Determining risk indicators for dental implants is an essential strategy for preventing peri-implant diseases and effective diagnosis of dental implant success. To investigate the impact of certain potential factors on the osseointegrated dental implant. Eighty-four individuals were included in our study, 50 cases as a patient’s group and 34 participants as a control group. All cases were diagnosed based on certain criteria, 30 (60%) of patients had peri-implantitis, 20 (40%) with severe periimplantitis, 36(72%) were generalized, and 15 (30%) as localized peri-implantitis cases. The study has indicated that 44.7% of dental implants were in the anterior maxilla, followed by (27.3%) posterior maxilla, (17.4%) posterior mandible, and (10.4%) anterior mandible. Also results were showed that the anterior maxilla was significantly the highest (P=0.000) in the incidence of PID than any other implantation sites (PMx, PMa, AMa). The most patients’ complaint was 28(56%) altered gingival appearance, followed by 20(40%) pathological mobility, 16(32%) halitosis, 16(32%) pain, 12(28%) bleeding, 8(16%) unpleasant taste. The majority of the implants in both groups were long, regular-width, conical and had a rough surface In the patient group, all risk indicators related to implant design were showed a significantly higher than the control group, except for regular-width and screw type implant, which were significantly lower than control. In conclusion, the study improved that many different potential risk indicators contributed to the development of PIDs.
This present study demonstrated that liver was involved in 14 %of typhoid patients manifesting with hepatomegaly. Elevation of serum enzymes in typhoid fever was presumably of a muscular origin, while elevation of liver enzyme was relatively less common. This study was performed on 30 female patients diagnosed by ultrasound (US) of abdomen, with paratyphoid A, ranged between (20-40) years compared with 30 healthy control .Patients volunteers were treated with appropriate antibiotics for 14 days and investigations were repeated 2-3 week after completion of treatment. Patients had clinical and biochemical evidence of hepatic dysfunction. The spectrum of hepatic involvement included hepatomegaly , jaundice, derangement of various hepatic func
... Show MoreThe capital banking foundation stone upon which the bank in the practice of business activities, the more capital a good financial adequacy of the increased bank's ability to grant credit and expand the various activities and provide a safety element for depositors and other sources of funding to achieve profits and increase the trading volume of the shares, causing the rise the rate of return for the shares of banks and have the Central Bank as head of the banking system by issuing instructions capital increase banking, according to the requirements of economic development and increase gross domestic product by supporting investment projects that are financed through banks, the research aims to show the extent of the banks commitment to
... Show MoreBuffering of Local anaesthesia (LA) has been suggested as a mechanism to improve injection comfort and hasten the onset of anaesthesia. Aim This study aimed to evaluate the effectiveness of buffered LA in the extraction of maxillary premolars and molars. Materials and Methods This randomized controlled study included 100 patients who were indicated for extraction of maxillary posterior teeth, they were randomly divided into two groups; a study group that received infiltration of buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA, and a control group that received non-buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA. The buffering was performed using the Onset® LA buffering system (Onpharma®). The outcome va
... Show MoreBackground: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o
... Show MoreAbstract
The objective of this research is to identify the analysis of the ethics of the administration in the development of the social responsibility of one government organizations, and to achieve the objectives of the research was the use of a questionnaire developed for the purpose of data collection and distribution to the research sample, was chosen as a total sample population (50) individuals were relying on statistical package to do a statistical analysis for this research, user, ANSI (SPSS) simple regression analysis, standard deviation, Pearson correlation coefficient.
Research findings show the role of social responsibility in achieving the university's strategy,
... Show MoreDensity functional theory calculations are employed to investigate the impact of edifenphos molecule on the reactivity and electronic sensitivity of pure calcium oxide (CaO) nanocluster. The strong adsorption of edifenphos molecule on CaO nanocluster occurs by the sulfur head of the adsorbate, and the amount of the energy of this adsorption is around − 84.40 kcal/mol. The adsorption of edifenphos molecules results in a decrease in the values of Eg of CaO from 4.67 to 3.56 eV, as well as an increase in the electrical conductance. Moreover, the work function of CaO nanocluster is significantly affected, which changes the current of the field emission electron. Eventually, the recovery time is calculated around 99 ms at ambient temperature f
... Show MoreThe research aims to get acquainted with the evaluation of the reality of the application of the curriculum axis from among the eight Iraqi academic accreditation standards in a sample of governmental and private universities and colleges in Iraq and to identify the main and secondary reasons for it as well as to provide proposed mechanisms and procedures to help reduce gaps, If the research problem is represented in the weak availability of the requirements of the curriculum axis in universities and colleges (the study sample) due to the weak documentation and successful implementation of them and interest in them is still below the level of ambition, In order to arrive at scientific facts, the researchers adopted the comparativ
... Show MoreBackground: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant with living bone and modification of the implant surface could enhance osseointegration. This study was aimed to investigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dental implants. Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groups to study the effect of different duration of heat treatment to the surface topography; surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated to evaluate the effect of different durations of
... Show MoreBackground/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-
... Show More