Preferred Language
Articles
/
HRfIYo8BVTCNdQwCFHU6
The Effect of Hand Blood Flow on the Peripheral Fingertip Plethysmographic Waveforms Morphology and Pulse Wave Velocity
...Show More Authors

Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left hand remained static. The pulse width, time to peak (TTP), the time to the maximum slope (TTMas) were computed from 30sec DPW signals at three positions of the right hand with regard to heart level, i.e. 35 cm above heart level (+35 cm), at the level of the heart (0 cm), and 35 cm below the level of the heart (-35 cm). DPW characteristics were found to alter with hand position. On lowering the hand to -35 cm relative to heart level, DPW width from the middle finger increased by (6%), but lowering the arm decreased the TTP (by 11 %), TTMas (by 18 %). These changes in time-dependent DPW indices may be attributed to changes in hydrostatic pressure and the venoarterial reflex that changes the blood vessels filling from completely filled one at -35 cm due to arterial vasoconstriction and decreased venous return to partially emptied blood vessels due to arterial vasodilatation and increased venous return at +35 cm. It was assumed that these time-dependent morphological DPW indices alterations were controlled by changes in downstream venous resistance rather than arterial or arteriolar, resistance. Keywords: photo plethysmography, hand elevation, vasoconstriction, vasodilation, vascular mechanics

Crossref
View Publication
Publication Date
Sat Aug 31 2024
Journal Name
International Review On Modelling And Simulations (iremos)
Prosthetic Hand: a Brief Survey of Design and Actuation Technologies
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue May 01 2012
Journal Name
Journal Of Engineering
Study on wind loads coefficients and flow field characteristics around the parabolic trough with stiffeners
...Show More Authors

wind load coefficient

Publication Date
Tue Jul 01 2025
Journal Name
Iranian Journal Of Veterinary Medicine
Aryl Hydrocarbon Receptor Modulation Impacts on the Blood-testis Barrier Integrity via TJP1 Function
...Show More Authors

Background: Male infertility is a global concern and it tends to increase due to miscellaneous factors, such as environmental toxins and genetic and lifestyle choices. The aryl hydrocarbon receptor (AHR) has recently attracted attention due to its involvement in male infertility mechanisms and impact on sperm production and function. AHR, a versatile receptor expressed in various tissues, including the testes, regulates the genes involved in spermatogenesis. AHR activation is associated with cell cycle regulation and chromatin condensation during spermatogenesis. Objectives: This study aimed to investigate the influence of AHR activation on blood-testis barrier (BTB) integrity, focusing on the role of tight junction protein-1 (TJP1)

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Experimental Study on Heat Transfer and Flow Characteristics in Subcooled Flow Boiling in a Microchannel
...Show More Authors

The current study presents an experimental investigation of heat transfer and flow characteristic for subcooled flow boiling of deionized water in the microchannel heat sink. The test section consisted of a single microchannel having 300μm wide nominal dimensions and 300μm height (hydraulic diameter of 300μm). The test section formed of oxygen-free copper with 72mm length and 12mm width. Experimental operation conditions spanned the heat flux (78-800) kW/m2, mass flux (1700 and 2100) kg/m2.s at 31˚C subcooled inlet temperature. The boiling heat transfer coefficient is measured and compared with existing correlations. Also, the experimental pressure drop is measured and compared with microscale p

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Evaluation of the one electron expectation values for different wave function of Be atom
...Show More Authors

The aim of this work is to evaluate the one- electron expectation value from the radial electronic density function D(r1) for different wave function for the 2S state of Be atom . The wave function used were published in 1960,1974and 1993, respectavily. Using Hartree-Fock wave function as a Slater determinant has used the partitioning technique for the analysis open shell system of Be (1s22s2) state, the analyze Be atom for six-pairs electronic wave function , tow of these are for intra-shells (K,L) and the rest for inter-shells(KL) . The results are obtained numerically by using computer programs (Mathcad).

View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Developing a Prosthesis Design using A Gearbox to Replicate the Human Hand Mechanism
...Show More Authors

Prosthetic is an artificial tool that replaces a member of the human frame that is  absent because of ailment, damage, or distortion. The current research activities in Iraq draw interest to the upper limb discipline because of the growth in the number  of amputees. Thus, it becomes necessary to increase researches in this subject to help in reducing the struggling patients.  This paper describes the design and development of a prosthesis for people able and wear them from persons who have amputation in the hands. This design is composed of a hand with five fingers moving by means of a gearbox ism mechanism. The design of this artificial hand has 5 degrees of freedom. This artificial hand works based on the principle of &n

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Ground State Structure of Helium and Phosphorus Isotopes using the Radial Wave Functions of Harmonic-Oscillator and Hulthen Potentials
...Show More Authors

     The ground state density distributions and electron scattering Coulomb form factors of Helium (4,6,8He) and Phosphorate (27,31P) isotopes are investigated in the framework of nuclear shell model. For stable (4He) and (31P) nuclei, the core and valence parts are studied through Harmonic-oscillator (HO) and Hulthen potentials. Correspondingly, for exotic (6,8He) and (27P) nuclei, the HO potential is applied to the core parts only, while the Hulthen potential is applied to valence parts. The parameters for HO and Hulthen are chosen to reproduce the available experimental size radii for all nuclei under study. Finally, the CO component of electron scattering charge form factors are also investigated. Unfortunately, there is no

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Jan 04 2024
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of material flow cost accounting in reducing the cost of products - an applied study in Diyala State Company
...Show More Authors

Abstract

              The current research sought to demonstrate the effect of material flow cost accounting on reducing products through the application of material flow cost accounting technique, which works on the optimal utilization of materials and energy and the reduction of environmental impacts.The research aims to clarify the knowledge foundations for material flow cost accounting, in addition to studying the material flow cost accounting technique that helps reduce the cost of products and make them environmentally friendly. To achieve this, the research relied on the descriptive approach with regard to the theoretical aspect of the resea

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Surgical Case Reports
A rare variant of mirror hand deformity
...Show More Authors

Congenital hand and forearm anomalies pose a unique challenge in plastic and pediatric surgery. We present a case report of an 8- months-old girl with a congenital left sided hand and forearm anomaly, provisionally diagnosed as atypical left mirror hand anomaly. Classically there is absence of radius and duplication of ulna; however, our case had normal radius and ulna and a hand with seven digits arranged in two groups. We did a surgery which involved a ray amputation of the finger ulnar to the most radial digit, aiming to preserve an adequate first web space to reconstruct the thumb. The result of the surgical treatment in both functional and cosmetic aspects was, in authors’ opinion, good.

Publication Date
Sun Jan 02 2011
Journal Name
Al-khwarizmi Engineering Journal
Biomechanical Concept Design of Artificial Human Hand
...Show More Authors

This work is focused on the design parameters and activity of artificial human finger for seven grips. At first, obtained the ideal kinematics of human fingers motion by analyzing the grips video which were recorded using a single digital camera recorder fitted on a tripod in sagital plane while the hand is moving. Special motion analysis software (Dartfish) the finger joint angles were studied using the video recording. Then the seven grips were modeled using static torque analysis, which calculates the amount of torque applied on the fingers joint grip depending on the results of the kinematic analysis. The last step of the work was to design the actuator (Muscle Wire) of artificial finger for the seven grips in a simple design approac

... Show More
View Publication Preview PDF