—Medical images have recently played a significant role in the diagnosis and detection of various diseases. Medical imaging can provide a means of direct visualization to observe through the human body and notice the small anatomical change and biological processes associated by different biological and physical parameters. To achieve a more accurate and reliable diagnosis, nowadays, varieties of computer aided detection (CAD) and computer-aided diagnosis (CADx) approaches have been established to help interpretation of the medical images. The CAD has become among the many major research subjects in diagnostic radiology and medical imaging. In this work we study the improvement in accuracy of detection of CAD system when comb
... Show MoreObjectives: In developing countries like Iraq, diarrhea was responsible for 70% of deaths among pediatrics. This study was designed to determine Iraqi mothers’ knowledge and malpractices associated with diarrhea management in pediatrics.Methods: A cross-sectional pilot study was done on a convenient sample of mothers in Baghdad – Iraq. Data collection was done using a validated questionnaire specifically designed for this study.Result: Most participants preferred to consult physicians or pharmacists about pediatrics diarrhea management. Breastfeeding was stopped by 19% of participants, whereas 35% of mothers who depend on formulated milk discontinued it. Only 30% of participants use oral rehydration solution therapy always as a
... Show MoreThe adsorption of hexavalent chromium by preparing activated carbon from date seeds with zinc chloride as chemical activator and granular date seeds was studied in a batch system. The characteristics of date seeds and prepared activated carbon (ZAC) were determined and found to have a surface area 500.01 m2/g and 1050.01 m2/g , respectively and iodine number of 485.78 mg/g and 1012.91 mg/g, respectively. The effects of PH value (2-12), initial sorbate concentration(50-450mg/L), adsorbent weight (0.004-0.036g) and contact time (30-150 min) on the adsorption process were studied . For Cr(VI) adsorption on ZAC, at 120 min time contact, pH solution 2 and 0.02 adsorbent weight will ach
... Show MoreThe topic of the research dealt with the image of Iraq in the British press based on a sample of the newspapers (The Guardian and the Daily Telegraph), which are among the most important and largest newspapers in the United Kingdom and the world, because of its active role in guiding local and international public opinion towards important issues and events, Since these two newspapers are interested in the accuracy of sensitive political topics, the message aimed at knowing the media image that these two newspapers painted about Iraq in the period that was limited to the first quarter of 2019, and also to know the nature of the contents promoted by these newspapers about the Iraqi reality, The method of content analysis was used as an ap
... Show MorePorous silicon (PS) layers are prepared by anodization for
different etching current densities. The samples are then
characterized the nanocrystalline porous silicon layer by X-Ray
Diffraction (XRD), Atomic Force Microscopy (AFM), Fourier
Transform Infrared (FTIR). PS layers were formed on n-type Si
wafer. Anodized electrically with a 20, 30, 40, 50 and 60 mA/cm2
current density for fixed 10 min etching times. XRD confirms the
formation of porous silicon, the crystal size is reduced toward
nanometric scale of the face centered cubic structure, and peak
becomes a broader with increasing the current density. The AFM
investigation shows the sponge like structure of PS at the lower
current density porous begi
A new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.