In the recent decade, injection of nanoparticles (NPs) into underground formation as liquid nanodispersions has been suggested as a smart alternative for conventional methods in tertiary oil recovery projects from mature oil reservoirs. Such reservoirs, however, are strong candidates for carbon geo-sequestration (CGS) projects, and the presence of nanoparticles (NPs) after nanofluid-flooding can add more complexity to carbon geo-storage projects. Despite studies investigating CO2 injection and nanofluid-flooding for EOR projects, no information was reported about the potential synergistic effects of CO2 and NPs on enhanced oil recovery (EOR) and CGS concerning the interfacial tension (γ) of CO2-oil system. This study thus extensively investigates the effect of silica NPs on the γ of CO2/decane system at elevated pressure and temperature to recognise the potential impact of NPs-injection on the future CGS projects. To achieve this, a wide-ranging series of tests have been conducted to reveal the role of hydrophilic and hydrophobic silica NPs on γ of the CO2/oil system. n-decane was utilized as model oil and different amounts of NPs were mixed with the oil phase. Oil-NPs dispersions were formulated using an ultrasonic homogenizer. The γ of the CO2/oil system was measured at different pressures (0.1 to 20 MPa) and temperatures (25 to 70 °C) using a high-pressure temperature optical cell. The γ data were measured using the pendant drop technique via axisymmetric drop shape analysis (ADSA). The results showed that, generally, CO2/oil γ subjected mainly to pressure, temperature, and with less extent to NPs load in the oil phase. γ decreases with increased pressure until reaching a plateau where no more significant decrease in γ was observed. The γ trend with increased temperature, on the other hand, was more completed. No significant impact of temperature on γ was recorded with low pressure (≤ 5 MPa). Similarly, at relatively high pressure (≥ 25 MPa), only a slight variation of IFT with temperature change was recorded. However, for the pressure range from 5 – 25 MPa, IFT was increased remarkably with temperature. Furthermore, NPs in the oil phase exhibit a remarkable influence on IFT. In this context, the presence of hydrophilic silica NPs in the oil phase can significantly reduce the γ of the CO2/decane system. However, hydrophobic silica NPs showed less influence on IFT reduction. The outcomes of this work afford good understandings into applications of NP for EOR and CGS applications and help to de-risk CO2-geological storage projects.
A perturbed linear system with property of strong observability ensures that there is a sliding mode observer to estimate the unknown form inputs together with states estimation. In the case of the electro-hydraulic system with piston position measured output, the above property is not met. In this paper, the output and its derivatives estimation were used to build a dynamic structure that satisfy the condition of strongly observable. A high order sliding mode observer (HOSMO) was used to estimate both the resulting unknown perturbation term and the output derivatives. Thereafter with one signal from the whole system (piton position), the piston position make tracking to desire one with a simple linear output feedback controller after ca
... Show MoreProject management are still depending on manual exchange of information based on paper documents. Where design drawings drafting by computer-aided design (CAD), but the data needed by project management software can not be extracted directly from CAD, and must be manually entered by the user. The process of calculation and collection of information from drawings and enter in the project management software needs effort and time with the possibility of errors in the transfer and enter of information. This research presents an integrated computer system for building projects where the extraction and import quantities, through the interpretation of AutoCAD drawing with MS Access database of unit costs and productivities for the pricing and
... Show MoreCobalt substituted nickel copper ferrite samples with general formula Ni0.95-xCoxCu0.05Fe2O4, where (x= 0.00, 0.01, 0.02, 0.03, 0.04 and 0.05) were prepared by solid-state reactions method at 1373 K for 4h. The samples prepared were examined by X-ray diffraction (XRD(, atomic force microscope (AFM), Fourier transform infra-red spectroscopy (FTIR) and Vickers hardness. X-ray diffraction patterns confirm the formation of a single phase of cubic spinel structure in all the prepared samples . XRD analysis showed that the increase in the cobalt concentration causes an increase in the lattice constant, bulk density (ρm) and the x-ray density (ρx), whereas porosity (p) and crystallite size (D) decrease. The Topography of the surface observed
... Show MoreThe study aimed to reveal the role of social capital represented by its dimensions (structural, relational, and cognitive) in strengthening the management of excellence in Azadi Hospital / Duhok. In order to reach the goal of the study, the study variables were highlighted in theory through framing concepts and literary contributions for researchers in this field, In the field, the questionnaire was used as a basic tool to collect data from the individuals in the research sample who were represented by officials and individuals working from administrators and technicians, as (120) forms were distributed to the respondents, and (110) were retrieved from them in a way that is valid for analysis. Several statistical methods have bee
... Show MoreThis study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu
... Show MoreA characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.
This study has aimed to measure the relationship between the skills required for the labor market and the employment of graduates of community colleges at King Khalid University. For gathering the required data, a questionnaire has been designed and distributed to the faculty members of community colleges at King Khalid University in a random sample method. The chosen sample size has covered (123) individuals. Questionnaire forms have been distributed and retrieved from (117) participants. Therefore, the estimated response has reached 95 % of the total sample size. The results of the study have shown that there is not any significant relationship between the skills which the graduates acquire and the requirements of employmen
... Show MoreAn experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show More