Literary translation is one of the most difficult types of translation ,because it conveys feelings that differ from one person to another, and since the language constitutes an obstacle to understanding the Andalusian excerpts, the translators resorted to translating it, and this was a second start to the text, different from its first start, is said from the tongue of the Al-washah , The muwashshah is a poetic art that appeared in Andalusia after the Arabs entered it ,characterized by special system It differs from the traditional Arabic poem, as it has a beginning represented in the beginning of the muwashshah and several equal parts ending with differentrhymes. The Al-washah ends his speech with fragments called al-Kharja, which have special rhymes and are written in the classical Arabic, colloquial or Spanish. The topic of my research focuses on the publications written in Spanish, which were the focus of the attention of orientalists and Arab researchers.
In this paper, the 5 minutes measured wind speed data for year 2012 at 10 meter height for Tweitha have been statically analyzed to assess the time of wind turbine electrical power generation. After collection Tweitha wind data and calculation of mean wind speed the cumulative Weibull diagram and probability density function was ploted, then each of cumulative Weibull distribution, cut-in and furling turbine wind speed could be used as a mathematical input parameters in order to estimate the hours of electrical power generation for wind turbine during one day or one year. In Tweitha site, found that the average wind speed was (v= 1.76 m/s), so five different wind turbines were be selected to calculate hours of electrical generation for A
... Show MoreHydrochemical study of groundwater has carried out for the Al-Khassa Sub-Basin during the October 2020 and May 2021 seasons for estimating the impacts of seasonal variation and human activity on water quality and using the isotope to determine the main source of recharge. It was found that Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), and Dissolved Oxygen (DO) were out of the standard indicating that the groundwater environment was reduced and difficult to recover from pollution. Physical and chemical properties that were high (Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Electrical conductivity (EC), Total Hydrocarbon (THC)). Partial pollution by nitrate and phosphorous due to the use of
... Show More60 cases of Bacteremia were documented at Ibn Al-Baladi hospital during 6 months (1-1-2002 to 1-7-2002), with an incidence of 5.2 were gram-negative organisms and most common one was Salmonella and Klebsiella. Incidence was significantly higher in male than female .Antimicrobial sensitivity tests revealed that isolated bacteria are with multiple drug resistance to commonly used antimicrobial agents. Salmonella showed high resistance to cephaloxin, co-trimoxazole and amoxicillin and also Klebsiella showed resistance to cephaloxin and amoxicillin.
There is a great operational risk to control the day-to-day management in water treatment plants, so water companies are looking for solutions to predict how the treatment processes may be improved due to the increased pressure to remain competitive. This study focused on the mathematical modeling of water treatment processes with the primary motivation to provide tools that can be used to predict the performance of the treatment to enable better control of uncertainty and risk. This research included choosing the most important variables affecting quality standards using the correlation test. According to this test, it was found that the important parameters of raw water: Total Hardn
Objective: To assess mothers' knowledge and practices concerning cholera and their relationship with some
sociodemographic characteristics of those mothers.
Methodology: A sample of (100) mother was selected through a convenience sample for the period of July First
through August 31 2007 '؛
. Data were collected through interview of mothers were visiting PHC centers by using
of constructed questionnaire developed by the researcher that contains (31) item. Reliability and Validity of the
tool were determined through pilot study. A descriptive and inferential statistical approaches were used for data
analysis.
Results: The study indicated that mothers’ knowledge and practices concerning cholera were unacceptable
Water quality assessment offers a scientific basis for water resource development and management. This research aims to assessment of Al-Rustamiya sewage treatment plant depending on annually changes and produces maps that declare changes on parameter during a period (2015-2018). Based on prior Government Department Baghdad Environment data which annually feature changes for samples from Northern Rustamiya have been estimated as a working model. Drawn a map of the Diyala River shows annual changes in the characteristics of the Diyala River, based on northern and southern Rustamiya effluent samples, and Diyala River samples. The characteristics that research focused on were biochemical
This study is aimed to Green-synthesize and characterize Al NPs from Clove (Syzygium aromaticum
L.) buds plant extract and to investigate their effect on isolated and characterized Salmonella enterica growth.
S. aromaticum buds aqueous extract was prepared from local market clove, then mixed with Aluminum nitrate
Al(NO3)3. 9 H2O, 99.9% in ¼ ratio for green-synthesizing of Al NPs. Color change was a primary confirmation
of Al NPs biosynthesis. The biosynthesized nanoparticles were identified and characterized by AFM, SEM,
EDX and UV–Visible spectrophotometer. AFM data recorded 122nm particles size and the surface roughness
RMs) of the pure S. aromaticum buds aqueous extract recorded 17.5nm particles s
In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm−2), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re