Objectives: Umbilical cord blood can be taken at birth and largely gives indication of fetal and maternal conditions. The aim of the study was to investigate the relation between sex hormones in cord blood and birth weight of newborns and pregnancy complications. Methods: Fifty cord blood samples were collected from newborns at labor room of Baghdad Teaching Hospital between May and October 2018. Blood was withdrawn from their mothers for lead analysis. Five milliliters (ml) of cord blood was taken, 3 ml was used for testosterone and estradiol analysis (using enzyme-linked immunosorbent assay) and 2 ml for lead measurement by lead care analyzer. Newborns weight and head circumference were measured. Delivered women were divided into four groups: Women with normal pregnancy, women with pre-eclampsia, diabetic women and polycystic ovary syndrome (PCOS) women. Results: There was no significant difference in age between women in all groups (P > 0.05). Birth weights, estradiol, and testosterone were significantly different between groups. Estradiol was higher in cord blood of newborns of PCOS women (P < 0.05) than others. Testosterone was higher in cord blood of babies of PCOS and pre-eclampsia women compared with those of diabetes (P < 0.05). There were no significant differences between male and female neonates regarding cord estradiol (3596.27 ± 1934.69, 3714.57 ± 1581.47 pg/ml respectively), and testosterone (393.18 ± 87.14, 361.43 ± 102.14 ng/ml respectively) (P > 0.05). Maternal lead levels correlated positively with cord lead (r = 0.905, P < 0.05), which correlated negatively with head circumference (r = −0.766, P < 0.05). Birth weight correlated negatively with estradiol (r = −0.295), but positively with testosterone (r = 0.006) (P > 0.05). Conclusion: Cord blood estradiol and testosterone levels do not differ between males and females. Estradiol was high in cord blood of PCOS mothers. Testosterone was high in cord blood of PCOS and pre-eclampsia mothers. The increase in cord lead causes decrease in babies head circumference.
Endometriosis is a common women health disorder that occurs when Endometrial-like tissue grows outside the uterus. This may lead to irregular bleeding , pelvic pain, infertility and other complications. Metformin, because of its activity to improve insulin sensitivity, it is used for the treatment of diabetes; it also has a modulatory effect on ovarian steroid production and has anti-inflammatory properties, all may suggest its possible effect in treatment of endometriosis. This study was planned to determine the effect of metformin on serum levels of&nbs
... Show MoreThis paper proposes and tests a computerized approach for constructing a 3D model of blood vessels from angiogram images. The approach is divided into two steps, image features extraction and solid model formation. In the first step, image morphological operations and post-processing techniques are used for extracting geometrical entities from the angiogram image. These entities are the middle curve and outer edges of the blood vessel, which are then passed to a computer-aided graphical system for the second phase of processing. The system has embedded programming capabilities and pre-programmed libraries for automating a sequence of events that are exploited to create a solid model of the blood vessel. The gradient of the middle c
... Show MoreThe study aimed to investigate the effect of fungicides chlorothalonil at different concentrations ( 0.1 , 0.5 , 5 , 25 , 50 ) × 10 - 5 M on some cytogenetic parameters of human peripheral blood lymphocytes . The genotoxicity parameters were estimated by the number of chromosomal aberrations (CAs) and their types and by estimating the induced micronuclei (Mn) . Cytotoxic effect recorded by estimating the mitotic index (MI) . Results revealed that the fungicide increased the CAs in dose – response pattern with positive correlation coefficient ( r = + 0.964) , there was a significant differences among the concentrations (P<0.01) . The major CAs records chromosomal breakage at concentrations. 0.5 , 5 , 25 , and 50 , while the lowest concen
... Show MoreBackground: Age progression is regarded as a critical risk factor in morbidity and mortality because of a weakened immune system. Although various studies have dealt with electrolyte imbalance in COVID-19 patients, the outcomes of these studies were partially understood. Objective: The current study aims to determine some biochemical parameters in old Iraqi COVID-19 patients and highlight the outcomes according to the aging role in the development of COVID-19 by suggesting new mechanisms. Materials and methods: forty COVID-19 patients were enrolled in the current study and divided into two groups: Gm includes (20) men, and Gf includes (20) women. The parameters (Na+, K+, Cl-, LDH, and Hb ) were determined in sera of patients and c
... Show MoreBMMAM Saleh, EUROPEAN ACADEMIC RESEARCH, 2016
The effect of the concentration of the colloidal nanomaterial on their optical limiting behavior is reported in this paper. The colloids of sliver nanoparticles in deionized water were chemically prepared for the two concentrations (31 ppm and 11ppm). Two cw lasers (473 nm Blue DPSS laser and 532 nm Nd:YAG laser) are used to compare the optical limiting performance for the samples. UV–visible spectrophotometer, transmission electron microscope (TEM) and Fourier Transformation Infrared Spectrometer (FTIR) were used to obtain the characteristics of the sample. The nonlinear refractive index was calculated to be in the order of 10-9 cm2/W. The results demonstrate that the observed limiting response is significant for 532nm. In addition, t
... Show MoreThe aim of this research is to determine the uranium concentration and its distribution in many sheep organs that live in different region of Iraq. The uranium concentration in tissue samples is measured by using fission tracks registration in CR-39 detector that caused by the bombardment of U235 with thermal neutrons from (241Am-Be) neutron source of thermal flux (5x 103 n.cm-2. s-1). The results show that the maximum uranium concentration in bronchiole tissues of the animals was found in Karbala city (3.706ppm) while the minimum concentration (0.127 ppm) was found in Al-Faluja city, also the same result in lung tissue the maximum value was found in Karbala city (2.313ppm) and the minimum concentration in Al Fluja (0.082). Otherwise,
... Show MorePolyaniline nanofibers (PAni-NFs) have been synthesized under various concentrations (0.12, 0.16, and 0.2 g/l) of aniline and different times (2h and 3 h) by hydrothermal method at 90°C. Was conducted with the use of X-ray diffraction (XRD), Fourier Transform Infrared spectra (FTIR), Ultraviolet-Visible (UV-VIS) absorption spectra, Thermogravimetric Analysis (TGA), and Field Emission-Scanning Electron Microscopy (FE-SEM). The X-ray diffraction patterns revealed the amorphous nature of all the produced samples. FE-SEM demonstrated that Polyaniline has a nanofiber-like structure. The observed typical peaks of PAni were (1580, 1300-1240, and 821 cm-1 ), analyzed by the chemical bonding of the formed PAni through FTIR spectroscopy. Also, tests
... Show MoreNanoparticles of copper sulfide have been prepared by simple reaction between using copper nitrate with different concentrations ratio 0.1, 0.3, and 0.5 mM, thiourea by a simple chemical route. The prepared Nano powders have been deposited onto glass substrates by casting method at 60°C. The structure of the product Nano- films has been studied by x-ray diffraction, where the patterns showed that all the samples have a hexagonal structure of covellite copper sulfide with the average crystalline sizes 14.07- 16.51 nm. The morphology has been examined by atomic force microscopy, and field emission scan electron microscopy. The AFM images showed particles with almost spherical and rod shapes with average diameter sizes of 49.11- 90.64 nm.
... Show MoreOptical fiber chemical sensor based surface Plasmon resonance for sensing and measuring the refractive index and concentration for Acetic acid is designed and implemented during this work. Optical grade plastic optical fibers with a diameter of 1000μm were used with a diameter core of 980μm and a cladding of 20μm, where the sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal and the Acetic acid is placed on the sensing probe.