Objectives: Umbilical cord blood can be taken at birth and largely gives indication of fetal and maternal conditions. The aim of the study was to investigate the relation between sex hormones in cord blood and birth weight of newborns and pregnancy complications. Methods: Fifty cord blood samples were collected from newborns at labor room of Baghdad Teaching Hospital between May and October 2018. Blood was withdrawn from their mothers for lead analysis. Five milliliters (ml) of cord blood was taken, 3 ml was used for testosterone and estradiol analysis (using enzyme-linked immunosorbent assay) and 2 ml for lead measurement by lead care analyzer. Newborns weight and head circumference were measured. Delivered women were divided into four groups: Women with normal pregnancy, women with pre-eclampsia, diabetic women and polycystic ovary syndrome (PCOS) women. Results: There was no significant difference in age between women in all groups (P > 0.05). Birth weights, estradiol, and testosterone were significantly different between groups. Estradiol was higher in cord blood of newborns of PCOS women (P < 0.05) than others. Testosterone was higher in cord blood of babies of PCOS and pre-eclampsia women compared with those of diabetes (P < 0.05). There were no significant differences between male and female neonates regarding cord estradiol (3596.27 ± 1934.69, 3714.57 ± 1581.47 pg/ml respectively), and testosterone (393.18 ± 87.14, 361.43 ± 102.14 ng/ml respectively) (P > 0.05). Maternal lead levels correlated positively with cord lead (r = 0.905, P < 0.05), which correlated negatively with head circumference (r = −0.766, P < 0.05). Birth weight correlated negatively with estradiol (r = −0.295), but positively with testosterone (r = 0.006) (P > 0.05). Conclusion: Cord blood estradiol and testosterone levels do not differ between males and females. Estradiol was high in cord blood of PCOS mothers. Testosterone was high in cord blood of PCOS and pre-eclampsia mothers. The increase in cord lead causes decrease in babies head circumference.
Applying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti
... Show MoreOlanzapine (OLZ) is classified as a typical antipsychotic drug utilized for the treatment of schizophrenia. Its oral bioavailability is 60% due to its low solubility and pre-systemic metabolism. Hence, the present work aims to formulate and evaluate OLZ nanoparticles dissolving microneedles (MNs) for transdermal delivery to overcome the problems associated with drug administration orally. OLZ nanoparticles were prepared by the nanoprecipitation method. The optimized OLZ nanoparticle formula was utilized for the fabrication of dissolving MNs by loading OLZ nanodispersion into polydimethylsiloxane (PDMS) micromould cavities, followed by casting the polymeric solution of polyvinylpyrrolidone(PVP-K30) and polyvinyl alcohol (PVA) to form
... Show MoreIn this paper, a compartmental differential epidemic model of COVID-19 pandemic transmission is constructed and analyzed that accounts for the effects of media coverage. The model can be categorized into eight distinct divisions: susceptible individuals, exposed individuals, quarantine class, infected individuals, isolated class, infectious material in the environment, media coverage, and recovered individuals. The qualitative analysis of the model indicates that the disease-free equilibrium point is asymptotically stable when the basic reproduction number R0 is less than one. Conversely, the endemic equilibrium is globally asymptotically stable when R0 is bigger than one. In addition, a sensitivity analysis is conducted to determine which
... Show MoreDental clinicians and professionals need an affordable, nontoxic, and effective disinfectant against infectious microorganisms when dealing with the contaminated dental impressions. This study evaluated the efficiency of hypochlorous acid (HOCl) as an antimicrobial disinfectant by spraying technique for the alginate impression materials, compared with sodium hypochlorite, and its effect on dimensional stability and reproduction of details. HOCl with a concentration of 200 ppm for 5 and 10 min was compared with the control group (no treatment) as a negative control and with sodium hypochlorite (% 0.5) as a positive control. Candida albicans, Staphylococcus aureus, and Pseudomonas aeruginosa were selected to assess the antimicrobi
... Show More