Preferred Language
Articles
/
HxeIaI8BVTCNdQwCuHe8
Effect of Gamma Radiation and Borax on Mechanical Properties of Polyvinyl Alcohol and Chitosan Blend Film
...Show More Authors

The creation and characterisation of biodegradable blend films based on chitosan and polyvinyl alcohol for application in a range of packaging is described. The compatibility between the chitosan and PVA polymers was good. Composite films had a compact and homogeneous structure, according to the morphology analysis. The mechanical test result of PVA/CH at concentrations 5% showed, that The higher values of TS recorded in sample (p1, with 40 MPa) while the lower values appeared in sample (p9, with 22.09 MPa), the TS decreased gradually as the amount of PVA increased in blend film. While the blend film of pure Chitosan exhibits a poor mechanical strength which makes it a poor candidate for packaging but Blending CH with PVA together improved tensile strength. PVA/CH at concentrations 10%. Showed the higher TS values appeared in sample (C1 with 36.64MPa) while the lower values of TS appeared in sample (C9 with 24.4 MPa). In comparison with pure PVA have the lower TS than all blend film. The result of mechanical properties after addition of borax solution revealed that the Borax improves the E at max and TS of blend films. Mechanical properties results of CH/PVA/Tio2, Showed that the TS and E at max were increased after introducing of Tio2 into the polymer matrix. The P1 sample have been chosen according to their possess acceptable TS, E at max to be subjected to gamma radiation at different doses 2.3, 3.5, 4.5, 6, 7.5 kGy. The results demonstrated, that the increasing the radiation doses lead to increasing in TS of blend film, following increasing in E at max, the highest TS of the irradiated films is observed at 7.5.kGy dose.

Scopus Crossref
View Publication
Publication Date
Wed Jul 19 2017
Journal Name
International Journal Of Advances In Chemical Engineering And Biological Sciences
Detection of Aflatoxin M1 in Pasteurized Canned Milk and Using of UV Radiation for Detoxification
...Show More Authors

The current study was designed to investigate the presence of aflatoxin M1 in 25 samples of pasteurized canned milk which collected randomly from some Iraqi local markets using ELISA technique. Aflatoxin M1 was present in 21 samples, the concentration of aflatoxin M1 ranged from (0.25-50 ppb). UV radiation (365nm wave length) was used for detoxification of aflatoxin M1 (sample with highest concentration /50 ppb of aflatoxin M1 in two different volumes ((25 & 50 ml)) for two different time (15 & 30 min) and 30, 60, 90 cm distance between lamp and milk layer were used for this purpose). Results showed that distance between lamp and milk layer was the most effective parameter in reduction of aflatoxin M1, and whenever the distance increase the

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Synthesis and Characterization of Multishapes of Fe3O4 Nanoparticle by Solve-Hydrothermal Method Using Microwave Radiation
...Show More Authors

Iron oxide(Fe3O4) nanoparticles of different sizes and shapes were synthesized by solve-hydrothermal reaction assisted by microwave irradiation using ferrous ammonium sulfate as a metal precursor, oleic acid as dispersing agent, ethanol as reducing agent and NaOH as precipitating agent at pH=12. The synthesized Fe3O4 nano particles were characterized by X-ray diffraction (XRD), FTIR and thermal analysis TG-DTG. Sizes and shapes of Fe3O4 nanoparticles were characterized by Scanning Electron Microscopy (SEM), and atomic force microscopy (AFM).

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Improvement of the surface hardness and wear resistant of low carbon steel using laser radiation
...Show More Authors

0

View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Measurement of background radiation, cosmic ray flux and their hazard parameter of Baghdad city districts
...Show More Authors

The aim of this work was directed to measure the cosmic ray (CR)
flux and the background (BG) absorbed dose rate for districts of
Baghdad city. The maximum values of CR flux was 2.01
(particle/cm2.s) registered for several Baghdad districts and the
minimum was 0.403 (particle/cm2.s) belonging to Al-kadhimiya
district, whereas the overall average value was 1.24 (particle/cm2.s).
The BG measurements showed that the maximum absorbed dose was
25 nSv/h belonging to Noab AL-Dhbat district and the minimum
absorbed was 19.01 nSv/h observed in Al-Ghadeer district, while
the overall average was 22.56 nSv/h, and this value is small than the
Iraqi permissible limit, which is restricted by Iraqi Center of
Radiation Pr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jul 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of addition of untreated and oxygen plasma treated polypropylene fibers on some properties of heat cured acrylic resin
...Show More Authors

