Preferred Language
Articles
/
IBd-QI8BVTCNdQwCBmd_
MATTER IN THE BEAM: WEAK LENSING, SUBSTRUCTURES, AND THE TEMPERATURE OF DARK MATTER
...Show More Authors
ABSTRACT<p>Warm dark matter (WDM) models offer an attractive alternative to the current cold dark matter (CDM) cosmological model. We present a novel method to differentiate between WDM and CDM cosmologies, namely, using weak lensing; this provides a unique probe as it is sensitive to all of the “matter in the beam,” not just dark matter haloes and the galaxies that reside in them, but also the diffuse material between haloes. We compare the weak lensing maps of CDM clusters to those in a WDM model corresponding to a thermally produced 0.5 keV dark matter particle. Our analysis clearly shows that the weak lensing magnification, convergence, and shear distributions can be used to distinguish between CDM and WDM models. WDM models <italic>increase</italic> the probability of weak magnifications, with the differences being significant to ≳5<italic>σ</italic>, while leaving no significant imprint on the shear distribution. WDM clusters analyzed in this work are more homogeneous than CDM ones, and the fractional decrease in the amount of material in haloes is proportional to the average increase in the magnification. This difference arises from matter that would be bound in compact haloes in CDM being smoothly distributed over much larger volumes at lower densities in WDM. Moreover, the signature does not solely lie in the probability distribution function but in the full spatial distribution of the convergence field.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of certain radiomorphometric facial indices in different facial types of Iraqi adults using Cone Beam Computed Tomography
...Show More Authors

Background: The human face has its special characteristics. It may be categorized into essentially three kinds in horizontal and vertical directions: short or brachyfacial, medium or mesofacial and long or dolichofacial. The aim of this study was to describe several orofacial indices and proportions of adults, according to gender in Iraqi subjects by using cone beam computed tomography . materials and methods: This prospective study included 100 Iraqi patients (males and females) ranging from 20 to 40 years. All subjects attended the Oral and Maxillofacial Radiology Department of Health Specialist Center for Dentistry in AL Sadr city in Baghdad taking cone beam computed tomography scan for different diagnostic purposes from October 2016 to

... Show More
View Publication
Crossref
Publication Date
Fri Dec 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Sagittal Condylar Position of TMJ Dysfunction in Centric Occlusion by Using Cone Beam Computed Tomography
...Show More Authors

Background: Temporomandibular joint (TMJ) is a compound articulation formed from the articular surfaces of the temporal bone and the mandibular condyle.CBCT imaging of TMJ is that it allows accurate measurements of the volume and surface of the condyle. The aim of the study is to assess the sagittal position of mandibular condyle in patients with temporomandibulardysfunction using Cone Beam Computed Tomography in centric occlusion. Materials and Methods: CBCT images for all patients were obtained in an upright position using New Tom Giano CBCT with different field of view (11 x 8), (11 x 5), and (8 x 8) and exposure factors was changed accordingly using NNT version 5.1 software for sagittal reconstruction, anterior, superior and posterior

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EFFCT OF HOOPS AND COLUMN AXIAL LOAD ON SHEAR STRENGTH OF HIGH-STRENGTH FIBER REINFORCED BEAM-COLUMN JOINTS
...Show More Authors

A reinforced concrete frame is referred as "RIGID FRAMES". However, researches indicate that the Beam-Column joint (BCJ) is definitely not rigid. In addition, extensive research shows that failure may occur at the joint instead of in the beam or the column. Joint failure is known to be a catastrophic type which is difficult to repair.
This study was carried out to investigate the effect of hoops and column axial load on the shear strength of high-strength fiber reinforced Beam-Column Joints by using a numerical model based on finite element method using computer program ANSYS (Version 11.0). The variables are: diameter of hoops and magnitude of column axial load.
The theoretical results obtained from ANSYS program are in a good a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Crestal Bone Resorption around Dental Implants in Flapped and Flapless Surgical Techniques Depending on Cone Beam CT Scan (Comparative Study)
...Show More Authors

Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Physica E: Low-dimensional Systems And Nanostructures
In-situ lattice structure analysis in sp2 hybridization of stable carbon isotopes: Precision modelling of temperature
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Fuel
Effect of temperature and SiO2 nanoparticle size on wettability alteration of oil-wet calcite
...Show More Authors

Nanofluid treatment of oil reservoirs is being developed to enhance oil recovery and increase residual trapping capacities of CO2 at the reservoir scale. Recent studies have demonstrated good potential for silica nanoparticles for enhanced oil recovery (EOR) at ambient conditions. Nanofluid composition and exposure time have shown significant effects on the efficiency of EOR. However, there is a serious lack of information regarding the influence of temperature on nanofluid performance; thus the effects of temperature, exposure time and particle size on wettability alteration of oil-wet calcite surface were comprehensively investigated; moreover, the stability of the nanofluids was examined. We found that nanofluid treatment is more efficie

... Show More
Scopus (157)
Crossref (150)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of The College Of Basic Education
Effect of annealing temperature on Structural and Optical properties of amorphous Selenium thin films
...Show More Authors

Publication Date
Sun Nov 19 2017
Journal Name
Iraqi Journal Of Laser
Sulfur Hexafluoride (SF6) Trace Gas Sensing using Modulated CO2 Laser Beam
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Buckling Behavior of Aluminum Alloy Thin-Walled Beam with Holes under Compression Loading
...Show More Authors

Thin-walled members are increasingly used in structural applications, especially in light structures like in constructions and aircraft structures because of their high strength-to-weight ratio. Perforations are often made on these structures for reducing weight and to facilitate the services and maintenance works like in aircraft wing ribs. This type of structures suffers from buckling phenomena due to its dimensions, and this suffering increases with the presence of holes in it. This study investigated experimentally and numerically the buckling behavior of aluminum alloy 6061-O thin-walled lipped channel beam with specific holes subjected to compression load. A nonlinear finite elements analysis was used to obtain the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref