Preferred Language
Articles
/
HhY5C4sBVTCNdQwCVMcb
Simultaneous electrodeposition of multicomponent of Mn–Co–Ni oxides electrodes for phenol removal by anodic oxidation
...Show More Authors

Electrodeposition of metal oxides on graphite electrodes can improve their ability to remove organic substances. In this work, multicomponent oxides of Mn, Co, and Ni were electrochemically deposited on both the anode and cathode of graphite electrodes to enhance their performance in removing phenol. Formation of the deposit was achieved within 2 h in current densities of 20, 25, 30, and 35 mA/cm2 for better composite properties. The deposited layer was characterized by testing the surface structure, morphology, composition, and roughness. X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), and Atomic force microscopy (AFM) techniques facilitated these tests. The composite electrodes have synthesized with a metal salts concentration, i.e., Co(NO3)2, Ni(NO3)2, and MnCl2 of 0.1 M with a mixing ratio of 1:1:1. The results exhibited a remarkable formation of the deposit on both the anode and cathode of our electrochemical cell. An amorphous skin of Mn–Co–Ni oxide was constituted on the anode, while a crystalline film of Mn–Co–Ni oxide accumulated on the cathode. The effectiveness of composite electrodes was examined at current densities of 40, 60, and 80 mA/cm2, pH values of 3, 4 and 5, and NaCl concentration of 1, 1.5, and 2 g/l with an electrolysis time of 1 h. The results show that the removal efficiency of phenol increases with the increase in current densities and NaCl concentration, while it decreases with increasing of alkalinity. The highest removal occurs at the pH, current density and NaCl concentration of 3, 80 mA/cm2, and 2 g/l. The highest obtained removal efficiency is 99.68% which reflects a tremendously high performance of our multicomponent composite for phenol removal and reducing electrolysis time compared to previous studies.

Scopus Crossref
View Publication
Publication Date
Wed Apr 15 2015
Journal Name
Iraqi Journal Of Science
Removal of Lead and Chromium From Industrial Wastewater by Locally Citrobacter spp. Isolates
...Show More Authors

Biosorption is an effective method to remove toxic metals from wastewaters. In this study biosorption of lead and chromium ions from solution was studied using Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The experimental results showed that optimum grwoth temperature for both bacteria is 30oC and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and Pb for C.freundii, C. kosari and in mixes culture of both bacteria is 58%, 53%

... Show More
Publication Date
Wed Nov 04 2020
Journal Name
Systematic Reviews In Pharmacy
Removal of Brilliant Dyes from its Aqueous Solution by Adsorption on Siliceous Rocks
...Show More Authors

In this study involves removing of Brilliant Dyes, were which (Brilliant Green {BG} and Brilliant Cresyl Blue {BCB}) by using Iraqi Siliceous Rocks Powder (SRP). Adsorption isotherms were studied and the factors which prefer it, like temperature and salt effect, Adsorption isotherms of dyes, Brilliant Cresyl Blue {BCB} was found to be comparable to Langmuir equation according to Giles classification, isotherms dye Brilliant Green {BG} was found to be comparable to Freundlich equation more than dye Brilliant Blue {BCB} according to Giles classification. The adsorption process on this surface (SRP) studied at different temperatures, the results showed that the adsorption of dyes (BCB, BG) on the surface increased with increased temperature (E

... Show More
Preview PDF
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oil Removal from Wastewater of Al-Bezerqan Crude Oil Fields by Air Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jun 18 2014
Journal Name
Desalination And Water Treatment
Removal of zinc from contaminated groundwater by zero-valent iron permeable reactive barrier
...Show More Authors

Scopus (23)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Recovery of Catalyst from Tar Formed in Phenol Production Unit
...Show More Authors

This work was conducted to study the recovery of catalyst and desirable components from tar formed in phenol production unit and more particularly relates to such a method whereby better recovery of copper salts, phenol, benzoic acid and benzoate salts from tar by aqueous acid solution was accomplished.
The effect of solvent type, solvent concentration (5, 10, 15, 20, 25 and 30 wt%), agitation speed (100, 200, 300 and 400 rpm), agitation time (5, 10, 15, 20 and 25 min), temperature (90, 100, 110, 120, 130 and 140 oC) , phase ratio (1/1, 2/1, 3/1, 4/1 and 5/1) and number of extraction (1, 2, 3, 4, and 5) were examined in order to increase the catalyst and desirable components extraction.
Four types of solvent were used; hydrochloric

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Proceeding Bromometric Phenol Assay without Starch Indicator
...Show More Authors

         In this research, we exclude starch indicator preparation,that is  used in official phenol assay method. The liberated iodine, in presence of chloroform, was acting as indicator and titrated with sodium thiosulfate until getting a sharp colorless end point. Similarly, starch was cancelled during both blank and standardization of bromine water solution experiments needed in phenol assay. The results obtained were the same volumes and weights as that achieved using starch with just about 0.03% difference in sample procedure. Finally, this work will enable us to save time, effort, fuel and materials spended in laboratory.

Key word:- Phenol, assay, starch indicator

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
modification of polystyrene co butadiene
...Show More Authors

During this research accomplish some chemical modifications on the Poly for new modified polymers with Kimaaaúah qualities, physical and unexpected new applications that the first of these chemical modifications that was completed is the introduction of a poly styrene butadiene swash and then this group

View Publication Preview PDF
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Molecular Liquids
Application of ionic liquids as co-solvent for oil extraction from desert date
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Chem Tech Research
Synthesis of New Selective Electrodes for the Determination of Metronidazole Benzoate (MNZB) Based on a Molecularly Imprinted Polymer Combined With Poly Vinyl Chloride
...Show More Authors

Publication Date
Mon Feb 15 2021
Journal Name
Systematic Review In Pharmacy
Colorimetric Determination Of Sitagliptin As An Oxidation Derivative Of Ninhydrin
...Show More Authors

A sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and

... Show More
Preview PDF