the calculation of the radioactivity which is done by using NaI(Tl) . After that we determine the concentration of nitrogen by calibration curve that includes nitrogen compounds which have apparent chemical and physical characteristics .For comparison the result is done by using keldal method.           

View Publication Preview PDF
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Acetic acid concentration estimation using plastic optical fiber sensor based surface Plasmon resonance

Optical fiber chemical sensor based surface Plasmon resonance for sensing and measuring the refractive index and concentration for Acetic acid is designed and implemented during this work. Optical grade plastic optical fibers with a diameter of 1000μm were used with a diameter core of 980μm and a cladding of 20μm, where the sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal and the Acetic acid is placed on the sensing probe.

Crossref (8)
Crossref
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
The Effect of the Concentration of Colloidal Silver Nanoparticles on Optical Limiting Reliability

The effect of the concentration of the colloidal nanomaterial on their optical limiting behavior is reported in this paper. The colloids of sliver nanoparticles in deionized water were chemically prepared for the two concentrations (31 ppm and 11ppm). Two cw lasers (473 nm Blue DPSS laser and 532 nm Nd:YAG laser) are used to compare the optical limiting performance for the samples. UV–visible spectrophotometer, transmission electron microscope (TEM) and Fourier Transformation Infrared Spectrometer (FTIR) were used to obtain the characteristics of the sample. The nonlinear refractive index was calculated to be in the order of 10-9 cm2/W. The results demonstrate that the observed limiting response is significant for 532nm. In addition, t

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
The Effect of Chlorine Concentration on the Optical Constants of SnS Thin Films

Chlorine doped SnS have been prepared utilizing chemical spray pyrolysis. The effects of chlorine concentration on the optical constants were studied. It was seen that the transmittance decreased with doping, while reflectance, refractive index, extinction coefficient, real and imaginary parts of dielectric constant were increased as the doping percentage increased. The results show also that the skin depth decrease as the chlorine percentage increased which could be assure that it is transmittance related.

Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
The Influence of CeO2 Concentration on Some Physical Properties of Y2O3 Thin Films

       Thin films of pure yttrium oxide (Y2O3) and doped with cerium oxide (CeO2) were prepared by the chemical spray pyrolysis(CSP)method. The structural, optical and electrical properties of the prepared films were investigated. The analysis of X-ray diffraction (XRD) thin films revealed that the undoped and doped Y2O3  were amorphous with a broad hump around 27o and narrow humps around 48o and 62o for all samples. Except for the Y2O3:6wt.%CeO2 thin film, all had signal preferential orientation along the (100) plane at 2θ=12.71o which belongs to CeO2, Field emission scanning electron mic

... Show More
Scopus (6)
Crossref (3)
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Effect of the Concentration of Copper on the Properties of Copper Sulfide Nanostructure

Nanoparticles of copper sulfide have been prepared by simple reaction between using copper nitrate with different concentrations ratio 0.1, 0.3, and 0.5 mM, thiourea by a simple chemical route. The prepared Nano powders have been deposited onto glass substrates by casting method at 60°C. The structure of the product Nano- films has been studied by x-ray diffraction, where the patterns showed that all the samples have a hexagonal structure of covellite copper sulfide with the average crystalline sizes 14.07- 16.51 nm. The morphology has been examined by atomic force microscopy, and field emission scan electron microscopy. The AFM images showed particles with almost spherical and rod shapes with average diameter sizes of 49.11- 90.64 nm.

... Show More
Scopus (8)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of Uranium Concentration in Sheep Organs for Some Iraqi&#1765;s Cities

The aim of this research is to determine the uranium concentration and its distribution in many sheep organs that live in different region of Iraq. The uranium concentration in tissue samples is measured by using fission tracks registration in CR-39 detector that caused by the bombardment of U235 with thermal neutrons from (241Am-Be) neutron source of thermal flux (5x 103 n.cm-2. s-1). The results show that the maximum uranium concentration in bronchiole tissues of the animals was found in Karbala city (3.706ppm) while the minimum concentration (0.127 ppm) was found in Al-Faluja city, also the same result in lung tissue the maximum value was found in Karbala city (2.313ppm) and the minimum concentration in Al Fluja (0.082). Otherwise,

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Evaluation of Uranium Concentration and Calculated Doses of Radiation Resulting From the Tap and Bottled Drinking Water in Babylon - middle Iraq

      In this study, uranium concentrations were evaluated and the annual effective dose was calculated from the consumption of bottled water and tap water used for drinking in Babylon, middle Iraq. Uranium isotopes (238U, 234U, 235U) were determined for all samples collected using the phosphorylation analyzer technique represented device (KPA). Forty-four samples were collected to cover almost all districts and regions of Babylon.  Thirty tap water samples were collected from residential neighborhoods, with 14 samples from local brand bottled water. The results show that the uranium concentrations in the tap water samples ranged from 1.66 μg.L-1 to 2.64 μg.L-1, with an avera

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Study the electronic and spectroscopic properties of ALxB7-XN7 Wurtzoids as a function of size and concentration using density functional theory

Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
View Publication