This study evaluates 22 patients with retained foreign bodies in the maxillofacial region that were all caused by penetrating missile injuries. Surgical intervention for the retrieval of the foreign bodies was carried out in 20 patients through the existing wounds and through separate incisions; all patients were followed up for a minimum of 2 months during which all the complications were registered and managed. Preoperative imaging is a prerequisite for the accurate localization of the foreign body and the subsequent successful removal of it. All patients developed complications that were categorized in this study into those that result from the injury itself and those that occur because of the retrieval procedure, the latter category being mostly easily managed. In general, all foreign bodies in the maxillofacial region should be removed; the surgeon involved should weigh the benefits and the perils of the removal, and the patient should be well informed about the possibility of the failure of removal of the foreign body.
The role of the climate in the development of the performance of the administrative bodies of sports clubs
Embedded advertisement constitutes a special kind of communication. As it performs many important roles such as giving information, highlighting the value of the product, and urging the target consumer to buy it by influencing his/ her behavior using an attractive manner of mind and conscience. Both cinema and television are the most prominent and powerful advertising media that enjoy the interest of all audiences and capture most of the advertising spending. As advertisers have paid attention to the importance of indirectly incorporating their products into content that the audience loves and is keen to follow, since the actual impact lies in the inclusion of the product within content that the audience appeals to. Hence, this leads to
... Show MoreIntroduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf
... Show MoreImposed on foreign oil companies from important sources in the financing of the general budget in most countries of the world income tax is considered as well as be used to achieve political, economic and social goals, and has developed the concept of the tax until it became play an important role in influencing the economic conditions of a country, and the aim of this research is to statement imposed on foreign oil companies operating in Iraq in the financing of the state budget income tax contribution, as well as clarify the contracts type contracts with these companies, which is in favor of Iraq, together with the Income Tax Law No. (19) for the year / 2010, and instructed No. (5) for the year / 2011, which organized the tax process s
... Show MoreThe tax system in Iraq plays a prominent role in the process of attracting foreign investments to operate the money in the investment market of our country, through the incentives provided by the legal texts that stimulate foreign investors and pay to contract, and those incentives are the tax exemptions and tax obtained by the foreign investor, The Iraqi turned to that issue in the Iraqi investment law currently in force and amended, but we will try to shed light in this study on the extent of those incentives compared to what is granted by the comparative legislation? Is it enough that the legal texts brought by the Iraqi legislator to encourage foreign investor and reassurance of his money through investment in commercial projects wit
... Show MoreThe degree of the woman’s satisfaction on clothing depends, to a large extent, on the body measurements. If clothing is very wide, it shows her enormous and if it is too tight it may draw attention to the defects of the body. It may also lead to the compatibility or incompatibility of clothing with fashion. Whatever the quality of the garment in terms of sewing and design, the costume which is not suitable for body size may affect the physical style negatively and may give the wearer an improper look. Clothing was carried out without measurements and did not use models (templates). The method of preparation affected the overall appearance because it often did not fit the shape of the body completely. Therefore, people thought in many w
... Show MoreBackground: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hosp
... Show MoreBackground: Rheumatoid arthritis is a common chronic and destructive autoimmune arthropathy .Treatment with infliximab gives great improvement to a large numbers of patients with RA ,however, in some patients after prolonged treatment infliximab can induce anti-infliximab antibodies formation and result to loss of infliximab efficacy and active persistent disease.
Objective: to investigate the frequency of anti-infliximab antibodies in Iraqi patients with rheumatoid arthritis.
Patients and methods: fifty Iraqi RA patients(36 females and 14 males) compared with 50 control( 25 healthy control and 25 case control (patients with RA on other treatment) ) were included in this study from begging of March 201
Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show MoreThis study aims to evaluate the biocompatibility of a novel filler material intended to improve the longevity of polymer systems used in prosthetics in respect of cytotoxicity and skin irritation. RTV50F silicone elastomer incorporated with various percentages of hexagonal boron nitride (H-BN) (0.1, 0.3, 0.5, 0.7, and 1 wt%) have been tested. Silicone without H-BN was utilized as the control for comparison. The in vitro cytotoxicity test includes specimens (n=18) with 10 mm in diameter and 2 mm in thickness applied directly to the normal human fibroblast cell line (NHF) and incubated for 72 hours, then 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was used to determine the cell viability. The skin irritati