Preferred Language
Articles
/
HRfVbo8BVTCNdQwClnjb
A STUDY OF SOME TECHNICAL AND ECONOMICAL PARAMETERS FOR MACHINERY UNIT (NEW HOLLAND &DISC PLOW) BY USING THREE DIFFERENT TILT ANGLES دراسة بعض المؤشرات الفنية والأقتصادية للوحدة الميكنية (الجرار نيوهولاند مع المحراث القرصي الثلاثي القلاب) بأستخدام زوايا ميل مختلفة للأقراص
...Show More Authors

Publication Date
Wed Jun 01 2022
Journal Name
Journal Of Nursing Education
Compassion Competence Among Nursing Students From Different Cultures: A Multinational Study
...Show More Authors
Background:

Compassion competence is a nurse's ability to provide patient-centered care and communicate with patients in a sensitive and insightful manner. This descriptive cross-sectional survey study aimed to assess the compassion competence of a multinational group of nursing students.

Method:

A total of 1,158 undergraduate nursing students participated in this study, and stratified random sampling method was used to select participants from the 100 study level to the 400 or 500 level. Data were collected using the Compassion Competence Scale.

<
... Show More
View Publication
Scopus (7)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Dec 31 2023
Journal Name
Azerbaijan Pharmaceutical And Pharmacotherapy J
Prevalence and Contributed Factors for Varicose Veins in Intensive Care Unit Nurses at Baghdad Teaching Hospitals
...Show More Authors

Background: Varicose vein (VV) is a common problem that mostly occurs in legs. This medical condition can influence the quality of life and working condition of nurses. Aim of the study: To estimate the prevalence of lower limbs varicosity and its associated risk factors among nurses. Methods: This a cross-sectional descriptive study was carried out among 100 nurses working Baghdad Teaching Hospital, Surgical Specialties Hospital, and Al- Kidney Teaching Hospital, Baghdad, Iraq from January 1st to May 10th, 2022. The participants were recruited in the study using systematic random sampling. The Occupational Sitting and Physical Activity and Aberdeen Varicose Vein Questionnaires were used for data gathering. Results: The prevalence o

... Show More
View Publication
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The effect of triggering on the output performance of diode direct face pumping for disc laser in pulse mode
...Show More Authors

The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
A new achromatic glass for near infrared laser instruments
...Show More Authors

This research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 02 2024
Journal Name
Advances In Systems Science And Applications
A New Face Swap Detection Technique for Digital Images
...Show More Authors

View Publication
Scopus
Publication Date
Thu Dec 01 2011
Journal Name
Proceedings Of 2011 International Conference On Computer Science And Network Technology
A new proposed handoff scheme for mobile communication systems
...Show More Authors

There are many studies dealt with handoff management in mobile communication systems and some of these studies presented handoff schemes to manage this important process in cellular network. All previous schemes used relative signal strength (RSS) measurements. In this work, a new proposed handoff scheme had been presented depending not only on the RSS measurements but also used the threshold distance and neighboring BSS power margins in order to improve the handoff management process. We submitted here a threshold RSS as a condition to make a handoff when a mobile station moves from one cell to another this at first, then we submitted also a specified margin between the current received signal and the ongoing BS's received signal must be s

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Some Immunological Parameters Paraw in Women with vaginal candidiasis
...Show More Authors

This study was conducted to know some Immune responses in women with vaginal candidias is by Candidia species. Hemoglubin (Hb) was decreased significantly in patient women comparing with control group. The differential count of Blood cells revealed that neutrophils and monocytcs were increased significantly in patient women comparing with control group. The percentage of the Phagocytosis index was decreased significantly in patient women (66.45 + 15.05) comparing with control group (73.72 + 3.77) and the T- lymphocytes were decreased also in patient women (57.75 + 18.787) comparing with control group (74.25 + 7.759).

View Publication Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Using Truncated Test for Finding the Parameters of Single Sampling Plan under Distribution of Log-Logistic
...Show More Authors

A group of acceptance sampling to testing the products was designed when the life time of an item follows a log-logistics distribution. The minimum number of groups (k) required for a given group size and acceptance number is determined when various values of Consumer’s Risk and test termination time are specified. All the results about these sampling plan and probability of acceptance were explained with tables.

View Publication Preview PDF
Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF