This Book is the second edition that intended to be textbook studied for undergraduate/ postgraduate course in mathematical statistics. In order to achieve the goals of the book, it is divided into the following chapters. Chapter One introduces events and probability review. Chapter Two devotes to random variables in their two types: discrete and continuous with definitions of probability mass function, probability density function and cumulative distribution function as well. Chapter Three discusses mathematical expectation with its special types such as: moments, moment generating function and other related topics. Chapter Four deals with some special discrete distributions: (Discrete Uniform, Bernoulli, Binomial, Poisson, Geometric, Negative Binomial and Hypergeometric) with their mathematical formulas of p.m.f., C.D.F. and m.g.f. Chapter Five deals with some special continuous distributions: (Uniform, Normal, Exponential, Gamma and Beta) with their mathematical formulas of p.m.f., C.D.F. and m.g.f. Many solved examples are intended in this book (obtaining mean and variance of distributions by m.g.f.). Chapter Six introduces univariate discrete and continuous transformations, i.e., one dimensional variables and their yielding probability distributions. Chapter Seven devotes to truncation of distributions from left, right or both sides, beside the probability distribution of order statistics. Chapter Eight discusses mathematical features of joint, marginal and conditional distributions, as well as independency via covariance and correlation of bivariate distributions. Chapter Nine deals with some special topics such as getting distribution for some transformation from multidimensional random variables by using moment generating function (m.g.f.) and cumulative distribution function (C.D.F.) Many solved examples (about 100) are intended in this book, in addition to a variety of unsolved relied problems (about 150) at the end of each chapter to enrich the statistical knowledge of our readers.
In this paper, the reliability and scheduling of maintenance of some medical devices were estimated by one variable, the time variable (failure times) on the assumption that the time variable for all devices has the same distribution as (Weibull distribution.
The method of estimating the distribution parameters for each device was the OLS method.
The main objective of this research is to determine the optimal time for preventive maintenance of medical devices. Two methods were adopted to estimate the optimal time of preventive maintenance. The first method depends on the maintenance schedule by relying on information on the cost of maintenance and the cost of stopping work and acc
... Show More In this paper the research represents an attempt of expansion in using the parametric and non-parametric estimators to estimate the median effective dose ( ED50 ) in the quintal bioassay and comparing between these methods . We have Chosen three estimators for Comparison. The first estimator is
( Spearman-Karber ) and the second estimator is ( Moving Average ) and The Third estimator is ( Extreme Effective Dose ) . We used a minimize Chi-square as a parametric method. We made a Comparison for these estimators by calculating the mean square error of (ED50) for each one of them and comparing it with the optimal the mean square
This article deals with estimations of system Reliability for one component, two and s-out-of-k stress-strength system models with non-identical component strengths which are subjected to a common stress, using Exponentiated Exponential distribution with common scale parameter. Based on simulation, comparison studies are made between the ML, PC and LS estimators of these system reliabilities when scale parameter is known.
A mathematical model was proposed to study the microkinetics of esterification reaction of oleic acid with ethanol over prepared HY zeolite catalyst. The catalyst was prepared from Iraqi kaolin source and its properties were characterized by different techniques. The esterification was done under different temperature (40 to 70˚C) with 6:1 for molar ratio of ethanol to oleic acid and 5 % catalyst loading.
The microkinetics study was done over two period of time each period was examined individually to calculate the reaction rate constant and activation energy. The impact of the mass transfer resistance to the reactant was also investigated; two different studies have been accomplished to do this purpose.
&nb
... Show MoreIn the present work experiments were conducted to study the effect of solid loading (1,5 and 9 vol.%) on the enhancement of carbon dioxide absorption in bubble column at various volumetric gas flow rate (0.75, 1 and 1.5 m3/h) and absorbent concentration (caustic soda)( 0.1,0.5 and 1 M ). Activated carbon and alumina oxide (Al2O3) are used as solid particles. The Danckwerts method was used to calculate interfacial area and individual mass transfer coefficients during absorption of carbon dioxide in a bubble column. The results show that the absorption rate was increased with increasing volumetric gas flow rate, caustic soda concentration and solid loading. Mass transfer coefficient and interfac
... Show MoreIn this study, we report a statistical study for the relationship between coronal mass ejections (CMEs) and sunspot number (SSN) that were registered during the period 2008-2017 for the solar cycle 24. SSN was extracted from Sunspot Index and Long-term Solar Observations (SILSO), while CMEs number from observations made by the Large Angle and Spectrometric Coronagraph (LASCO) on board the Solar and Heliospheric Observatory mission (SOHO). The present period was adopted to conduct the investigation and obtain the mutual correlation between SSN and CMEs. The relationship between CME, the speed of halo CME, and partial halo CMEs for solar cycle 24 were studied. The analysis of results indicated that the average speed of halo CMEs is almost
... Show MoreImage quality has been estimated and predicted using the signal to noise ratio (SNR). The purpose of this study is to investigate the relationships between body mass index (BMI) and SNR measurements in PET imaging using patient studies with liver cancer. Three groups of 59 patients (24 males and 35 females) were divided according to BMI. After intravenous injection of 0.1 mCi of 18F-FDG per kilogram of body weight, PET emission scans were acquired for (1, 1.5, and 3) min/bed position according to the weight of patient. Because liver is an organ of homogenous metabolism, five region of interest (ROI) were made at the same location, five successive slices of the PET/CT scans to determine the mean uptake (signal) values and its standard deviat
... Show MoreAbstract
The study of oxygen mass transfer was conducted in a laboratory scale 5 liter stirred bioreactor equipped with one Rushton turbine impeller. The effects of superficial gas velocity, impeller speed, power input and liquid viscosity on the oxygen mass transfer were considered. Air/ water and air/CMC systems were used as a liquid media for this study. The concentration of CMC was ranging from 0.5 to 3 w/v. The experimental results show that volumetric oxygen mass transfer coefficient increases with the increase in the superficial gas velocity and impeller speed and decreases with increasing liquid viscosity. The experimental results of kla were correlated with a mathematical correlation des
... Show MoreMango fruit is one of the most nutritionally rich fruits with unique flavor, this fruit belonged to family of Anacardiaceae and it is an excellent source of vitamins specially vitamin A, carotene pigments and potassium. In this study the antimicrobial activity of mango seeds extract has been investigated against gram positive bacteria (Staphylococcus aureus and Bacillus spp.) and gram negative bacteria (Pseudomonas aeruginosa and E. coli) and yeast Candida albicans by well diffusion method in nutrient agar and the results were expressed as the diameter of bacterial inhibition zones surrounding the wells, and the antibiofilm of its extracts was observed against Staphylococcus aureus. The seeds extractions prepared by two solvents: 85% eth
... Show More