Background: The polymethyl methacrylate is the most reliable material for the construction of complete and partial dentures, despite satisfying esthetic demand itsuffered from having unsatisfactory properties like impact strength and transverse strength. This study was designed to improve the impact strength and transverse strength of heat cure acrylic resin by adding untreated and oxygen plasma treated polypropylene fibers and investigate the effect of this additive on some properties of acrylic resin materials. Materials and methods: Untreated and oxygen plasma treated polypropylene fibers was added to PMMA powder by weight 2.5 %. Specimens were constructed and divided into 5 groups according to the using tests; each group was subdivided

... Show More
View Publication Preview PDF
Publication Date
Mon May 20 2024
Journal Name
Iraqi Journal Of Applied Physics
Effect of Thermal Neutron Radiation Dose on Density of Local and Extended Energy States in Se<inf>55</inf>S<inf>20</inf>Sb<inf>15</inf>Sn<inf>10</inf> Alloy
...Show More Authors

Four samples of the Se55S20Sb15Sn10 alloy were prepared using the melting point method. Samples B, C and D were irradiated with (6.04×1010, 12.08×1010 and 18.12×1010 (n.cm-2s -1 ) of thermal neutron beam from a neutron source (241Am-9Be) respectively, while sample A was left not irradiated. The electrical properties were assessed both before and after the radiation. All irradiated and non-irradiated samples show three conduction mechanisms, at low temperatures, electrical conductivity is achieved by electron hopping between local states near the Fermi level. At intermediate temperatures, conduction occurs by the jumping of electrons between local states at band tails. At high temperatures, electrons transfer between extended stat

... Show More
View Publication Preview PDF
Scopus (1)
Scopus
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Measuring the concentrations of natural radioactive isotopes and radiation dose rates for Missan Province
...Show More Authors

This research included measuring the concentrations of natural radioactive isotopes U-238 and Th-232 and radiation dose rates for selected areas of Missan province, GR-460 system was used which has the potential to measure the concentrations of natural radioactive isotopes in (ppm) unit and measuring the radiation dose rates in μR/h unit. It was also used with the system the mobile device FH-40 which measures the radiation dose rates in units μSμ/h the measurement results showed the absence of a significant increase in the U-238 and Th-232 concentration where the concentration of isotopes of U-238 and natural Th-232 (3.35-5.46) ppm respectively it is authorized and universally accepted. In terms of radiation dose rates it ranged betwe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 14 2019
Journal Name
Al-kindy College Medical Journal
Risk Of Cancer And Radiation Dose Received By Patients From Common Diagnostic Radiological Examinations
...Show More Authors

Background: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases.

 Objectives   To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 02 2013
Journal Name
Journal Of The College Of Basic Education
Excess parameters of binary mixtures of tetrahydrofurfuryl alcohol with cyclopentanol and 1-pentanol at (293.15, 303.15 and 313.15 K)
...Show More Authors

Publication Date
Sun May 10 2015
Journal Name
Al-academy
Functionalizing Location's Indications and Aesthetic Elements in Novel Film"(Pianist Film as an example): منير طه سلمان
...Show More Authors

Cinema artist work has not been achieved without location indications ; places are of cultured indications and its effect on behaviors and trends. Location is an important element as to convey meanings via its interaction with the personality about which it has been written may studies. Despite location occupies huge spaces within social and philosophical Drama branches , but it has a strong connection with the art world since it reflects reality of global theories in different fields. Audio and visual speech in Cinema have connected with the environmental effectiveness resulted from location which the sensual understanding interacts with in a way that suits Movie. Location consists of mixing elements of Movie and it in return interacts

... Show More
View Publication Preview PDF
Crossref